Search
6939 Shelby Lynn Way
Zephyrhills
>
Building Department
>
Building Plans
>
6939 Shelby Lynn Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 12:42:09 PM
Creation date
2/19/2025 9:47:10 AM
Metadata
Fields
Template:
Building Plans
Street #
6939
Location
Shelby Lynn Way
Contractor
K Hovnanian Co LLC
Building Plans - Permit #
438
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERMANENT ROOF TRU55 BRACING NOTES: <br />(51N67LE FAMILY HOME OR TOWNHOU5E GON5TRUGTION, WITH ROOF TRU55E5 5PAGED NO MORE THAN 24" O.G) <br />I. WOOD TRU55E5 SHALL BE BRACED AND ERECTED IN ACCORDANCE WITH THE BUILDING COMPONENT 5AFETY <br />INFORMATION (6651) "GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING, RESTRAINING 4 BRACING OF <br />METAL PLATE CONNECTED WOOD TRU55E5," (2008 EDITION). <br />2. TOP CHORD BRACING: <br />TOP CHORDS SHALL BE BRACED BY DIRECT -APPLIED PLYW000/055 5HEATHIN65. <br />• IF 5HEATHING 15 NOT DIRECTLY APPLIED TO EITHER TOP CHORD OF TRU55 OR TO PURLIN5 FA5TENED TOP <br />CHORD, CONTACT MW FOR BRACING DE516N. <br />3. BOTTOM CHORD BRAGING: <br />a. THE BOTTOM CHORD5 SHALL BE BRACED BY DIREGT-APPLIED G.W.B. GEILING <br />4. WEB MEMBER BRACING: <br />THE TRU55 MANUFACTURER SHALL INDICATE THE TRU55 MEMBER5 0WEB5, VERTIGALS) THAT REQUIRE <br />LATERAL BRAGI%/RE5TRAINT. <br />a. T' OR 'L' BRACE: <br />WHERE BRAGING 15 REQUIRED A5 INDICATED ON SHOP DRAWING, UTILIZE T' OR 'L' BRAGE5 (REFERENCE <br />BG51-83 FI6URE5 83-18 4 B3-19). 5HOP APPLIED REINFORCEMENT PER BG51-133 FIGURE5 83-22 4 BG-23 15 <br />ACCEPTABLE. <br />• T' 4 'L' REINFORCING MATERIAL SHALL MATCH THE 51ZE OF THE WEB/VERTIGAL MEMBER. <br />• 'L' 4 T' REINFORCING TO BE A MINIMUM OF 90% OF THE LENGTH OF THE WEB/VERTIGAL MEMBER. <br />• FA5TEN 'L' OR 'T' REINFORCING TO WEB/VERTIGAL W/ Ibd GUN NAIL5 (0.131x3 I/2") AT b" O.G. <br />b. G.ONTIN0005 LATERAL BRACING ALTERNATE: <br />WHEN THREE (3) OR MORE 51MILARLY G,ONFIGURED ROOF TRU55E5 ALIGN, GONTINUOUS ROW5 OF LATERAL <br />BRAGING MAY BE U5ED IN LIEU OF THE ABOVE -NOTED 'L' OR TBRACES. <br />• CONTINUOUS ROW5 OF LATERAL BRAGING SHALL GON515T OF MINIMUM 2x4. ROW5 SHALL BE LAP 5PLIGED <br />ONE TRU55 BEYOND IN EACH DIRECTION. 