My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3555 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3555 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:39:16 AM
Creation date
2/19/2025 9:56:19 AM
Metadata
Fields
Template:
Building Plans
Street #
3555
Location
Dawson Chase Dr
Contractor
Lennar Home LLC
Building Plans - Permit #
20515
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CD <br />v <br />r.0 <br />C14 <br />O <br />N <br />M <br />t <br />00 <br />CD <br />x <br />M <br />O <br />O <br />J <br />co <br />W <br />N <br />C. <br />q <br />s <br />00 <br />O <br />co <br />12 <br />5F::� <br />T.O.M. <br />HDR HGT. <br />F.FL. --I--- ------ <br />19' RIDGE VENT <br />T.O.M. <br />4' RIDGE VENT <br />OVERHANG TO BE <br />CENTERED ON DOOR <br />12 <br />5 <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />--------------------- <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP. ) <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />1-0 <br />TEXTURED TEXTURED <br />CEMENTICIOUS CEMENTICIOUS <br />FINISH ON C.M.U. FINISH ON C.M.U. 2'-0" <br />(TYP.) (TYP.) <br />F.FL. ------------------------------------------------------ <br />REAR ELEVATION - Al <br />RIGHT ELEVATION - Al <br />: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portend cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 11300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventitated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />`"CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />C9 <br />z� <br />0 <br />�o <br />Z N <br />z� <br />a <br />U, z <br />U0 (9 <br />(V <br />W <br />C6 <br />•V — <br />OL" <br />(.n 0:� <br />m N <br />W <br />E: <br />— U <br />N M <br />Q) M <br />N W M <br />_ <br />�i <br />Ooo <br />U.o <br />U <br />C <br />o <br />Q rn <br />Q o <br />U.) <br />M Q d <br />B D.N <br />-c <br />:Jt <br />N N <br />O C'ONO <br />Z W 20? Z <br />U)YI <br />a C, rr.7 <br />W C' o zz a <br />� 3 <br />Cnin o <br />Z 2 ¢ O <br />C N O pa <br />Z N� � Q <br />LL ul <br />s <br />C, •�E �Co.. <br />NZZ <br />•; <br />Q <br />0. <br />V ;• ��� <br />s � <br />F�� <br />lZfR <br />O F E S S``O <br />flt4�i1 <br />e\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2017 Flodde Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />L E N N A R <br />4600 W. Cypress St, Suite 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />06 <br />�o <br />C/) <br />z <br />W¢�� <br />O!r <br />80 <br />z <br />F— <br />U Z <br />Lu <br />cy¢� <br />Oo Lu <br />T yf g J <br />a d 0 <br />W <br />0 <br />"��io <br />_I <br />oV) <br />L <br />W <br />�j/ <br />I z <br />Z <br />p <br />U <br />= <br />Q <br />< <br />DWI` <br />9� <br />>9 <br />P Y Pa <br />I— a <br />L0 <br />SOJ <br />O a <br />' /) <br />u ) <br />may-• <br />LL <br />0 <br />N <br />Z<Z� <br />wE2a' <br />¢aL'U� <br />0 � <br />Z <br />20'° <br />z <br />J <br />•�-+ <br />LO <br />di <br />a Z � <br />a Z <br />ri <br />L1..1 <br />Q <br />z <br />a <br />LU <br />� Ce z <br />ry) <br />z <br />U <br />�zo <br />�o <br />0 <br />OU <br />Z <br />� <br />2 <br />�� <br />`Lu <br />0 <br />t1 <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />3.2 <br />U1 <br />UA <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.