Laserfiche WebLink
BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />' TYPICAL AT ALL WOOD <br />TO MASONRY <br />TRANSITIONS <br />2X <br />FRAMING <br />FLOOR <br />SHEATHING PER <br />SPEC. <br />RIM BOARD <br />REFER TO <br />-- <br />-STRUCT DWGS. <br />60 MIN. <br />GRADE D <br />PAPER <br />BACKED <br />t <br />LATH <br />WALL. <br />SHEATHING <br />7/8" 3-COAT <br />1 <br />STUCCO <br />_ SHEATHING <br />j t <br />FLUSH WITH <br />BLOCK WALL <br />j t <br />MID -WALL WEEP <br />1 <br />;REED/EXPANSION <br />JOINT <br />6" SELF ADHERED <br />FLASHING <br />t <br />CEMENTITIOU <br />% <br />COATING <br />BUILDING FELT <br />- ON TOP OF <br />CONC. BLOCK---�� <br />UNDER FLOOR <br />MAINTAIN 1/8" GAP <br />MEMBERS <br />BETWEEN SHEATHING <br />CONCRETE <br />AND TOP OF BLOCK <br />BLOCK <br />WALL <br />EXPANSION JOINT (EJ) AT FRAME & MASONRY <br />SCALE: 1/2" = 1'-0" <br />PREFORMED CONTROL <br />JOINT <br />FLANGE OF CONTROL <br />JOINTS TO BE WIRED TIED <br />TO LATH @ 9" O.C. MAX. (VERT.) <br />NOTE: DO NOT FASTEN CONTROL <br />JOINT TO WALL EVEN IF STUD <br />EXISTS BEYOND EXCEPT STAPLES W/ 8" <br />LEG MAY BE USED TO TEMP. <br />SECURE CONTROL JOINT <br />DURING INSTALLATION <br />FASTENERS TO BE SPACED @ 7" <br />O.C. MAX. VERTICALLY <br />LATH SHALL NOT BE BE CONTINUOUS <br />THROUGH CONTROL JOINTS <br />BUT SHALL BE STOPPED AND TIED AT <br />EACH SIDE PER ASTM C1063 7.10.1.4 <br />TYPICAL STUDS <br />TYPE "M" CONTROL JOINT (CJ <br />SCALE: N.T.S. <br />"L" FLASHING <br />SCALE: N.T.S. <br />$" THICK, 3 COAT <br />CEMENT PLASTER <br />60 MIN. GRADE D <br />PAPER BACKED LATH <br />APPROVED METAL LATH FASTENED @ 7" (VERT.) <br />O.C. MAX. AT SUPPORTS <br />BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />&T&lo1M9:11119:II►C] <br />PROVIDE 2X4 BLOCKING <br />FLAT MAX. 6" TO 8" FROM <br />CONTROL JOINT WHEN CONTROL <br />JOINT FALLS ON STRUCTURAL STUD <br />- , � �I�itl>•L� <br />NOTE: <br />1. FASTENERS FOR LATH TO BE NAILS OR <br />STAPLES IN COMPLIANCE W/ ASTM C1063 <br />2. WIRE TIES TO BE NO. 18 - 0.0475" WIRE <br />3. BLOCKING SHOWN MAY BE IN ADDITION TO <br />WALL STUDS REQUIRED PER PLAN <br />'VOOD SHEATHING <br />0 MIN. GRADE D PAPER BACKED <br />ATH OVER BARRICADE PLUS WRB <br />DR APPROVED EQUAL) <br />THICK, 3 COAT CEMENT PLASTER <br />1ETAL LATH <br />AP WRB & TAPE OVER ROOFMALL <br />',CREED <br />X5 "L" TYPE CONTINUOUS GALV. <br />1ETAL FLASHING (NAIL TO ROOF <br />►ECK, NOT WALL SHEATHING) <br />�E AND WATER SHIELD <br />5" VERTICAL AND 15" DOWN ROOF <br />-AP SHINGLE - DO NOT NAIL, <br />4STALL WITH ROOF CEMENT <br />IOOF CEMENT <br />oHNGLE