My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36034 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36034 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 6:02:44 PM
Creation date
2/19/2025 9:56:52 AM
Metadata
Fields
Template:
Building Plans
Street #
36034
Location
Stable Wilk Ave
Contractor
Lennar Home
Building Plans - Permit #
18705
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />UNLESS OTHERWISE NOTED <br />ELECTRICAL DETAIL: <br />ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN B <br />1/4 if = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0" <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />2011 NFPA 70 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER 2011 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2011 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A)BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 410 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to Tooter steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />DOOR <br />JAMB <br />TRIM <br />BASE <br />TRIM <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />io <br />-SWITCH <br />1/2" <br />DUPLEX _ <br />OUTLET <br />Fo <br />0 <br />0 <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />6 SWITCH AT 36" <br />69 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />�B} CLG MNT PREWIRE - FIXTURE BY OWNER <br />C} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />O 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB(SHOWER CANS MAY BE <br />®' 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />RECESS CAN OR LED OWNER <br />' 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />cM COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />s0 SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />24 � 24" VANITY LIGHTING <br />36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />® EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />O 150W PAR 38 FL <br />INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W( INTERCOM) <br />® MASTER STATION <br />® ELEC PANEL <br />0 VACUM OUTLET AT 12" <br />L/RACEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />T1) THERMOSTAT <br />TPI SECURITY PAD <br />CTI ELEC METER <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSES. <br />SIN, <br />> O0 N'011 <br />o <br />� <br />� N <br />tN <br />V <br />70 c <br />� <br />r-` <br />_ <br />t o <br />O <br />75 <br />2 o <br />� <br />•:/i <br />s <br />U 6' <br />� <br />� <br />� <br />W Q <br />v <br />C <br />^` <br />W <br />L <br />w <br />0 EM <br />� a <br />�0 <br />LLjwQ�2Qm3 <br />w <br />i— <br />�6 wO~wwvwgYZLJ o' <br />0wn�-00° <br />QQ<Wa <br />'OX�uiw2z200,�~ <br />�Zu)w <br />wo_ <br />OROOMOZ <br />- Zw UJa <br />V <br />a <br />¢ <br />oZ <br />wwoWO¢0<QzZw <br />ooe� <br />¢ <br />oQ9Q¢LL <br />F <br />O <br />_u- <br />co <br />N <br />O <br />N o <br />Lo <br />0 <br />qql- -0 <br />N � <br />L/ <br />V ) <br />N <br />O <br />fy <br />O 0 <br />m <br />z <br />wM <br />Zo <br />-Ji <br />C <br />Q <br />Z <br />Z <br />LU <br />J <br />CD <br />0 <br />(V <br />N <br />4 <br />O <br />c <br />O <br />C) <br />LU <br />1- 4 <br />r< <br />V <br />00 <br />M <br />N <br />O <br />O <br />N <br />Z <br />O� <br />> (n o 0 <br />0 M O <br />Q M P, <br />���ti <br /><w<Lo <br />co <br />T <br />Q U Q 00 <br />Z I- <br />W <br />J O <br />O <br />d' <br />We <br />LAST PLOT DATE <br />Jun. 26, 17 <br />v <br />Q W (q <br />W�- <br />WU�� <br />� 0 CL <br />ZWF- <br />WI.- <br />� <br />~000¢ <br />z <br />=I-=z <br />Lz <br />��z�azz <br />0 (L w <br />�zz <br />�a0 <br />U <br />1ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />B <br />z <br />z <br />W <br />J <br />0 <br />0 U <br />
The URL can be used to link to this page
Your browser does not support the video tag.