Laserfiche WebLink
FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />0OR <br />2-4/0 ALUMINUM 150 AMP 4: <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />tr /' 1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />III�III III III II <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL KEY <br />0 DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />-�- CEILING MOUNTED LED LIGHT FIXTURE <br />�- WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />Ov VAPOR PROOF LIGHT FIXTURE <br />+m LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />f) EXHAUST FAN <br />Q EXHAUST FAN/LIGHT COMBINATION <br />® CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />t4 TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />01 ELECTRIC METER <br />s ELECTRIC PANEL <br />_jmA_ DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I-- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2020 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O20 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2020 NEC 410.16(A) & (8) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />Ir <br />W <br />} 2 cr <br />Lu <br />z0E- <br />O} <br />Wccca c0 <br />oF- <br />wo <br />=03. <br />pwF- <br />Y O H Z <br />O <br />ui <br />Z Z Z <br />cc!5¢2-1 <br />Z_ <br />wCLmct <br />CD 0 00 <br />= Z LL (n <br />Zo <br />�F-Qcri <br />n <br />coc <br />n <br />Q o <br />O <br />H <br />�a <br />Q <br />O <br />O <br />O <br />U <br />O <br />ma <br />a <br />m <br />0 <br />a <br />(n <br />�- <br />O <br />J <br />U <br />I <br />VJ <br />w <br />w <br />m <br />wwo <br />U <br />o. <br />iL. <br />w <br />c <br />mi <br />l< <br />w <br />E-M <br />O <br />IL <br />A <br />O <br />E <br />U) <br />W <br />O <br />0 <br />4 <br />20 <br />�Z <br />aaaaa <br />COMMUNITY: <br />LINKS ALU A <br />SPRINGS <br />PLAN # 6101 <br />RELEASED: 02/04/21 <br />SHEET <br />E• <br />