Search
6809 Shelby Lynn Way
Zephyrhills
>
Building Department
>
Building Plans
>
6809 Shelby Lynn Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 12:05:33 PM
Creation date
2/19/2025 9:41:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6809
Location
Shelby Lynn Way
Contractor
K Hovnanian Co LLC
Building Plans - Permit #
1514
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERMANENT ROOF TR65 BRACING NOTES: <br />(51N6LE FAMILY HOME OR TOWNHOUSE GON5TRUGTION, WITH ROOF TRUSSES SPACED NO MORE THAN 24" O.G) <br />I. HOOD TRUSSES SHALL BE BRACED AND ERECTED IN ACCORDANCE WITH THE BUILDING COMPONENT SAFETY <br />INFORMATION %51) "GUIDE TO GOOD PRACTICE FOR HANDLING, IN5TALLING, RE5TRAININ6 4 BRACING OF <br />METAL PLATE CONNECTED WOOD TRU55E5," (2008 EDITION). <br />2. TOP CHORD BRACING: <br />TOP CHORDS SHALL BE BRACED BY DIRECT -APPLIED PLYWOOD/05B 5HEATHIN6. <br />• IF 5HEATHIN6 15 NOT DIRECTLY APPLIED TO EITHER TOP CHORD OF TRUSS OR TO PURLIN5 FASTENED TOP <br />CHORD, CONTACT M4K FOR BRAGIN6 DE516N. <br />3. BOTTOM CHORD BRACING: <br />a. THE BOTTOM CHORDS SHALL BE BRACED BY DIRECT -APPLIED G.W.B. CEILING <br />4. WEB MEMBER BRACING: <br />THE TRU55 MANUFACTURER SHALL INDICATE THE TRUSS MEMBER5 (WEBS, VERTICALS) THAT REQUIRE <br />LATERAL 13RAGING/RE5TRAINT. <br />a. T OR 'L' BRACE: <br />WHERE BRAGING 15 REQUIRED A5 INDICATED ON SHOP DRAWING, UTILIZE 'T' OR 'L' BRACES (REFERENCE <br />BG51-133 F16URE5 B3-18 4 133-IQ). SHOP APPLIED REINFORCEMENT PER BGSI-B3 F16URE5 133-22 4 BG-23 15 <br />ACCEPTABLE. <br />• 'T' 4 'L' REINFORGING MATERIAL SHALL MATCH THE 51ZE OF THE WEB/VERTIGAL MEMBER. <br />• 'L' 4 'T' REINFORGIN6 TO BE A MINIMUM OF 40% OF THE LENGTH OF THE HEB/VERTIGAL MEMBER. <br />• FA5TEN 'L' OR 'T' REINFORCING TO Pf B/VERTIGAL W/ Ibd 6UN NAILS (0.1310 1/2") AT 6" O.G. <br />b. CONTINUOUS LATERAL BRAGIN6 ALTERNATE: <br />WHEN THREE (3) OR MORE 51MILARLY GONFI6URED ROOF TRUSSES AL16N, CONTINUOUS ROWS OF LATERAL <br />BRAGIN6 MAY BE USED IN LIEU OF THE ABOVE -NOTED 'L' OR 'T' BRAGE5. <br />• CONTINUOUS ROWS OF LATERAL BRACING SHALL CONSIST OF MINIMUM 2x4. ROWS SHALL BE LAP SPLICED <br />ONE TRU55 13EYOND IN EACH DIRECTION. SECURE BRACE TO EACH TRU55 COMPRESSION WEB W (2) Ibd <br />GUN NAILS (0.1310 1/2"). <br />• CONTINUOUS LATERAL BRAGIN6 SHALL BE RE5TRAINED BY DIA60NAL BRAGIN6 (MIN. 2" THICK NOMINAL <br />LUMBER 4 MINIMUM 5PF 'STUD' GRADE MATERIAL). TH15 BRACING 15 TO 13E CONTINUOUS. PROVIDE ONE <br />ROW OF DIAGONAL BRACING AT VERTICAL WEB MEMBERS OF TF465B CLOSEST TO EACH 6ABLE END <br />WALL 4 ADDITIONAL DIA67ONAL5 AT 20'-0" A5 REQUIRED. <br />DIAGONAL BRACE NAILED TO OPP051TE <br />PROVIDE (2) Ibd NAILS o 51DE OF WEB AT 20'-0" MAX. (TO PREVENT <br />EACH MEMBER LATERAL MOVEMENT) DIRECT -APPLIED PLYWOOD/0513 <br />ROOF 5HEATHIN67 <br />COMPRESSION HEB (SLOPING <br />OR VERTICAL) <br />seal: r - <br />XTE : F <br />© copyright <br />structural Engineering, Inc. <br />n z <br />Z_ <br />w <br />w N <br />Z <br />ED �— <br />Z <br />wQ N0- <br />J a) <br />CC Ir <br />Z=� <br />v Q <br />�Er� <br />cb <br />TJ ME <br />�~ Qg <br />Z <br />W <br />� O <br />y m` _ <br />W C N <br />M&K project number: <br />CONTINUOUS LATERAL BRACE <br />ALTERNATE o (3) OR MORE <br />ed m r <br />drawn by: <br />ADJACENT SIMILAR TRUSSES (SFFro <br />................. .... NODIRVLTRU55 SHOP DRAWINGS <br />2x 5TRONG6ACK MAY BE <br />INSTALLED FOR GON5TRUCTABILITY <br />issue date: <br />TO KEEP EVEN 5PAGIN6 AT <br />BOTTOM CHORD (NOT REQ'D FOR <br />srRUCT U� <br />REVISIONS: <br />date: <br />GONTIN. LATERAL BRACING <br />TO LAP ACROSS MIN. (1) DIREGT-APPLIED <br />TRU55 BAY A5 5HOWN 616113 CEILING <br />SECTION B-B <br />KTOar re WnW MOM W OR HM SHux MWM AM Ma M <br />WEB MEMBER REQUIRIN6 <br />B BRAGIN6 A5 INDICATED BY <br />►—� I/F TRU55 MANUFACTURER <br />2x 5TRON65AGK <br />(NOT REQ V FOR <br />STRUCTURE) <br />DIREGT-APPLIED <br />PLYWD/05B <br />DIREGT-APPLIED <br />616113 GEILIN6 — <br />2x 5TRONG5ACK5 MAY BE <br />INSTALLED FOR GON5TRUCTABILITY <br />TO KEEP EVEN 5PAGIN6 AT <br />BOTTOM CHORD NOT REQ'D FOR <br />5TRUGTURE) <br />El 'L' OR 'T' BRACING o <br />HEBS DE5IGNATED BY <br />TRU55 MANUF. <br />PERMANENT TRUSS <br />BRAG I N6 DETAILS $ NOTES <br />SLAW: NM <br />DIWT APPLIIV GCILIN6 <br />068-2001 1 <br />JSB <br />MJT <br />01-2 6-21 <br />�a <br />C <br />J <br />W <br />0 <br />2 <br />0 <br />z <br />0 <br />n. <br />initial: <br />0 <br />J <br />Q <br />0 <br />J <br />LL <br />U <br />0 <br />Z <br />x <br />(L <br />W <br />d <br />U) <br />J <br />d <br />U <br />d <br />U) <br />z <br />J <br />LETTERED DETAIL5 ARE TYPIGAL FOR NUMBERED DETAIL5 ARE PLAN <br />TH 15 HOME � 5HALL BE IMPLEMENTED IN 5PEG I F I G AND ARE ONLY REGU I RED <br />ALL APPL I GABLE AREAS. THESE WHERE 5PEG I F I GALLY I ND I GATED <br />DETAILS ARE NOT "GUT" ON THE PLANS. ("GUT") ON THE PLANS. <br />sheet: <br />PBSBpo 1 <br />