My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6888 Shelby Lynn Way (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6888 Shelby Lynn Way (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 2:41:01 PM
Creation date
2/19/2025 9:44:28 AM
Metadata
Fields
Template:
Building Plans
Street #
6888
Location
Shelby Lynn Way
Contractor
K Hovnanian Co LLC
Description
Revision
Building Plans - Permit #
446
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3-BULB <br />HALL <br />BATH <br />3-BULB <br />d-%%AfNAr- i r- <br />r GFII' <br />L--J' <br />220V <br />i GFI <br />LAUNDRY L______I <br />ADD BLOCKING <br />LOFT <br />CL <br />ADD BLOCKING <br />BEDROOM 2 <br />OS WIC <br />ADD BLOCKING <br />OWNER'S SUITE <br />I t Sp <br />I I <br />LIGHT FIX. DATA <br />hn <br />I <br />I <br />I <br />I <br />i <br />.-..► <br />L <br />CL r <br />SECOND FLOOR ELECTRICAL PLAN <br />SCALE: 1/4"=1'-0" <br />ADD BLOCKING <br />BEDROOM 4 <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />1 -1 /0 COPPER <br />0 OR <br />2-4/0 ALUMINUM <br />200 AMP 42 <br />METER 1-3/0 ALUMINUM <br />CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. <br />BREAKER <br />PVC 1 /2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />I <br />III III III III III <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />A/C <br />DISCONNECT <br />20 AMP DED. <br />OUTLET FOR <br />HOOD/ OPT. MW <br />HOOD <br />RANGE <br />WH <br />DISCONNECT <br />ELECTRICAL KEY <br />b� DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />Fl GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />I- WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />01 VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />fj EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® CHIMES (OPTIONAL) <br />ID PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />Q SMOKE DETECTOR <br />f4 TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />41 ELECTRIC METER <br />= ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I,— STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2014 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4.OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN <br />TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL <br />COMPLIANCE WITH N.F.P.A. 70A, FLORIDA RESIDENTIAL CODE <br />2017, NFPA 2014 AND ALL APPLICABLE LOCAL STANDARDS, <br />CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2014 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS <br />AND <br />DISCONNECTS IN COMPLIANCE WITH NEC 110.26. <br />14. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER <br />NEC 406.12. <br />15. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE PER <br />FBC E3901.9. <br />W <br />} 2 � <br />�00� <br />} <br />>oWC¢0 <br />W 0 H <br />W <br />Q Q w <br />QpWF- <br />_ <br />J <br />> <br />IL U) LLj LU <br />cc CC = <br />Y 0 H Z <br />06LI_00cn <br />ZZZP:z <br />CC J Q M J <br />W CL==D.. <br />�cn000 <br />=ZLL.CI) <br />H Q z <br />Q O ., <br />0 <br />Z <br />la— <br />0 <br />O <br />uA <br />o <br />za <br />1°01 <br />O � <br />u? <br />� <br />U <br />oWU <br />Opp <br />z u <br />w <br />w <br />I� <br />E <br />w <br />U) <br />A <br />0 <br />0 <br />w <br />O <br />W <br />G <br />oa <br />rno 16z <br />QQQQQ <br />COMMUNITY: <br />SPRINGS <br />PLAN # 6102 <br />RELEASED: 6/10/20 <br />SHEET <br />E1*1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.