Wffk <br />00 <br />u7 <br />it <br />N <br />0 <br />J <br />00 <br />2 <br />E <br />0 <br />.% <br />.00 <br />0 <br />kd <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED, LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />1 <br />20000 AMP #12 copper to 20 amp ckts <br />A <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN <br />"`L. <br />O210 <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />==r <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />R4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />}� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />,Or <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60"A.F.F. <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />WWI_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />'7 <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=V-Orr <br />i <br />1.. a <br />0 V <br />Z o <br />Z `fl <br />Z <br />Q <br />t1 <br />Z <br />^V)^ , <br />�W N <br />w <br />_moo <br />�V — <br />O w <br />~ <br />�� = <br />o <br />co <br />RS U <br />Co <br />W <br />— <br />N co <br />co <br />_ <br />C N <br />o <br />�o <br />00 <br />CnQo <br />�, gd <br />rn Q d <br />B DO <br />N-C <br />10 <br />N �O <br />10 <br />v. O CM <br />Z <br />U) W -5 .5 z <br />� � v5 <br />rj�-o <br />W a oi <br />Lu �. zz <br />Z O _ 4Q= a O <br />v N O W <br />LLW N¢ M C a <br />o v V O <br />WWW.FDSENG.COM <br />cw <br />0 <br />N <br />N <br />O <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0z <br />ujw <br />I� <br />Z <br />J <br />w ¢ � Of <br />oW¢8o <br />�.. <br />z � <br />�oWZ <br />J0 <br />_j � <br />�0 <br />'Q <br />c) <br />Sm�o <br />on <br />L <br />Z O <br />z <br />W <br />J <br />^^ <br />1..1.. <br />W <br />.� <br />-� <br />✓r <br />U <br />O� <br />�Oo <br />J .." <br />o � <br />1'�"I <br />� <br />J <br />V.- <br />� 6 <br />Ho <br />.�'..Lr) <br />z <br />�m <br />V ae <br />- l i <br />¢¢gam <br />W Z <br />a�Qg5, <br />$o <br />Z <br />Z <br />r` <br />o <br />< 2 Z <br />UJI <br />L0 <br />tJJ <br />a "o <br />T—i <br />LL <br />w <br />gFl- <br />M <br />Q <br />Z <br />g�<Z <br />Ion <br />�Q <br />z <br />W <br />J9 <br />W <br />� <br />a_ <br />Cn <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />