Laserfiche WebLink
12 <br />SEE ROOF <br />PLAN <br />INSULATION PER — <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />1x PT DRAPE BLKG - <br />ABOVE WINDOWS 1/2" <br />G.W.B. <br />WINDOW PER PLAN <br />GYP.BD. <br />WINDOW SILL <br />112" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO 1x2 PT. <br />FURRING @a 24" O.C. <br />BASE BOARD <br />SEE SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN REFER TO PLANS <br />FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />== w: W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />m BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />jI u \, \-P(REFER TO ELEV) <br />INSULATION AS I _ 2X ALUM WRAPPED FASCIA <br />PER SPECS. BD. WALUM DRIP EDGE <br />PRE-ENGINEERED SOFFIT AS PER SPECS. <br />GABLE END ROOF <br />TRUSS - REFER TO HURRICANE STRAP EACH END OF <br />STRUCTURALS TRUSS - REFER TO STRUCTURAL <br />1/2" (MIN.) CLG. BD. MASONRY LINTEL, SEE <br />STRUCTURALS <br />TYP. HIPPED PENT ROOF DETAIL <br />SCALE: 1/2" = V-0" 1-STORY- MASONRY WALL <br />SEE <br />ELEV. <br />ROOF SHINGLES OVER <br />15# ROOFING FELT <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />At TOP OF C.M.U. <br />(REFER TO ELEV) <br />2x6 ALUM WRAPPED FASCIA <br />BD. W/ALUM DRIP EDGE. <br />SOFFIT PER SPECS <br />SEE STRUCTURAL <br />PLAN <br />PRECAST WIN. SILL <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL 0 WINDOW <br />SCALE: 1/2" = V-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4 <br />FRAMED <br />GYPSUM <br />BOARD z <br />g <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />3 1/2" <br />w <br />I GARAGE °- <br />2" GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE i <br />PLANS. VERIFY _ <br />INSTALLATION IN N <br />FIELD ' ELECTRICAL M <br />STUCCO PANEL <br />FINISH <br />cV <br />EXTERIOR 00 <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />CONCRETE <br />CURB REFER <br />TO PLANS <br />H1 <br />? % �`�� <br />_A., "4 <br />GRADE <br />GYPSUM <br />BOARD <br />2" GYPSUM — <br />BOARD <br />NICHE FOR - <br />ELECTRICAL <br />PANEL & <br />WIRING <br />ELECTRICAL - <br />PANEL <br />EXTERIOR <br />CMU BLOCK <br />WALL <br />cv CONCRETE — <br />CURB REFER <br />TO PLANS <br />- CONCRETE-- <br />SLAB ON <br />GRADE AT <br />GARAGE <br />FLOOR <br />OCT 12 2020 <br />•' * NO 77824 <br />S <br />®� ATE OF <br />ROOF SHINGLES OVER <br />12 15# ROOFING FELT <br />SEE ROOF PRE-ENGINEERED ROOF <br />PLAN TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />TOP OF C.M.U. <br />it (REFER TO ELEV) <br />=7 4SEE \-2x6 ALUM WRAPPED FASCIA <br />ELEV. BD. W/ALUM DRIP EDGE. <br />1/2" (MIN.) ------ SOFFIT PER SPECS <br />CLG. BD. <br />(a" TYPE'X' GYP. BD. SEE STRUCTURAL <br />TO BE PROVIDED PLAN <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLALL <br />DRIVEWAY PER COMMUNITY <br />SEE STRUCT4" SPECS <br />PLANS OIL 01 <br />SLOPE FIN. FL. <br />Ems - <br />co <br />WALL SECTION <br />SCALE: 1/2" = V-0" <br />ATTIC <br />FLOOR <br />REFER <br />OR SECOND <br />LIVING SPACE <br />TO PLANS <br />T.O. M <br />z <br />J <br />d <br />� <br />w <br />d <br />� I <br />I I <br />I <br />I I <br />� I <br />I <br />I I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />N <br />co <br />00 <br />cv <br />' <br />- <br />N <br />FA <br />-1 <br />L <br />1' <br />V-6" <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = V-0" <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />GARAGE DOOR <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />T_ <br />w <br />Ir <br />W z O = <br />O H <br />> ct 0 <br />U) zw <br />WQ ❑ ~ <br />2 J <br />Z)crcrIt <br />Y01-z <br />LL O O <br />Z Z Z H Lu <br />J Q J <br />uj FL cr . <br />j U) 0 0 <br />�2ZLL(A <br />H Q Z 0 <br />00 <br />n <br />Q <br />O � <br />Q <br />H <br />0 <br />0 <br />0 <br />4 <br />r� <br />V <br />0 <br />i <br />I� <br />z <br />INEENE! <br />0 <br />® <br />M� <br />w <br />U U <br />w <br />MONO w <br />MENEM <br />cn <br />rrIL <br />vl <br />m< <br />w <br />w <br />w <br />x <br />ffX <br />vl <br />m< I <br />0 <br />r <br />cr <br />ch <br />W <br />0 <br />Z <br />0 <br />uj <br />Q <br />r <br />0 <br />WII <br />Z <br />aaaaa <br />COMMUNITY; <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 10/6/20 <br />SHEET <br />A5.2 <br />