Laserfiche WebLink
�_ 1 t _. 11 �_ - 101 1 1 ■ � .1 I -. ____ _ 1 ■ '1� 1 1 1 <br />12 <br />(TYP-) VARIES <br />(1) LAYER TYPE II (#30) <br />UNDERLAYMENT FOR <br />ROOF PITCH 4:12 OR GRATER & <br />(2) LAYERS TYPE 1(#15) OR <br />TYPE II (#30) UNDERLAYMENT <br />FOR ROOF PITCH BETWEEN 2:12 <br />& 4:12. PER FBC R905.2.7. <br />PRE ENGINEERED WOOD <br />TRUSS @ 24" O.C. U.N.O. <br />HURRICANE ANCHOR @ EACH <br />TRUSS (SEE UPLIFT SCHED.) W/ <br />METAL PL. UNDER EA. TRUSS <br />MOISTURE BARRIER <br />SHINGLE ROOF <br />7/16" O.S.B. MIN. SEE ROOF <br />NAILING SCHEDULE ON SHT. <br />5/8" OR 1/2" HIGH <br />ALUMINUM DRIP <br />STRENGTH CEILING <br />EDGE <br />BOARD PER CODE (OR 5/8" <br />GYP. TYPE "X" @ GARAGE <br />ALUMINUM FASCIA <br />W/A HABITABLE ROOM <br />12" N.O. 2x SUB FASCIA <br />ABOVE) W/DRYWALL <br />EE SOFFIT <br />SCREWS @ 7" O.C. <br />SHEET <br />CEILING & 8" O.C. WALLS <br />8"x8"X16" KNOCK -OUT <br />INSULATION PER <br />BLOCK W/ 1#5 CONT. <br />CHART ON SN1 <br />FILLED SOLID W/GROUT <br />1x2 P.T. HORIZONTAL <br />NAILER <br />8" C.M.U. TYPICAL <br />STD. 90-HOOK (SEE DETAIL) <br />TYPE "S" MORTAR <br />ARCHITECTURAL <br />FINISH <br />1x2 PT WD FURRING @ 24" O.C. <br />1/2" GYPSUM WALLBOARD <br />U.N.O. <br />1x4 P.T. BASE NAILER <br />31/4" BASEBOARD <br />MIN. 2500 PSI CONC. SLAB <br />CIO MIN PSI MAY VARY PER <br />MUNICIPALITY. <br />CONCRETE SLAB W/ 6X6 <br />W1.4XW1.4 WWF OR <br />"FIBERMESH" <br />c <br />E <br />T=11=J=fill <br />co) <br />D <br />6 MIL VAPOR I I D <br />BARRIER <br />COMP. SOIL. 1 ° <br />(COMPACTED TO 95% <br />MODIFIED PROCTOR <br />ASTM D1557) <br />(2) #5 REBAR CONT. 3" MIN. CLR. <br />ON 3" CHAIRS TYP. 4" 1'-4" STD. 90 HOOK (SEE <br />U.N.O. DETAIL) <br />TYPICAL WALL SECTION tASCALE: 3/4"= V-0" <br />OPT: DEPRESS SLAB 5Y2" DEEP <br />AND 6" BEYOND DOOR TO - <br />RECEIVE PAVERS / DRIVEWAY <br />CONCRETE SLAB <br />PAVERS <br />BLOCK WALL BEYOND <br />14" O.H.D. RECESS <br />Z <br />iy <br />-- J <br />a 4" II <br />e op <br />T <br />I I� <br />+` .IIF <br />.� 1111 <br />SEE A/S3 OR J/S6 -- -I j I 11111 I I_1 1„ I I 11' -I'T <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1' " (1 STORY) / 1'-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1' 8" (2 STOR <br />GARAGE DOOR SLAB RECESS J.1 <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />2x #2 SPF STUDS - <br />@16" O.C. W/ (2) <br />16d TOENAILS T & B <br />2x P.T. PLATE --\ <br />(2) #5 CONT. ON 3" <br />CHAIRS (TYP.) <br />D ' <br />�f-l- II m <br />It> <br />I <br />(1) ROW 2x BLOCKING @ MID <br />HGT. FOR WALL HGT. s 8'-6". (2) <br />ROWS 2x BLOCKING @ 3rd PTS <br />FOR WALL HGT. > V-6". <br />1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z <br />APPLICABLE. <br />1/4" DIA. X 31/4" TAPCONS @ 24" O/C & ci <br />@ 6" MAX FROM END OF 2 x PLATE E <br />N <br />6x6W1.4xW1.4 r <br />WWF OR FIBERMESH I `' <br />° . 