My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6872 Shelby Lynn Way
Zephyrhills
>
Building Department
>
Building Plans
>
6872 Shelby Lynn Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:07:19 PM
Creation date
2/19/2025 9:43:40 AM
Metadata
Fields
Template:
Building Plans
Street #
6872
Location
Shelby Lynn Way
Contractor
K Hovnanian Co LLC
Building Plans - Permit #
1081
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADD BLOCKING <br />m <br />n------� C'3 <br />LAUNDRY ' <br />I�N I <br />EL ol <br />I N <br />I, <br />DISCONNECT' <br />I <br />BR3 <br />j WIC <br />0 <br />ADD BLOCKING <br />� BEDROOM 3 <br />---------------- <br />,SD <br />HALL <br />BATH <br />I ° <br />_ OS <br />3-BULB WIC <br />I <br />� I I <br />d�YiF <br />T-F►X:-----T-- <br />L <br />HALL <br />ADD BLOCKING <br />BEDROOM 4 <br />SECOND FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />mmmm_� <br />4a I -I <br />; <br />LOFT <br />ADD BLOCKING <br />�I <br />20 AMP DED <br />OUTLET FOF <br />HOOD/ OPT. WA <br />HOOC <br />RANGE <br />FIEL <br />VERIF <br />METE <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />OR COPPER <br />0 OR <br />2-4/0 ALUMINUM 200 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />PVC 1 /2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL KEY <br />0 DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />oy VAPOR PROOF LIGHT FIXTURE <br />+m LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />C) EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />F4 TELEPHONE (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />D1 ELECTRIC METER <br />s ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Q JUNCTION BOX <br />STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2014 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4.OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />S. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN <br />TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL <br />COMPLIANCE WITH N.F.P.A. 70A, FLORIDA RESIDENTIAL CODE <br />2017, NFPA 2014 AND ALL APPLICABLE LOCAL STANDARDS, <br />CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2014 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS <br />AND <br />DISCONNECTS IN COMPLIANCE WITH NEC 110,26. <br />14. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER <br />NEC 406.12. <br />15. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE PER <br />FBC E3901.9. <br />p <br />W <br />r II= <br />LUz0m O� <br />� <br />wLu ccQO <br />p <br />Vww cA <br />QpLu <br />JU)Lu— <br />jr cr. I= <br />ojfZZOW <br />J <br />: a ZI <br />LJJ�_IrCL <br />�cn❑00 <br />❑ = Z Il (A <br />�1-Qzp <br />cz rIT <br />n <br />Q o <br />H <br />O �a <br />Q <br />0 <br />z <br />u <br />O <br />a <br />Z <br />m <br />o <br />c� <br />U <br />u <br />r■.n <br />c a <br />O <br />A <br />Z U <br />w<w <br />w <br />O <br />UJ <br />o <br />O <br />j <br />z <br />LLO <br />191 <br />O <br />OG <br />cn <br />W <br />0 <br />N <br />O� <br />�o <br />itz <br />aaaaa <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6103 <br />RELEASED: 10/9/20 <br />SHEET <br />El,l <br />
The URL can be used to link to this page
Your browser does not support the video tag.