My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6744 Shelby Lynn Way
Zephyrhills
>
Building Department
>
Building Plans
>
6744 Shelby Lynn Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:06:02 AM
Creation date
2/19/2025 9:39:01 AM
Metadata
Fields
Template:
Building Plans
Street #
6744
Location
Shelby Lynn Way
Contractor
K Hovnanian Co LLC
Building Plans - Permit #
2513
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12 <br />SEE ROOF <br />PLAN <br />INSULATION PER - <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />ix PT DRAPE BLKG - <br />ABOVE WINDOWS 1/2" <br />G.W.B. <br />WINDOW PER PLAN <br />GYP.BD. _ <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @ 24" O.C. <br />BASE BOARD <br />TYP. 1-STORY WALL <br />SCALE: 1/2" = 1'-O" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />06 TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. WALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />PRECAST WIN. SILL <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />ob 0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />WINDOW <br />PROVIDE 2X4 <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />L-GYPSUM <br />BOARD Z <br />0- <br />3 1/2" cc <br />w <br />GARAGE a <br />k GYPSUM <br />BOARD <br />ELECTRIC METER----_________, <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD' <br />Xiv <br />ELECTRICAL cl) <br />STUCCO <br />PANEL <br />FINISH <br />N <br />i <br />EXTERIORS <br />5o <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GRADE <br />v <br />CONCRETE `\l <br />CURB REFER <br />TO PLANS <br />GYPSUM <br />BOARD <br />J" GYPSL <br />BOARD <br />NICHE F( <br />ELECTR11 <br />PANEL & <br />WIRING <br />ELECTRII <br />PANEL <br />EXTERIO <br />CMU BLC <br />WALL <br />CONCRE <br />CURB RE <br />TO PLAN; <br />DIONCRETI <br />SLAB ON <br />GRADE Al <br />GARAGE <br />FLOOR <br />12 <br />SEE ROOF <br />PLAN <br />1/2" (MIN.) J <br />CLG. BD. <br />(r TYPE 'X' GYP. BD. <br />TO BE PROVIDED <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />GARAGE SLAB, 4„ <br />SEE STRUCTURAL <br />PLANS <br />M <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OIL TOP OF C.M.U. <br />\qv(REFER TO-ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. w/ALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />DRIVEWAY PER COMMUNITY <br />SPECS <br />ob 0'-0" <br />SLOPE FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />WALL SECTION I@ GARAGE DOOR <br />SCALE: 1/2" = 1'-O" <br />OR SECOND <br />FLOOR LIVING SPACE <br />R EFER • <br />•2� <br />� <br />AMU <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = V-0" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />it <br />W <br />}2� <br />�00� } <br />Wui o ao <br />F- <br />Q?ww <br />_ CC J <br />- cr cr <br />Y O F- z <br />zzz=z <br />cr:5Q2J <br />wa=cca <br />�(n000 <br />= Z u- cn <br />� P < 9 � <br />� <br />Q <br />cz <br />Q o <br />O � <br />Q <br />Q <br />0 <br />0 <br />0 <br />z <br />O <br />0 <br />W- <br />Im <br />w <br />c <br />0 <br />0 .j <br />x <br />w <br />"OEM <br />cn <br />u <br />m< <br />~ <br />a <br />f-I <br />z <br />0 <br />IL <br />O <br />U3 <br />� <br />O <br />J <br />19 <br />N <br />O� <br />a<1 <br />No 77624 <br />STATE OF <br />OR10P • ������ <br />i� T1 S <br />COMMUNM <br />UNKS AT CALUSA <br />SPRINGS <br />FLAN # 6101 <br />RELEASED: 7/15/21 <br />SHEET <br />AlmS•22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.