1�1 - <br />E1 11@A11'�1' <br />TYPICAL INTERIOR BEARING <br />WALL W/OUT UPLIFT rGG <br />SEE TYP. WALL SECTION <br />FOR ADDITIONAL SLAB <br />INFORMATION. <br />SCALE:3/4"=1'-0" S3 <br />8"x8"x16" NOMINAL BLOCK WITH <br />3/8" MORTAR BETWEEN COURSES <br />3/8" MORTAR BETWEEN <br />SLAB & BLOCK <br />c <br />ELEV. 0'-0" <br />OL <br />o A.F.F. <br />A <br />a °.. a '' a . ELEV. -0'-31/2" z <br />A.F.F. o <br />2x4 CONT, o- ' <br />c U- <br />° . p <br />CN <br />° GARAGE DEPTH VARIES ° <br />GARAGE SLAB AT STEP rB�'� <br />SCALE: 3/4"=V-0" <br />2x S.P.F. STUDS @ 16" O.C. <br />LOAD BEARING OR Zx STUD <br />EXTERIOR WALL 8" C.M.U. <br />1"x P.T. STUD <br />SEE CC/S3 OR i`vV #5 VERT. IN FILLED CELL <br />G/S3 FOR ANCHOR <br />BOLT INFO. 5/8"x6" "J" BOLTS BOLT <br />(IF NO UP LIFT ON @ 24" O.C. VERT. OR <br />WALL SEE GG/S3) 5/8" x 6" EPDXY BOLT OR <br />*USP SPT22 TYP. (6) 1/4"x3 1/4" TAPCONS <br />SPACED EVENLY <br />r 2x P.T. PLATE <br />ASSUMED FINISHED <br />GRADE <br />MONO OR STEMWALL z <br />FOOTING MONO SHOWN00 <br />FOR CLARITY ° D ' <br />° I� 11=1 11=1 I �I 11=1 II <br />°t. <br />NOTE: g ° III-1 I-1_TI-1 I I-1 ICI I N <br />*FOR BEARING WALL I=III— I I —I I 111=I11 r <br />W/ UPLIFT ONLY — — <br />I-1 I C I I�TI=IZT---= I— I—T� I I-1 11=1 I H I I---TI f=• I <br />FRAME WALL TO C.M.U. WALL CONNECTION D <br />SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=1'-0" S3 <br />SLAB INFORMATION. <br />BLOCK WALL BEYOND <br />EXPANSION JOINT <br />171 <br />13 O.H.D. RECESS <br />T M ' <br />c <br />Ch °-' .. _ <br />1-1 <br />—I� I II=III :'• <br />' I I -I I I —� <br />SEE A/S3 OR J/S6 11F, 1 I I I 1 i 1111 l I l 11 �' <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 STC iRY) <br />1'-8" (2 STORY) <br />GARAGE DOOR SLAB RECESS ri <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />S3 <br />5/8"OR 1/2" HIGH STRENGTH <br />(U.N.O.) (OR %" GYP. TYPE "X" V <br />GARAGE W/A HABITABLE ROOM <br />ABOVE) <br />S.P.F. DOUBLE <br />TOP PLATE <br />USP SPT24 <br />CONNECTOR <br />1/2" CDX PLYWOOD OR 7/16" O.S.B. I j <br />SHEATHING REQ'D. FOR ALL <br />EXTERIOR OR SHEAR WALLS AS <br />INDICATED ON THE PLAN. ATTACH <br />SHEATHING W/ 8d COMMON NAILS @ <br />4" O.C. @ BOUNDARIES, 6" O.C. @ <br />EDGES, AND @ 12" O.C. @ FIELD <br />5/8" x 10" "J" BOLT @ 24" O.C. W/ <br />2""x3/16" PLATE WASHER (TYP.) <br />(ALT: 1/2"xl2" TITEN HD @ 24" <br />O.C. OR 5/8"x10' WEDGE ANCHOR <br />@ 24" O.C.) 2" <br />�31/2" MIN. <br />b . <br />D ° <br />P •' c <br />TRUSS BOTTOM CHORD OR 2x4 BLOCKING <br />W/ 2-16d TOE NAILS @ EACH END <br />SEE UPLIFT SCHEDULE FOR UPLIFT <br />CONNECTIONS. PROVIDE (1) USP HTW20 WHEN <br />TRUSS ALIGNED WITH STUD BELOW <br />2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. <br />(1) ROW 2x BLOCKING @ MID HGT. FOR WALL <br />HGT. < V-6". (2) ROWS 2x BLOCKING @ 3rd PTS <br />FOR WALL HGT. > 8'-6". <br />INSULATION PER CHART ON SN1 <br />USP SPT22 CONNECTOR <br />2x P.T. BOTTOM PLATE <br />6x6W1.4xW1.4 <br />WWF OR FIBERMESH <br />31/2"(min.)- 4" I I=1 ( I I 11=1 I I- <br />-I��I- <br />- <br />(2)#5CONT. � �I <br />4 1-4 8 <br />U.N.O. MIN. <br />TYPICAL BEARING WALL as STEP an SHEARWALL <br />"SHEAR WALL" <br />SCALE: 3/4"=V-0" <br />�Oos�G <br />112" OR 7/16" OSB MIN. PLYWOOD SHEATHING ALL LATH AND LATH ATTACHMENTS TO �s't1E <br />NAILED W/ 8d COMMON NAILS @ 4" O/C BE OUT OF CORROSION -RESISTANT <br />BOUNDARIES, 6" 0/C EDGES, AND 12" 0!C FIELD. MATERIALS <br />SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. MAN o� <br />(2) ROWS OF 2x BLOCKING @ 2x STUDS @ 16" O/C <br />THIRD POINTS I <br />INSULATION PER CHART ON SN1 <br />"STUCCO FINISH PER ASTM C. 926 APPLY 3 <br />LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL <br />5/8"" x 10" "J" BOLT @ 24" O/C W/ 2"°X 3116" <br />PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. @ K.O. BLOCK <br />MIN. 2500 PSI CONCRETE SLAB W/ SP SPT22 @ EA. STUD <br />6 x 6 W1.4 x W1.4 WWF OR 2X P.T. PLATE 20" MIN. LAP [24" MIN. LAP] <br />5/8"OR 1/2" HIGH STRENGTH — <br />(U.N.O.) (OR %8" GYP. TYPE "X" @ <br />GARAGE W/A HABITABLE ROOM <br />ABOVE) <br />S.P.F. DOUBLE <br />TOP PLATE <br />USP SPT24 <br />CONNECTOR <br />5/8"" x 10" "J" BOLT @ 24" O.C. W/- <br />2""x3/16" PLATE WASHER (TYP.) <br />(ALT: 1/2"x12" TITEN HD @ 24" <br />O.C. OR 5/8"x10' WEDGE ANCHOR <br />@ 24" O.C.) <br />31/2" MIN. <br />TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ <br />2-16d TOE NAILS @ EACH END <br />SEE UPLIFT SCHEDULE FOR UPLIFT <br />CONNECTIONS. PROVIDE (1) USP HTW20 WHEN <br />TRUSS ALIGNED WITH STUD BELOW <br />—2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. <br />--(1) ROW 2x BLOCKING @ MID HGT. FOR WALL <br />HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS <br />FOR WALL HGT. > 8'-6". <br />—INSULATION PER CHART ON SN1 <br />—USP SPT22 CONNECTOR <br />/2x P.T. BOTTOM PLATE <br />6x6W1.4xW1.4 <br />WWF OR FIBERMESH <br />go <br />31/2"(min.) - 4" =1 I=1 I <br />ICI —I <br />c I <br />(2) #5 CONT. 4■ I I I—I� I I h 111811= <br />U.N.O. MIN. <br />FIBERMESH #5 REINFORCING <br />1 EEP SCREED INSTALLED BAR — <br />c PER MANUF. #3 OR #4 REINFORCING BAR <br />D . D GRADE 40 MIN. Fy= 4Cksi <br />N ° z_ #3 & #4 LAP SPLICE <br />° p FINISH GRADE °O 25"MIN. LAP 0"MIN. LAP][GRADE 60 MIN. Fy= 60ks7 <br />-0 [� <br />00 <br />6 MIL VAPOR BARRIER -I I I D ° ° 11� 11= 11� I —_ R 1 7/8" <br />I I I� I I-E I—. #5 REINFORCING BAR <br />I II—III—II1=11I—III r <br />' 1 I I •' I I—� I ]—I I I —I w <br />COMP. SOIL. (COMPACTED TO I I II I ° a - — 11� <br />95% MODIFIED PROCTOR ASTM <br />D1557) I I I II I I I I �I IJ 1 11— <br />411 <br />TYPICAL EXTERIOR FRAME WALL FOOTING <br />SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" <br />SLAB INFORMATION. <br />P.T. 2x <br />1/2" GYP. BD. <br />2„ <br />HOLD GYP. BD. <br />1/2" FROM SLAB <br />0'-0" J <br />CONT. BEAD SEALANT <br />'dLINTERIOR <br />2X STUDS @ 24" O.C. U.N.O. <br />A. <br />GARAGE <br />CONCRETE NAILS W 1 1/2 <br />1/2" GYPSUM WALLBOARD U.N.O. <br />EMBEDMENT @ 12" O.C. <br />W/ DRYWALL SCREWS @ 8"O.C. <br />STAGGERED, FROM BOTTOM <br />INSULATION PER CHART <br />PLATE TO CONCRETE <br />ON FLOOR PLAN <br />(MIN. SHEAR 180# MIN. <br />CONT. BEAD SEALANT <br />TENSION 120#) <br />CONCRETE SLAB <br />E <br />= 6x6W1.4xW1.4 <br />M WWF OR FIBERMESH00 cn <br />c <br />F_ <br />iv <br />III <br />° <br />° <br />6 MIL VAPOR <br />— <br />I 11= I 11=1 11=1 11=1 11=1 I I <br />BARRIER <br />—1 I I I <br />1111 111 <br />I I <br />411 4" <br />INTERIOR WALL SLAB STEP NON-BRG. K <br />SCALE:3/4"=1'-0" S3 <br />6x6W1.4xW1.4 <br />31/2" WWF OR FIBERMESH <br />min. 4" <br />co ° <br />I� I_I_- FEE I I 11= I I I I <br />�I="I ICI I I II 1 I ( ) <br />' I11 III— I I I I� I I I SCREEN <br />I I I 111 I I I I=1 I I I 1 11 1I- <br />MIN. <br />TYPICAL THICKENED SLAB EDGE L <br />SCALE:3/4"=1'-0" S3 <br />GRADE <br />-1 #5 REBAR W/OPT. <br />1 1/2" RECESS FOR 6 x 6 W1.4 x W1.4 <br />S.G.D. (U.N.O.) WWF OR FIBERMESH N <br />T •C <br />M G <br />d <br />° III III; <br />II II II I Ir I I II I . <br />M 1.II I' <br />—___ 1111 <br />SEE A/S3U/S6 - 11 1i,�--rl I 111 "� I8" <br />FOR REINF. INFO. OPTION #1 <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />SLAB INFORMATION. <br />SLAB STEP & RECESS S.G.D. rM <br />SCALE:3/4"=V-0" S3 <br />1/2"(min.)- 4" <br />TYPICAL BEARING WALL @ STEP CC <br />SCALE:3/4"=l'-0" S3 <br />NOTE: <br />SEE SECTION C/S3 FOR <br />ADDITIONAL INFORMATION <br />USP SPT22 CONNECTOR <br />2x P.T. PLATE <br />SPACE ANCHOR <br />BOLTS 6" MAX FROM <br />w END OF 2" x PLATE <br />� D <br />w <br />a <br />5 1— <br />co —I I I I 1 I I=1 1 I- <br />#5 CONT. =1 I H 1 <br />ON 3" CHAIRS <br />8" 1'-411 <br />(TYP.) <br />(1) ROW 2x BLOCKING @ MID HGT. <br />FOR WALL HGT. s 8'-6". (2) ROWS <br />2x BLOCKING @ 3rd PTS FOR <br />WALL HGT. > 8'-6". <br />-1/2" GYP. WB (MIN.) @ GARAGE <br />SIDE IF APPLICABLE. <br />-5/8'~ EXPANSION BOLT @24 " O.C. <br />W/ 7" EMBEDMENT (MIN. SHEAR <br />3500#, MIN. TENSION 2600#) <br />E <br />6x6W1.4xW1.4 <br />WWF OR FIBERMESH <br />CM 1 <br />81, <br />I I-1 I rr' <br />II III=111=111=' <br />I <br />TYPICAL INTERIOR BEARING <br />WALL W/ UPLIFT rG <br />SCALE: 3/4"=V-0" S3 <br />MASONRY WALL AND <br />PAD FOOTING <br />8" MASONRY WALL EXTEND FILL CELLS c <br />TO FOUNDATION PAD <br />CONT. FOOTING STEEL MAT REINFORCING. <br />M <br />coGRADE a ° <br />. <br />w —III-1 I I-1 I I-1 I I Lu <br />oo`n= I I�II�I Zz <br />• °• <br />LL U ° ° OOTING -J <br />11=1 I I I=1 I I=1 11=1 I I I— U <br />I11-I1�I I W I I I I ...I 11-1 I I=' BEYOND <br />PAD REINFORCEMENT ' -III—I 11—III—' '- <br />3" MIN. CLEARANCE <br />(SEE SCHEDULE) FOOTING WIDTH <br />SEE SCHEDULE <br />PATIO COLUMN FTG. DETAIL rN <br />SCALE: N.T.S. S3 <br />V/ <br />2 1.1 <br />~ U <br />of <br />W <br />11 <br />wa <br />a <br />r` <br />C� <br />L3LI (L a <br />p <br />= <br />~ <br />N <br />N <br />wC)0 <br />gW <br />J <br />aW�a <br />`-m .., <br />°° <br />=z <br />Z <br />0o .N. <br />aI,_Zp <br />�oW <br />I— <br />r dZ <br />, <br />z- <br />w <br />LL <br />Lu 0 <br />f <br />p <br />p}pZ=Z <br />W w2mp <br />`Q�' ' `'� <br />uj <br />=w~� <br />-p?sm <br />__' <br />HF- <br />(/A� //W�, E <br />C %O r2 U <br />M C4 <br />} M <br />N V _0_0 00 <br />O.)A� <br />Ccn <br />f <br />>` z p <br />� W ° 0 2 8 <br />a: c <br />�.0 U 0 < <br />dg <br />V w Q:;� <br />s` o E M rn <br />a ) <br />W <br />Ww <br />wa <br />°�wwUOoo <br />W <br />°W� <br />Qz <br />zW <br />WV <br />Q Z-) <br />CxJLL <br />�,�c-JQMQQi <br />moz <br />(y O O <br />cn O� Z <br />_j Lu (9a;zYOZz-o<0 <br />a$W°Q�= <br />a' <br />mwama a <br />wa O <br />maw <br />i <br />O <br />04 <br />Z w <br />0� <br />> (n O <br />O1.4 <br />Q M <br /><�('M <br />< >- <co <br />~ <br />Z <br />W <br />Jc:) <br />(O <br />lot <br />(o <br />0 <br />CV <br />C6 <br />N <br />O <br />N <br />O <br />0 <br />> <br />L0 <br />O <br />Z z <br />O <br />� <br />Wwv) <br />Q <br />Uo[:o <br />W <br />uj <br />W <br />VJ <br />i <br />U <br />ZW~a <br />H <br />w <br />I..L <br />z <br />aV <br />t <br />Z 3 J <br />/ <br />C Lu 0 <br />aZZ <br />r- <br />w <br />Og2W <br />O <br />¢ M <br />U�Z� <br />.. <br />z cV <br />�Qo <br />se <br />Z <br />U <br />U <br />a <br />M0 <br />W <br />a <br />z <br />z <br />CN <br />a <br />Co <br />LAST PLOT DATE <br />May. 23, 17 <br />O <br />STRUCTURAL <br />J <br />1 <br />DETAILS -MONO <br />(1) #5 VERT. IN FILL <br />CELLS (SEE <br />FOUNDATION PLAN <br />FOR LOCATIONS) <br />4"x4"INSPECTION <br />PORT AT EACH <br />FILLED CELL TYPICAL <br />AT GARAGE CONTRACTOR <br />TO CUT BLOCK OR POUR <br />CURB DUE TO SLOPE <br />a <br />NOTE:EXTEND <br />DECO FINISH 4" to 6" <br />BELOW GRADE <br />I� <br />N <br />