ROOFING <br />BARRICADE PLUS WF <br />(OR APPROVED EQUA <br />LAP SIDING (PER BUILDE <br />MIN. LAP (PER MANUF. SPEC <br />STARTER STRIP (PER MANUF. SPEC <br />MIN. CLEARANCE (PER MANUF. SPEC <br />5X5 "L" TYPE CONTINUOUS GAL <br />METAL FLASHING (NAIL TO ROOF DEC <br />NOT WALL SHEATHIN <br />CAP SHINGLE - DO NOT NAIL, INSTAI <br />WITH ROOF CEMEl' <br />MEN <br />ROOF CEMEI' <br />SHINGLE ROOFI( <br />"L" FLASHING -SIDING <br />SCALE: N.T.S. <br />8" THICK, 3 COAT <br />CEMENT PLASTER <br />60 MIN. GRADE D PAPER BACKED LATH <br />BARRICADE PLUS WRB (OR APPROVED EQUAL) <br />WRAP LAYERS OF BUILDING <br />WRAP OVER NAILING FLANGE, STOP <br />WRB APPROX. 1-1/2" ABOVE SHINGLES <br />ROOFMALL SCREED <br />5X5 WALL FLASHING <br />KICK -OUT FLASHING (SEE DTL. BELOW) <br />FELT UNDERLAYMENT <br />OR ICE AND WATER SHIELD <br />AS REQ'D BY CODE <br />in <br />�— SHINGLE ROOFING <br />FASCIA WRAP <br />DRIP EDGE: OVERLAP 3", EXTEND <br />BELOW SHEATHING, MECH. FASTEN <br />4" O.C. MAX. <br />KICKOUT DETAIL <br />3� <br />BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />WOOD SHEATHING <br />WOOD CONSTRUCTION <br />60 MIN. GRADE D <br />PAPER BACKED LATH <br />METAL LATH <br />8" MID -WALL WEEP <br />SCREED <br />6" SELF-ADHESIVE <br />FLASHING <br />8" THICK, 3 COAT <br />CEMENT PLASTER <br />HORIZONTAL WEEP SCREED <br />SCALE: N.T.S. <br />STEP 1 STEP 2 <br />FOLC <br />FOLD INWARD @ PT. A <br />STEP 3 <br />FOLD INWARD @ PT. A <br />CREASE @ PT. B <br />CREASE @ PT. C <br />FOLD @ <br />`a'� 77° <br />0 <br />FOLD INWARD @ PT. A <br />CREASE @ PT. B <br />STEP 4 <br />0 <br />00 <br />WATERTIGHT SEAL. <br />FOLD. DO NOT CUT. <br />BOTTOM FLANGE <br />FOLD INWARD @ PT. A <br />CREASE @ PT. B <br />CREASE @ PT. C <br />FOLD PT. C OVER PT. B TILL <br />PT. C TOUCHES BOTTOM FLANGE <br />fY <br />W <br />= Iz <br />}Lu <br />�00} � <br />> <0 <br />UJ 0 H <br />W <br />0 <br />w cn W <br />Q = <br />J U) W W <br />� It It ft <br />LL00U) <br />Z Z.Z ~ Z <br />cc 15 < <br />W a 2 it a <br />� <br />Z LL <br />H Q Z 0 <br />F� <br />= c <br />n <br />Q O <br />O � <br />Q <br />a <br />cn <br />j <br />0=0 <br />o <br />lomm <br />o <br />w <br />0 <br />� <br />A <br />U <br />O <br />z <br />NONNI <br />p <br />� <br />0 <br />O <br />� <br />a <br />0 <br />a <br />W-j <br />a <br />w� <br />o <br />w <br />w <br />0 <br />U <br />cn <br />W <br />G <br />0� <br />�o <br />.0 <br />No 77824 �; # <br />STATE OF ; wIU <br />s/�F '•:°�ORtOP'�G�?� <br />SS�osvA%_ s` \\\ <br />commuNM <br />LINKS AT CALU A <br />SPRINGS <br />PLAN # 6102 <br />RELEASED: 7/13/21 <br />SHEET <br />GYP `i <br />