My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36060 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36060 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 9:57:40 PM
Creation date
2/19/2025 9:57:36 AM
Metadata
Fields
Template:
Building Plans
Street #
36060
Location
Stable Wilk Ave
Contractor
Lennar Homes
Building Plans - Permit #
18616
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />ELECTRICAL DETAIL: <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />DINING ROOM <br />4'-4" 61 W ., L 4'-6" <br />REF <br />1'-11" <br />Fl�_(L <br />---- <br />• <br />\/ <br />DISP <br />KITCHEN <br />FOR <br />HOOD -� <br />6'-11" <br />-F <br />/ F - <br />r- <br />LIVING <br />ROOM <br />I <br />1 2'-3" <br />GFI <br />GFI <br />IJ <br />A <br />�� <br />I <br />�PWDR <br />N <br />HW <br />GFI <br />GFI 1 BATH <br />N <br />' <br />---�- <br />LIGHT AND <br />SWITCH IN <br />-� <br />-' <br />ATTIC <br />- <br />- - - <br />LINE OF� <br />FLOOR I <br />�-ELEC <br />ABV <br />PANEL <br />En <br />1A - <br />; <br />TWO CAR GARAGE <br />/ <br />GFI <br />/ <br />48 <br />I <br />110V CLG GFI <br />N <br />2ND <br />FOYER <br />GFI <br />MNT. <br />OUTLET i <br />FL R ELEC) <br />i <br />i <br />i <br />\ <br />0 <br />i <br />b <br />i <br />4'-0" <br />! <br />C <br />� <br />GFI o <br />WP <br />ENTRY <br />LINE OF <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /411 = 1'-0„ <br />LINE OF ROOF <br />PM r)%A/ <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /411 = 1'-011 <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA NATIONAL FIRE ALARM CODE. CHAPTER 43 2002 EDITION <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING <br />ROOMS, PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON <br />AN A.F.C.I. PROTECT CIRCUIT PER 2008 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2008 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A)BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />[EL7ECTRICALPECIFICATION NOTES: <br />ONTRACTOR MUST VERIFY WITH THE <br />NS FOR THE TYPE OF FIXTURE TO BE <br />FIXTURES SHOWN ARE FOR LOCATION <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />DOOR <br />JAMB <br />TRIM <br />BASE <br />TRIM <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />im <br />SWITCH <br />1/2" <br />DUPLEX _ <br />OUTLET <br />?h <br />- <br />0- <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />v� SWITCH AT 36" <br />Cl) 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-{] PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />+ CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />1 NOTE: <br />0 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />® 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />© RECESS CAN OR LED OWNER <br />® 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 — DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />=24= 24" VANITY LIGHTING <br />c 36 == 36" VANITY LIGHTING <br />`48 = 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />4tp DOUBLE FLOOD LIGHT W/ COVERS AND <br />LJ 150W PAR 38 FL <br />❑ INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />Q CEILING MNT SPEAKER <br />0 CHIMES (DELETE W/ INTERCOM) <br />® MASTER STATION <br />Mi-&::] ELEC PANEL <br />R1 VACUM OUTLET AT 12" <br />vmi CEILING RETURN AIR (W/ SIZE) <br />A/C REGISTER <br />TQ THERMOSTAT <br />® SECURITY PAD <br />17"7 ELEC METER <br />E <br />L.W <br />' <br />Q CIO <br />MN <br />4i <br />�� <br />A) <br />W <br />E C <br />O <br />i o <br />2 <br />MIMEo <br />Z) <br />S <br />Q <br />_s <br />�Ln <br />U <br />U <br />w Q:;� <br />W <br />L <br />Oc) E <br />O ri <br />m <br />7C)v_ <br />a <br />_0 <br />0 LLI uS w O I- <br />W WW � � <br />a �� ��zw Z <br />W C7 W 0.O��QOQ�Q LL §VOO�O <br />`_ 0U) 0zo�oomZZ�0 <br />C3 O O J0a>ZYp~ZLL0QO�wa. <br />a. <br />oZ FZ�WQILL zQ <br />ow o D o¢Q a <br />�Q O � ILL <br />w <br />J <br />� <br />Io <br />" <br />0) <br />N <br />" <br />O <br />O <br />N <br />O <br />> <br />Lo <br />O <br />N <br />co <br />(4q <br />a) <br />V <br />O <br />O <br />CNI <br />Z <br />O F— <br />(n O <br />Ch O <br />QWc0LO <br />ILL <br />Q W Q U? <br />a co <br />Cl0 <br />ZUFa— <br />W <br />J O <br />O <br />O <br />d' <br />O a W <br />• z <br />Z <br />U� <br />O� <br />F— <br />z A6 <br />Uj <br />r— LAST PLOT DATE <br />May. 24, 17 <br />Z 0 1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />B <br />
The URL can be used to link to this page
Your browser does not support the video tag.