My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6909 Shelby Lynn Way
Zephyrhills
>
Building Department
>
Building Plans
>
6909 Shelby Lynn Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 11:39:04 AM
Creation date
2/19/2025 9:45:39 AM
Metadata
Fields
Template:
Building Plans
Street #
6909
Location
Shelby Lynn Way
Contractor
K Hovnanian Co LLC
Building Plans - Permit #
437
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IT <br />PERMANENT ROOF TRU55 BRACING NOTES: <br />(SINGLE FAMILY HOME OR TOWNHOUSE CONSTRUCTION, WITH ROOF TRUSSES SPACED NO MORE THAN 24" O.C) <br />I. WOOD TRU55E5 SHALL BE BRACED AND ERECTED IN ACCORDANCE WITH THE BUILDING COMPONENT SAFETY <br />INFORMATION (BC51) "GUIDE TO 6000 PRACTICE FOR HANDLING, IN5TALLIN6, RESTRAINING t 13RAGIN6 OF <br />METAL PLATE CONNECTED WOOD TRU55E5," (2008 EDITION). <br />2. TOP CHORD BRACIN6: <br />TOP CHOR05 SHALL BE BRACED BY DIRECT -APPLIED PLYWOOD/OSB SHEATHING. <br />• IF SHEATHING 15 NOT DIRECTLY APPLIED TO EITHER TOP CHORD OF TRU55 OR TO PURLIN5 FASTENED TOP <br />CHORD, CONTACT MW FOR BRACIN6 DE516N. <br />3. BOTTOM CHORD BRACIN6: <br />a. THE BOTTOM CHORDS SHALL BE BRACED BY DIRECT -APPLIED 6.161B. GEILIN6 <br />4. WEB MEMBER BRACIN6: <br />THE TRU55 MANUFACTURER SHALL INDICATE THE TRU55 MEMBERS (WEB5, VERTICALS) THAT REQUIRE <br />LATERAL BRAGIN6/RE5TRAINT. <br />a. 'T' OR 'L' BRACE: <br />WHERE BRACING 15 REQUIRED AS INDICATED ON SHOP DRAWING, UTILIZE 'T' OR 'L' BRAGE5 (REFERENCE <br />BC51-133 FIGURES 133-18 t 133-4. SHOP APPLIED REINFORCEMENT PER 13651-133 FIGURES 133-22 t BC-23 15 <br />ACCEPTABLE. <br />• 'T' t 'L' REINFORGIN6 MATERIAL SHALL MATCH THE 51ZE OF THE NEB/VERTICAL MEMBER. <br />• 'L' t 'T' REINFORGIN6 TO BE A MINIMUM OF 40% OF THE LENGTH OF THE NEBNERTICAL MEMBER. <br />• FASTEN 'L' OR "f' REINFORGIN6 TO WEBNERTICAL W/ Ibd GUN NAILS (0.131x3 I/2") AT b' O.G. <br />b. CONTINUOUS LATERAL BRACING ALTERNATE: <br />WHEN THREE (3) OR MORE 51MILARLY GONFIOURED ROOF TRU55E5 ALIGN, CONTINUOUS ROW5 OF LATERAL <br />BRACIN6 MAY BE USED IN LIEU OF THE ABOVE -NOTED 'L' OR 'T' BRACES. <br />• CONTINUOUS ROW5 OF LATERAL BRACIN6 SHALL CONSIST of MINIMUM 2x4. ROWS SHALL BE LAP 5PLIGED <br />ONE TRU55 BEYOND IN EACH DIRECTION. 