W <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & WEATHER RESISTIVE <br />a TEMPORARILY SECURE BARRIER WINDOW UNIT <br />DOOR ROUGH OPENING <br />o WEATHER <br />SLOPE <br />RESISITIVE <br />o BARRIER WOOD FRAME CONSTR. O.3 In : 12.0 In <br />N <br />TAPE EXTERIOR SELF -ADHERED FLASHING :'i:2:F':i>`: 3/4"-1" BEAD OF CONSTR. (0.6 cm: 30.5 Cm) <br />3 s SHEATHING BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />OVER RIM JOIST AND P THRESHOLD OF DOOR AND RETURN <br />U <br />WALL BY 6 IN. <br />(ASSEMBLED WINDOW) �:::.:,::-°-"--- - UP JAMB 6". USE LIQUID NAIL BRAND <br />_. " EXTERIOR <br />OR EQUAL WEATHER PROOF CAULKING <br />CEMT. FIN. <br />WEATHER-_ <br />- :- -._. <br />"``£_ SELF -ADHERED FLASHING BUILDING PAPER <br />a <br />iu - RESISITIVE <br />9 2 - BARRIER <br />SEAL TOPS OF JOISTS _ WIRE LATH <br />UNDER DECKING :.op <br />SUBF <br />(SEE DETAIL WP07) LOOR <br />SELF -ADHERED FLASHING =n <br />3 HEAD FLASHING TIE-IN INSTRUXTIONS: J. <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier 1 1 <br />3. Fold weather resistive barrier back over head 2 2 O <br />flashing and seal with tape <br />a <br />g Scale: NTS <br />SELF -ADHERED FLASHING WP01 <br />WPO� SELF -ADHERED FLASHING SELF -ADHERED FLASHLNG��03 <br />te <br />FLANGED WINDOW <br />EXTERIOR DOOR WITH DECK - SECTION A CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />U) <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />EXTERIOR SHEATHING 3/4"-V BEAD OF CONSTR. INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />�I ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD THROUGH SELF -ADHERED <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING SELF -ADHERED FLASHING <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />99 <br />SEE DETAIL WP01 <br />sc;......:c::_ <br />OR EQUAL WEATHER PROOF CAULKING - <br />a <br />REFER TO CAL TECHNI --- - -- --- <br />LETTER ON CHEMICAL '. .::: SCORED:. ' <br />COMPATIBILITY ::;::t.`:::s;;;::.:. <br />. RELEASE PAPER <br />SELF -ADHERED FLASHING BEFORE FOLDING SCORE <br />SELF -ADHERED FLASHING, <br />�o <br />RELEASE PAPER TO EXPOSE <br />EXTEND A MINIMUM 6" ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />0 <br />SECTION -A (SEE DETAIL WP02) <br />DO NO- <br />BOTTO <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />f LI l IIIYV <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />LASHING <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />WP04 <br />E <br />AM <br />WP07 <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED I WP101 NOT USED <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />WP1 1 <br />6�1 <br />1�� <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />2 <br />5 <br />4 <br />6 <br />7 <br />T1'Ii <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />A SIN <br />d _ d G <br />d <br />2 , <br />d a- <br />,: a <br />d G <br />Foundation Wall .d d <br />a. <br />"ddb a a. <br />d d <br />d <br />FOUNDATION WEEP SCREED <br />NOT USED <br />WP09 <br />WP121 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds <br />to the numbered items in the ist of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing <br />material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing <br />accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />1. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />FLASHING REQUIREMENTS <br />R612.12 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows <br />shali comply with Section R703.8. <br />R703.2 Weather -resistant sheathingpaper. One layer of No.15 asphalt felt free from holes and <br />P p Y p breaks, complying with ASTM D 226 for Type 1 felt or other approved water - <br />resistive barrier <br />shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be <br />applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 <br />mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other <br />approved material shall be continuous to the top of walls and terminated at penetrations and <br />buildingappendages in a manner to meet the requirements of the exterior wall envelope as <br />q op <br />described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a <br />manner to prevent entry of water into thewall cavity or penetration ofwater to the building <br />structural framing components. Self -adhered membranes used as flashing shall comply with <br />AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved <br />corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall <br />extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent <br />drainage. Flashing at exterior window and door openings shall be installed in accordance with <br />one or more of the following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.15 Drained assembly wall over mass assembly wall. Where wood frame or other types of <br />drained wall assemblies are constructed above mass wall assemblies, flashing or other <br />approved drainage system shall be installed as required by R703.8. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />-Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1 /2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />�J <br />i <br />to <br />-Cu <br />U <br />O <br />O <br />a <br />� <br />O <br />�--+ <br />N <br />U) <br />-� <br />CUCUCn <br />O <br />p <br />S� <br />C <br />i <br />Q <br />fU <br />O <br />LL <br />CU <br />O <br />tZ <br />I.-> <br />O <br />to <br />N <br />- <br />-' <br />CU <br />E <br />Z <br />Z <br />UJ <br />J <br />U <br />s � <br />CIO <br />a3 <br />O <br />0- <br />0 <br />♦--+ <br />O <br />O <br />U) <br />co <br />W <br />�C <br />Z <br />Z <br />Q <br />J <br />a <br />SHEET NO. <br />WP1,0 <br />In <br />