Laserfiche WebLink
2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />0 OR <br />2-4/0 ALUMINUM 150 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />C#4PER OR ALUM. BREAKER <br />C <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />ELECTRICAL KEY <br />I DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />R GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />9 THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />-�- CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />01 VAPOR PROOF LIGHT FIXTURE <br />+c LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />fj EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />9 CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />Fl TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />ELECTRIC METER <br />s ELECTRIC PANEL <br />—•�- DISCONNECT SWITCH <br />Q JUNCTION BOX <br />STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT—INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2014 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4.OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN <br />TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL <br />COMPLIANCE WITH N.F.P.A. 70A, FLORIDA RESIDENTIAL CODE <br />2017, NFPA 2014 AND ALL APPLICABLE LOCAL STANDARDS, <br />CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2014 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH —EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS <br />AND <br />DISCONNECTS IN COMPLIANCE WITH NEC 110.26. <br />14. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER <br />NEC 406.12. <br />15. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE PER <br />FBC E3901.9. <br />JUL 21 2020 <br />Ir <br />W <br />WZO= <br />O >- H <br />>c <br /><0 <br />III Z)C)F— <br />Q�LuW F— <br />J U) W <br />m <br />Y Q H Z <br />�Ii00U) <br />Z Z Z< co ~ Z <br />i Q J <br />W a- <br />m _ <br />cn000 <br />Z)=ZILL U) <br />�I—QZr� <br />Rl <br />r\ <br />a <br />0 <br />0 <br />0 <br />r� <br />V <br />O <br />00 <br />a <br />00 <br />O <br />0 j <br />J <br />w <br />i <br />0 <br />�.., <br />= <br />lA <br />w <br />u <br />a <br />w <br />U) <br />W I <br />zI <br />0 <br />a <br />I <br />A <br />Z <br />O_ <br />i <br />I <br />i <br />c <br />0 <br />c <br />c <br />cn <br />O� <br />c <br />c <br />. <br />o <br />Z <br />f <br />11A <br />i <br />c <br />c <br />c <br />F <br />c <br />i <br />c <br />c <br />COMMUNITY: <br />LINKS SPRING <br />c <br />PLAN # 6101 <br />RELEASED: 5/15/20 <br />SHEET <br />E • <br />