Laserfiche WebLink
FOLD UP WEATHER <br />RESISTTEMPOIRARIL VE YSECURE B IER RESISTIVE WINDOW UNIT <br />DOOR ROUGH OPENING <br />$ WEATHER SLOPE <br />RESISITIVE <br />s BARRIER WOOD FRAME CONSTR. O.3 In : 1 Z.O In <br />N 0.6 cm: 30.5 cm <br />TAPE EXTERIOR ( ) <br />a SHEATHING SELF -ADHERED FLASHING :»: >::::>::::»." 3/4"-l" BEAD OF CONSTR. <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND <br />(ASSEMBLED W NDOW) EXTERIOR <br />® 2 3 OR EQUAL WEATHER PROOF CAULKING <br />CEMT. FIN. <br />8 WEATHER z SELF -ADHERED FLASHING BUILDING PAPER <br />m ' RESISITIVE <br />3 s BARRIER SEAL TOPS OF JOISTS WIRE LATH <br />UNDER DECKING - <br />r (SEE DETAIL WP07) SUBFLOOR <br />SELF -ADHERED FLASHING <br />0 <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />barrier above header to allow for flashing <br />3 installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 21 VO <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />r FLANGED WINDOW WP01 EXTERIOR DOOR WITH DECK - SECTION A WP02 CEMT. FINISH SILL/ POTSHELF/CHIMNEY SHOULDER WP03 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />t NEEDED IN CORNERS ADHESIVE <br />EXTERIOR SHEATHING 3/4"A" BEAD OF CONSTR. INSTALL SELF -ADHERED THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD FLASHING <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE SELF -ADHERED FLASHING <br />v FLANGED WINDOW <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />m' OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />o REFER TO TECHNICAL SCORED <br />LETTER ON CHEMICAL ° <:'� :;::?:":<::::;. RELEASE PAPER <br />COMPATIBILITY'::::: .:.::......:::::::.::::::.::. <br />� (BEFORE FOLDING, SCORE <br />SELF-ADHEREDFLASHING SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE <br />°:srr::";t:•:;>:ata;;:. ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />.:;::::;:;:t::t.-:::.s-::<::a:::;::::.-:.::'::::..::::.::.:.•:::::.:::... <br />BOTTOM F.... <br />:.-....:.: <br />...:..z:THRESHOLD <br />.. :•:;{i?ik:;:': p:cF{;i:i•::..'T:::.':::?:.:.3 •`!S:i{.lifji)1:... ° . ' <br />SECTION -A (SEE DETAIL WP02) <br />DO NO' <br />BOTTO <br />cl AW(_I <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />4SHING <br />WP04 <br />E <br />AM <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />0 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />rLmani a rv^annw _ <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />DECK JOIST FwP07 OUTSIDE CORNER <br />d <br />WP05 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />p A A <br />d Oa 2 , <br />n <br />n ed <br />..a .� O <br />Foundation Wall .A A • <br />4 <br />. d <br />e <br />FOUNDATION WEEP SCREED <br />NOT USED I WP101 NOT USED I WP111 NOT USED <br />2 <br />5 <br />4 <br />6 <br />7 <br />WP06 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />WP09 <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW <br />GENERAL FLASHING AND WATERPROOFING METHODS TO BE USED. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as l # J in each detail that corresponds <br />to the numbered items in theist of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water <br />shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on <br />demand, embedded in the adhesive layer) - for ease of <br />installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions <br />and adhere to substrate using a square piece of flashing <br />material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing <br />accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1 /2" to 2" <br />Above Roof <br />Sheathing <br />FLASHING REQUIREMENTS <br />R612.12 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows <br />shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and <br />breaks, complying with ASTM D 226 for Type 1 felt or other approved water -resistive barrier <br />shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be <br />applied horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 <br />mm). Where joints occur, felt shall be lapped not less than 6 inches (152 mm). The felt or other <br />approved material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as <br />described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a <br />manner to prevent entry of water into thewall cavity or penetration ofwater to the building <br />structural framing components. Self -adhered membranes used as flashing shall comply with <br />AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved <br />corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall <br />extend to the surface of he exterior wall finish or to the water -resistive barrier for subsequent <br />drainage. Flashing at exterior window and door openings shall be installed in accordance with <br />one or more of the following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with <br />projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame <br />construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.15 Drained assembly wall over mass assembly wall. Where wood frame or other types of <br />drained wall assemblies are constructed above mass wall assemblies, flashing or other <br />approved drainage system shall be installed as required by R703.8. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />,Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1 /2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />tD <br />i <br />cn <br />_ <br />O <br />U <br />C <br />-o <br />N <br />Do-O <br />O <br />CU <br />d. <br />.CM <br />U <br />.� <br />N <br />(�CUC� <br />mo_-�� <br />c <br />O <br />- <br />L <br />N <br />C <br />O <br />LL <br />c <br />O <br />O <br />�O <br />CU <br />> <br />. <br />� <br />ate+ <br />Q <br />L` <br />- <br />c <br />Q <br />C/) <br />CU <br />-*=NJ <br />(3D <br />i <br />U) <br />O <br />_ <br />0- <br />0_ <br />O <br />♦--' <br />O0 <br />O <br />L <br />cn <br />CU <br />�J <br />CIO <br />En <br />z <br />z <br />J <br />a <br />SHEET NO. <br />WP1 <br />s <br />