Laserfiche WebLink
0 <br />RAISED <br />WITH SAND FINISH <br />,FOAM MEDALLION DETAIL <br />SCALE: 3/4"=1'-0" <br />GARAGE <br />DOOR <br />4" <br />4" WIDE <br />STUCCO <br />BAND (+1) <br />Ir <br />j <br />u <br />GARAGE TRIM DETAIL <br />SCALE: 3/4"=1'-0" <br />,WINDOW TRIM DETAIL <br />SCALE: 3/4"=1'-0" <br />12 <br />---115 <br />12 <br />5 jr--- <br />ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP.) <br />LL <br />FRO I NO I F-M-1 <br />110 1 ON I <br />ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP.) <br />6" WIDE STUCCO <br />BAND (+1) <br />1'_OII <br />4" WIDE STUCCO <br />BAND (+1) ,,- <br />12 <br />5 r� <br />REAR ELEVATION <br />SCALE: 1 /4"=1'-0" (22 ""x34") <br />SCALE: 1/8"=1'-0" 11 x17") <br />BLDG. HEIGHT <br />ROOF SHINGLES PER <br />8,_0„ ,_0„ COMMUNITY SPECS <br />(TYP.) <br />12 12 4" WIDE STUCCO <br />5 � 5 BAND (+1) <br />o _ _ _ _ _ HEEL_HIGHT <br />c� 4" WIDE STUCCO <br />�] BAND (+1) <br />Fl <br />M <br />EJ T.O. MASONRY `y'T <br />-- -- — -- r <br />T.O. WINDOW c0 <br />-- <br />4" WIDE STUCCO <br />® BAND(+1) <br />18" DECORATIVE <br />FOAM SHUTTERS 00 <br />�t o0 <br />2'-0" STUCCO "25 SH :- <br />BAND RETURN N FIN. FLR. <br />DR. <br />16070 GARAGE 3068 <br />FRONT ELEVATION <br />SCALE: 1/4"=1'-0" (22"x34") <br />SCALE: 1/8"=1'-0" 11 "x17") <br />PAINT AND FINISH SCHEDULE /KEY <br />PAINT COLOR SCHEME <br />SURFACE TEXTURE / FINISH KEY <br />BODY COLOR <br />TEXTURE <br />"7: <br />FINISH <br />ens°•• .:.•..•F•• :r! �`•: <br />SAND <br />TRIM COLOR <br />FINISH <br />NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE <br />SHOWN AROUND WINDOWS &DOORS) INTO THE JAMB, <br />HEAD &SILL OF THE WINDOW &DOORS. PAINT THE BAND, <br />JAMB, HEAD &SILL THE TRIM COLOR. <br />STUCCO INSTALLATION <br />STUCCO AND PORTLAND CEMENT PLASTER SHALL <br />BE INSTALLED PER THE CURRENT ASTM C926 & C 1063 <br />REQUIREMENTS &PROVISIONS OF THE FLORIDA BUILDING CODE <br />STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED <br />OVER METAL OR WIRE LATH AND SHALL NOT BE <br />LESS THAN 2 COATS WHEN APPLIED OVER MASONRY <br />CONTROL JOINTS IN 3-COAT STUCCO SHALL BE USED TO <br />DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. <br />OR AT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTS <br />PER ASTM C1063 (CURRENT EDITION) <br />WEEP SCREED SHALL BE INSTALLED AT ALL <br />STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY <br />AS REQUIRED BY ASTM C1063 (CURRENT EDITION) <br />CC <br />LL cicz <br />) <br />MONco j <br />O <br />0-M adMEMO <br />m< Z <br />i <br />f--FL <br />m <br />U)Ar <br />} <br />>OWCaO <br />W�pF- <br />Q � ?� W <br />W <br />J�wg <br />YQI <br />