Laserfiche WebLink
, WINDOW TRIM DETAIL <br />N <br />M <br />SCALE: 3/4"=1'-0" <br />WINDOW SILL DETAIL <br />SCALE: 3/4"=1'-0" <br />1'-10" <br />SCORED <br />RAISED <br />BAND <br />FOAM PANEL DETAIL <br />SCALE: 3/4"=1'-0" <br />TI(� <br />110 <br />N <br />ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP.) <br />BLDG. HEIGHT <br />65 <br />e <br />60 <br />T <br />IN <br />22"x38" STUCCO PANEL <br />DETAIL <br />ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP.) <br />4" WIDE STUCCO BAND (+1) <br />T.O. WALL 6" FASCIA <br />T.O. WINDOW <br />18" DECORATIVE FOAM <br />SHUTTERS <br />4" WIDE STUCCO BAND (+1) <br />ROOF SHINGLES PER —� <br />COMMUNITY SPECS <br />(TYP.)4:12 SLOPE <br />4" WIDE STUCCO BAND (+1) <br />T.O.2ND FL <br />FT_O_MASONRY <br />T.O. WINDOW <br />4" WIDE STUCCO BAND (+1) — <br />FIN. FLR. <br />12x12 COLUMN <br />REAR ELEVATION <br />SCALE: 1 /4"=1'-0" <br />12 <br />5 <br />5:12 <br />0 <br />12 <br />5:12 �1 5 <br />0 <br />12 <br />5 12 <br />12 5 <br />3 5 (V <br />rL <br />FRONT ELEVATION <br />SCALE: 1 /4"=1'-0" <br />CJ <br />*3050 SH cV *3050 SH <br />(V <br />_T.O.2ND FL----------------- <br />35 SH <br />min: <br />11-11MI 01 ON Fn_l FO-1 ON <br />1�411�1 <br />ROOF SHINGLES PER <br />COMMUNITY SPECS <br />(TYP•) <br />4" WIDE STUCCO BAND (+1) <br />6" FASCIA <br />4" WIDE STUCCO BAND (+1) <br />18" DECORATIVE FOAM <br />SHUTTERS <br />4" WIDE STUCCO <br />BAND (+1) <br />4" WIDE STUCCO <br />BAND (+1) <br />'jQ 8 <br />®moo <br />it <br />�o °r`_ <br />V <br />ON ALA <br />•��neeeeee,•• <br />PAINT AND FINISH SCHEDULE / KEY <br />PAINT COLOR SCHEME <br />SURFACE TEXTURE / FINISH KEY <br />BODY COLOR <br />TEXTURE <br />FINISH <br />>w:;.�. x,• Z,- , <br />....*..x•:F• .•Ix�''• <br />TRIM COLOR <br />SAND <br />FINISH <br />NOTE: WRAP THE SAND FINISH TRIM BAND (WHERE <br />SHOWN AROUND WINDOWS & DOORS) INTO THE JAMB, <br />HEAD & SILL OF THE WINDOW & DOORS. PAINT THE BAND, <br />JAMB, HEAD & SILL THE TRIM COLOR. <br />STUCCO INSTALLATION <br />STUCCO AND PORTLAND CEMENT PLASTER SHALL <br />BE INSTALLED PER THE CURRENT ASTM C926 & C1063 <br />REQUIREMENTS & PROVISIONS OF THE FLORIDA BUILDING CODE <br />STUCCO SHALL NOT BE LESS THAN 3 COATS WHEN APPLIED <br />OVER METAL OR WIRE LATH AND SHALL NOT BE <br />LESS THAN 2 COATS WHEN APPLIED OVER MASONRY <br />CONTROL JOINTS IN 3-COAT STUCCO SHALL BE USED TO <br />DELINEATE STUCCO AREAS NOT GREATER THAN 144 SQ. FT. <br />OR AT A MAXIMUM DISTANCE OF 18' BETWEEN JOINTS <br />PER ASTM C1063 (CURRENT EDITION) <br />WEEP SCREED SHALL BE INSTALLED AT ALL <br />STUCCO TRANSITIONS BETWEEN WOOD AND MASONRY <br />AS REQUIRED BY ASTM C1063 (CURRENT EDITION) <br />SHUTTER DETAIL <br />SCALE: 3/4"=1'-0" <br />, SQUARE COLUMN DETAIL <br />SCALE: 3/4"=1'-0" <br />W <br />_ CC <br />~O <br />W Z <br />O H <br />W WZ 0 <br />>Ira0 <br />W:0C)I— <br />(nUW W <br />a�W� <br />W <br />J U) W <br />lY cr cr <br />�eQH-Z <br />ui <br />Z QZQ Z ~ Z_ <br />W a 2 cr a <br />jIZLL(U <br />H Q Z <br />cz <br />c o <br />n <br />Q O <br />H <br />0 �Q <br />Q <br />O <br />O <br />cn <br />O <br />z <br />o <br />U <br />two <br />0 <br />w <br />o <br />w <br />0 <br />: <br />w <br />w <br />X <br />Now" <br />cb <br />z <br />o <br />w <br />LLO <br />w <br />O_ <br />U <br />W <br />G <br />z� <br />Z <br />O� <br />lxZ <br />aaaa <br />a <br />COMMUNITY: <br />LINKSU <br />SPRINGS <br />PLAN # 610 <br />RELEASED: 5/15/20 <br />SHEET <br />A2. 1 <br />