Laserfiche WebLink
'CONNECT <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1/4"=1'-0" <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />O OR COPPER <br />OR <br />2 4/0 ALUMINUM 200 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. I BREAKER <br />1 /2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL KEY <br />0 DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />Fl GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />+ FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />VAPOR PROOF LIGHT FIXTURE <br />Pc LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />4 EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />© CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />So SMOKE DETECTOR <br />E4 TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />p ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I-- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2014 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14 <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN <br />TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL <br />COMPLIANCE WITH N.F.P.A. 70A, FLORIDA RESIDENTIAL CODE <br />2017, NFPA 2014 AND ALL APPLICABLE LOCAL STANDARDS, <br />CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2014 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS <br />AND <br />DISCONNECTS IN COMPLIANCE WITH NEC 110.26. <br />14. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER <br />NEC 406.12. <br />15. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE PER. <br />FBC E3901.9. <br />x <br />W <br />} _ CC <br />� O O I— <br />Lu <br />�Q <br />>O <br />LuZ)ol- <br />cnUWW <br />� <br />OL � J <br />�m�Ir <br />ZOOW <br />wJ¢2-1 <br />a:ir <br />I <br />_3cnoOU <br />Z=zLLcn <br />�F-QZ❑ <br />ri <br />N <br />n <br />Q o <br />O <br />� <br />a <br />Q <br />O <br />u <br />® <br />z <br />a)0 <br />® <br />j <br />L� <br />i� <br />® <br />i.Lr <br />U <br />= <br />r <br />� <br />w <br />w <br />t <br />w <br />"mm" <br />[L <br />i"� <br />u <br />U <br />w <br />m< <br />mi <br />w <br />w <br />w <br />w <br />x <br />X <br />U) <br />O_ <br />r <br />ce. <br />W <br />z <br />Z <br />08 <br />a:Z <br />a<Qaa <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 10/6/20 <br />SHEET <br />EIA <br />