Laserfiche WebLink
ROOF SHINGLES OVER <br />12 <br />15# ROOFING FELT <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />PLM <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />nnono(-) <br />STRUCTURAL. <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION PER <br />COMMUNITY SPEC. <br />SEE <br />SEE ENERGY CALCS. <br />_ _ <br />ELEV. <br />1/2" (MIN.) CLG. BD. <br />2x6 ALUM WRAPPED FASCIA <br />ix PT DRAPE BLKG <br />BD. w/ALUM DRIP EDGE. <br />ABOVE WINDOWS 1/2" <br />SOFFIT PER SPECS <br />G.W.B. <br />SEE STRUCTURAL <br />WINDOW PER PLAN <br />r <br />PLAN <br />GYP.BD. — <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT PRECAST WIN. SILL <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. I / <br />FURRING @ 24" O.C. j - _3SLOPE GRADE AWAY <br />BASE BOARD —� FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL C@ WINDOW <br />SCALE: 1 /2" = 1'-O" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />k GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCC <br />FINISH <br />EXTERIOR- <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GYPSUM - <br />GYPSUM <br />BOARD <br />BOARD Z <br />g <br />�31/2" a. <br />j" GYPSUh <br />w <br />GARAGE a <br />BOARD <br />NICHE FOI <br />ELECTRIC <br />PANEL & <br />WIRING <br />N <br />ELECTRICAL <br />PANEL ELECTRIC <br />PANEL <br />N <br />co `O EXTERIOR <br />CMU BLOC <br />WALL <br />`v <br />CONCRETE a CONCRETI <br />CURB REFER CURB REF <br />TO PLANS TO PLANS <br />CONCRETE <br />A e SLAB ON <br />GRADE - GRADE AT <br />GARAGE <br />FLOOR <br />ROOF SHINGLES OVER <br />12 15# ROOFING FELT <br />SEE ROOF PRE-ENGINEERED ROOF <br />PLAN TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OIL TOP OF C.M.U. <br />(REFER TO ELEV.) <br />SEE L 'I-2x6 ALUM WRAPPED FASCIA <br />ELEV. BD. w/ALUM DRIP EDGE. <br />1/2" (MIN.) <br />------ <br />SOFFIT PER SPECS <br />CLG. BD. <br />(�' TYPE'X' GYP. BD. <br />SEE STRUCTURAL <br />TO BE PROVIDED <br />PLAN <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLAB, 4„ DRIVEWAY PER COMMUNITY <br />SEE STRUCTURALSPECS <br />,.. <br />PLANS SLOPE J SLOPE FIN. FL. <br />`v I - —FOUNDATION <br />cl) PER STRUCTURAL DRAWINGS <br />WALL SECTION � GARAGE DOOR <br />SCALE: 1/2" = 1'-0" <br />ATTIC OR SECOND <br />FLOOR LIVING SPACE <br />REFER • PLANS• <br />�ll�il <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />�Ee 03ZO <br />?1 <br />W <br />Wz0= <br />O >- H <br />>oWC¢0 <br />W <br />cr- <br />=pwg <br />n�cr� <br />Ye -z <br />zQzQz� III <br />�JQ� -j <br />wa2iYn- <br />=ZLLW <br />Q o <br />O �Q <br />Q <br />0 <br />0 <br />U <br />O <br />m <br />� <br />oz <br />O <br />.j <br />u U <br />Ono <br />Un <br />Noma <br />z <br />O <br />IL <br />0 <br />w <br />G <br />U) <br />04 <br />r <br />�Z <br />C <br />aaaaa <br />COMMUNITY: <br />UNKS AT CAUSA <br />SPRINGS <br />PLAN # 61 Of <br />RELEASED: 02/04/21 <br />SHEET <br />A5•22 <br />