5EGURE BRACE TO EACH TRU55 WMPRE55ION WEB W (2) Ibd <br />GUN NAILS (0.13101/2"). <br />• CONTINUOUS LATERAL BRACING SHALL BE RESTRAINED BY DIAGONAL BRACING (MIN. 2" THICK NOMINAL <br />LUMBER 4 MINIMUM 5PF 'STUD' GRADE MATERIAL). THI5 BRACING 15 TO BE CONTINUOU5. PROVIDE ONE <br />ROW OF DIAGONAL BRACING AT VERTICAL WEB MEMBER5 OF TRU55E5 GL05E5T TO EACH GABLE END <br />WALL 4 ADDITIONAL DIA60NAL5 AT 20'-0" A5 REQUIRED. <br />DIAGONAL BRACE NAILED TO OPP051TE <br />PROVIDE (2) Ibd NAILS o 51DE OF WEB AT 20'-0" MAX. (TO PREVENT <br />EACH MEMBER LATER MOVEMENT) DIREGT-APPLIED PLYW000/05B <br />/I ROOF 5HEATHIN67 <br />CONTIN. LATERAL BRACING <br />TO LAP ACROSS MIN. (1) <br />TRU55 BAY A5 SHOWN <br />2x 5TRON65ACK <br />(NOT REG V FOR <br />5TRUCTURE) <br />DIREGT-APPLIED <br />PLYWD/05B <br />DIRECT -APPLIED <br />GWB GEILING <br />SECTION B-B <br />ALTERNATE r MW HM 0) OR MORE SWM TRU%M ,M 6PMW <br />C <br />E. <br />DIREGT-APPLIED <br />GWB GEILING — <br />TYPICAL TRU55 ELEVATION <br />GOMPRE5510N WEB (5LOPING <br />OR VERTICAL) <br />C.ONTIN0005 LATERAL BRACE <br />ALTERNATE A (3) OR MORE <br />4-!L�� ADJACENT 51MILAR TRU55E5 (5EE <br />INDIV. TRU55 SHOP DRAWING5 <br />FOR LOCATIONS) <br />2x 5TRONG5AGK MAY BE <br />IN5TALLED FOR GON5TRUCTABILITY <br />TO KEEP EVEN 5PACI% AT <br />BOTTOM CHORD (NOT REO V FOR <br />sTRUGTURE) <br />WEB MEMBER REQUIRING <br />BRAGING A5 INDICATED BY <br />TR055 MANUFACTURER <br />2x 5TRONGBAGK5 MAY BE <br />INSTALLED FOR GON5TRUGTABILITY <br />TO KEEP EVEN SPAGING AT <br />BOTTOM CHORD (NOT REQV FOR <br />5TRUCTURE) <br />'L' OR T' BRACING o <br />NE55 DE5I6NATED BY <br />TRI, 55 MANUR <br />PERMANENT TRU55 <br />BRAG I N6 PETA I L5 4 NOTES <br />SCALE: NONE <br />DIRECT APPL.IW 0ILIN6 <br />LETTERED DETAIL5 ARE TYPICAL FOR NUMBERED DETAIL5 ARE PLAN <br />TH 15 HOME 4 5HALL BE IMPLEMENTED IN 5PEG I F I G AND ARE ONLY REQU I RED <br />ALL APPLICABLE AREAS. THESE WHERE 5PEG I F I GALLY INDICATED <br />DETAILS ARE NOT "GUT" ON THE PLANS. ("GUT") ON THE PLANS. <br />seal: <br />JUG n <br />A° V a <br />�d S ••• i % <br />© copyright "P- .0 <br />Struct�if�101k"NAI,)nc. <br />CD <br />Z <br />z <br />JLU <br />W <br />W <br />Z <br />N <br />C7 <br />Z <br />W <br />.— <br />d <br />J <br />a <br />W <br />W <br />m <br />Z= <br />F— <br />v <br />� <br />Q <br />C Em <br />W <br />Q <br />Z <br />Q <br />W <br />CI <br />:a <br />Y <br />W <br />COP)m_ <br />W <br />g N <br />M c. <br />M&K project number: <br />068-2001 1 <br />project mgr: NJ IVI <br />drawn by: JAI <br />issue date: 04-O7-20 <br />REVISIONS: <br />date: initial: <br />04/24/20 JAI <br />sheet: <br />PBSB�i <br />