5ECURE BRACE TO EACH TRV55 COMPRESSION WEB w/ (2) Ibd <br />6UN NAILS (0.1310 1/2"). <br />• CONTINUOUS LATERAL BRACIN6 SHALL BE RESTRAINED BY DIAGONAL BRAGIN6 (MIN. 2' THICK NOMINAL <br />LUMBER t MINIMUM SIFF 'STUD' GRADE MATERIAL). THIS BRACIN6 15 TO BE CONTINUOUS. PROVIDE ONE <br />ROW OF DIAC70NAL BRACIN6 AT VERTICAL WEB MEMBERS OF TRUSSES CLOSEST To EACH GABLE END <br />WALL t ADDITIONAL DIA60NAL5 AT 20'-0' AS REQUIRED. <br />DIAGONAL BRACE NAILED TO OPP051TE <br />PROVIDE (2) Ibd NAILS o SIDE OF WEB AT 20'-0" MAX. (TO PREVENT <br />EACH MEMBER LATERAL MOVEMENT) DIRECT -APPLIED PLYWOOD/0513 <br />A ROOF SHEATHING <br />COMPRESSION WEB (5LOPING <br />OR VERTICAL) <br />seal; <br />�a�saaeae®�a® <br />�t- <br />© copyright` 101N, <br />• . • �. <br />sdb�,.%0� <br />1 M <br />Z <br />J� <br />W <br />W <br />Z <br />z <br />Z <br />W <br />J <br />Q <br />Z <br />U <br />WEF- <br />T� <br />i —1 <br />JH <br />z <br />W <br />G <br />y <br />W <br />M&K project number; <br />N <br />0 <br />rn <br />a <br />Q v <br />A 4 <br />et <br />CM <br />E <br />m � <br />Q <br />;v <br />o cc <br />M Uh <br />0 <br />CD <br />N <br />M d <br />CONTINUOUS LATERAL BRACE <br />O 6 8" 2, O O 1 1 <br />ALTERNATE o (3) OR MORE <br />ro'ect m r; <br />p J 9 <br />drawn by; <br />KG K <br />......... ADJACENT 51MILAR TRU55E5 (5EE <br />.:::::.................. : _ ;;:; ;;;:;:;;:..:;;:;:;::.::;::;.:.::.:;:;;;;;:;:::;:;:;::::::;:;;::::;;:; <br />\.................... INDIV. TRUSS SHOP DRAAIN65 <br />FOR LOCATIONS) <br />2x STRON6713ACK MAY BE INSTALLED FOR GONSTRUGTABILITY <br />Issue date; <br />O4" `-1N"2O <br />TO KEEP EVEN 5PAGIN6 AT <br />BOTTOM GHORD NOT REQV FOR <br />STRUCTURE) <br />date; <br />initial; <br />CONTIN. LATERAL BRAGIN6 <br />TO LAP ACROSS MIN. (I) DIREGT-APPLIED <br />TRU55 BAY A5 5HOWN 616113 GEILIN6 <br />SECTION B-B <br />ALTERNATE hETWV H ME (a) OR NORM SIMLAR T t**S ARM 6ROM <br />WEB MEMBER REQUIRIN6 <br />B BRACIN6 AS INDICATED BY <br />TRUSS MANUFACTURER <br />D ' E(22x 5TRON6$ACK5 MAY BE <br />� <br />2x S INSTALLED FOR CON5TRUCTABILITY 4: <br />NOT REQFOORR To KEEP EVEN 5PAGIN(9 AT �~ <br />STRUCTURE) BOTTOM CHORD (NOT REQ'D FOR <br />5TRZTURE) <br />DIRECT -APPLIED <br />PLYWD/05B <br />rCz <br />Z <br />B <br />DIRECT -APPLIED 'L' OR 'T' BRACIN6 0 <br />6Y8 GEILIN6 WE55 DE516NATED BY <br />TRUSS MANUF. <br />TYPICAL TPV55 ELEVATION <br />PERMANENT TRUSS <br />( A 3BRACIN6 DETAILS $ NOTES <br />WALII: NONE DIREGT APPLIW GEILIN6 <br />V 1T <br />LETTERED DETAILS ARE TYPICAL FOR NUMBERED DETAILS ARE PLAN <br />TH 15 HOME $ SHALL BE IMPLEMENTED IN 5PEG I E I G AND ARE ONLY REQU I RED <br />ALL APPLICABLE AREAS. THESE WHERE SPECIFICALLY INDICATED <br />DETAILS ARE NOT "GUT" ON THE PLANS. ("GUT") ON THE PLANS. <br />d <br />H <br />W <br />sheet: <br />J <br />W <br />0 <br />:2 <br />0 <br />2 <br />z <br />d <br />Q <br />O <br />LL <br />PBS��I <br />
The URL can be used to link to this page
Your browser does not support the video tag.