2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />0 OR <br />2-4/0 ALUMINUM <br />150 AMP 4: <br />METER 1-3/0 ALUMINUM <br />CIRCUIT <br />MAIN <br />CIRCUIT <br />444 COPPER OR ALUM. <br />BREAKER <br />1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />mw�ll- I <br />m <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />ELECTRICAL <br />METER (V.I.F.) <br />A/C <br />DISCONNECT <br />U- <br />0 <br />a <br />ELECTRICAL KEY <br />0 DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />KEYLESS LIGHT FIXTURE <br />-�- CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />01 VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />4 EXHAUST FAN <br />i1 EXHAUST FAN/LIGHT COMBINATION <br />13 CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />�4 TELEPHONE (OPTIONAL) <br />0 TELEVISION (OPTIONAL) <br />01 ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Q JUNCTION BOX <br />�- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2014 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4.OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED ELECTRICIAN <br />TO INSURE THAT ALL ELECTRICAL WORK IS IN FULL <br />COMPLIANCE WITH N.F.P.A. 70A, FLORIDA RESIDENTIAL CODE <br />2017, NFPA 2014 AND ALL APPLICABLE LOCAL STANDARDS, <br />CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2014 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND PANELS <br />AND <br />DISCONNECTS IN COMPLIANCE WITH NEC 110.26. <br />14. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER <br />NEC 406.12. <br />15. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE PER <br />FBC E3901.9. <br />C= <br />W <br />} F_ Ill <br />�00� <br />} <br />>oCQ0 <br />W �pl- <br />cAUWw <br />Q = W_ ~ <br />tr <br />Y 0 H Z <br />odti00cn <br />ZZZF-Z <br />Lu 0- <br />OU <br />U) <br />= � IL U) <br />H Q Z p <br />c <br />O � <br />O <br />H <br />0 <br />0 <br />0 <br />0 <br />a <br />cn <br />U <br />w <br />�--� <br />w <br />a <br />u <br />w <br />j <br />w <br />w <br />a <br />O_ <br />U <br />W <br />G <br />U) <br />Og <br />Wo <br />wzQQaaQ <br />COMMUNITY: <br />UNKS @ CALUSA SPRINGS' <br />PLAN # 6120 <br />RELEASED: 6110/20 <br />SHEET <br />E• <br />