Laserfiche WebLink
0 <br />1'-0" <br />N <br />N_DT <br />ROOF PLAN <br />SCALE: 1 /4"=1'-0" <br />0 <br />5:12 <br />r------------ <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />5:12 <br />0 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />ct <br />I <br />I <br />I <br />a'N <br />I <br />I <br />I <br /><O <br />�p <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OFF RIDGE <br />I <br />I <br />VENT, TYP. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />---------------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />ND I <br />I <br />Lo <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />N � <br />7: <br />I <br />/ I <br />I <br />I <br />I <br />I <br />I <br />UPPER ROOF ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />1353 SQ. FT. <br />649 SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />260 SO. IN. <br />UPPER VENT 50% NET VENT MAX. <br />325 SO. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />2 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />276 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />373 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF.1 <br />57 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905, TABLE R905.1.1 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />JU! 202�J <br />IY <br />W <br />�JF-LU <br />Wz0_r <br />wLuZO <br />>cca0 <br />- <br />W::)0cc <br />UWw cn <br /><Z)ru <br />;wg <br />J <br />=5Ircc<r <br />Zz°W <br />o gQ<Z <br />w(L=CCCL <br />3 a 0 0 <br />2 Z LL U) <br />z0 <br />�F-Qcz <br />r` <br />Q <br />0 <br />O <br />U <br />O <br />0 <br />0 <br />� <br />a <br />0 <br />L,I <br />i.J <br />I <br />o <br />w <br />0 <br />w <br />m I <br />a <br />A <br />w <br />2 <br />w <br />0 <br />R <br />U <br />vI <br />04 <br />�o <br />�Zaaaaa <br />COMMUNITY; <br />LINKS ACA A <br />SPRINGS <br />PLAN # 6102 <br />RELEASED: 5/15/20 <br />SHEET <br />A3 91 <br />O <br />Z <br />w <br />cr <br />a <br />O <br />Z <br />cr <br />0 <br />od <br />Z <br />g <br />w <br />w <br />