Laserfiche WebLink
I <br />WINDOW TRIM DETAIL <br />SCALE: 3/4"=1'-0" <br />WINDOWSILL DETAIL <br />SCALE: 3/4"=1'-0" <br />1'-10" <br />SCORED <br />RAISED <br />BAND <br />FOAM PANEL DETAIL <br />SCALE: 3/4"=1'-0" <br />12 <br />5 <br />35 SH <br />[6068 SGD <br />REAR ELEVATION <br />SCALE: 1/4"=1'-0" <br />ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP.) <br />4" WIDE STUCCO BAND (+1) <br />6" FASCIA <br />4" WIDE STUCCO BAND (+1) <br />18" DECORATIVE FOAM <br />SHUTTERS <br />4" WIDE STUCCO <br />BAND (+1) <br />12 <br />5 <br />C EI E7 El IJI E7!' <br />4" WIDE STUCCO <br />16070 GARAGE DOOR <br />FRONT ELEVATION <br />SCALE: 1/4"=1'-0" <br />c n <br />00 <br />j j � -�- �' <br />3068 <br />ROOF SHINGLES PER <br />COMMUNITY SPECS (TYP.) <br />FIN, FLR. <br />BLDG. HEIGHT <br />/— 22"x38" DECORATIVE FOAM <br />PANEL DETAIL <br />�- ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP.) <br />4" WIDE STUCCO BAND (+1) <br />6" FASCIA _ _ T.O. WALL <br />T.O. WINDOW 1, <br />18" DECORATIVE FOAM <br />SHUTTERS <br />�- 4" WIDE STUCCO BAND (+1) - <br />6:12 ROOF SHINGLES PER N o <br />COMMUNITY SPECS (TYP.) A' 00 <br />--4 <br />4" WIDE STUCCO BAND (+1) <br />T.O_2ND FLU _ <br />_ T.O. MASONRY r <br />T <br />00 <br />T.O. WINDOW h <br />4" WIDE STUCCO BAND (+1)) <br />12x12 COLUMN - <br />n <br />4 <br />FIN.FLR.--,-, <br />TI <br />1Lo <br />N <br />PAINT AND FINISH SCHEDULE / KEY <br />PAINT COLOR SCHEME <br />SURFACE TEXTURE / FINISH KEY <br />BODY COLOR <br />TEXTURE <br />FINISH <br />= <br />_..:�:.;; .;•r..;::.: <br />TRIM COLOR <br />SAND <br />FINISH <br />NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE <br />SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, <br />HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, <br />JAMB, HEAD & SILL THE TRIM COLOR. <br />STUCCO INSTALLATION <br />STUCCO AND PORTLAND CEMENT PLASTER SHALL <br />BE INSTALLED PER THE CURRENT ASTM C926 & C1063 <br />REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE <br />STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED <br />OVER METAL OR WIRE LATH AND SHALL NOT BE <br />LESS THAN 2 COATS WHEN APPLIED OVER MASONRY <br />CONTROL JOINTS IN 3-COAT STUCCO SHALL BE USED TO <br />DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. <br />OR AT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTS <br />PER ASTM C1063 (CURRENT EDITION) <br />WEEP SCREED SHALL BE INSTALLED AT ALL <br />STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY <br />AS REQUIRED BY ASTM C 1063 (CURRENT EDITION) <br />- <br />• 4 <br />�d 7 <br />c. <br />, SHUTTER DETAIL <br />SCALE: 3/4"=1'-0" <br />FOAM/POLY <br />NECK TRIM 1 " <br />12" CMU COLUMN, <br />SAND FINISHED <br />STUCCO <br />SQUARE COLUMN DETAIL <br />SCALE: 3/4"=1'-0" <br />W <br />ujuj <br />z0= <br />� 0 >- <br />>o <br />a0 <br />W :D 0 I- <br />U U W ui <br />� Q <br />0-~ <br />1 1 <br />Y01-Z <br />u- 0 0 U) <br />Z Z Z F- Ui <br />Z_ <br />J Q J <br />W D_ = Ir D_ <br />= Z WO U) <br />�I-<Z- <br />Q o <br />O � Q <br />Q <br />O <br />O <br />U) <br />O <br />z <br />0 <br />0 <br />w <br />o <br />w <br />0 <br />I <br />w <br />c?j <br />U) <br />A <br />z <br />o <br />w <br />� <br />w <br />_O <br />tn <br />Ld <br />tn <br />O8 <br />T <br />[a <br />�cj <br />Z <br />aaaaa <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6102 <br />RELEASED: 5/14/20 <br />SHEET <br />A291 <br />