My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36065 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36065 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:18:22 PM
Creation date
2/19/2025 9:57:59 AM
Metadata
Fields
Template:
Building Plans
Street #
36065
Location
Stable Wilk Ave
Contractor
Lennar Homes
Building Plans - Permit #
18613
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IILI I I I 1 <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />N1 <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O O O <br />5'-0" <br />STUB -OUT FOR O o o LO <br />GAS METER - 0 <br />o � <br />CV <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY"* <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS" <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE v, <br />15132" CDX <br />PLYWOOD OR <br />7/16" OSB <br />IDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+++ <br />+++ <br />+ + <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />++++++++++++++++++ <br />Z++ <br />++++++++ <br />+11111111111111MI <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/el <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x - <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x - + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x - + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x - lumber <br />FILL CELL—N STD. 900 HOOK r— BOND BEAM <br />CD <br />w <br />STD. 90° <br />CONT. #5 HOOK <br />BAR <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />NDATION <br />TOHIGHEST <br />III <br />�1�� <br />BOND BEAM <br />v <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN-��PLYWOOD <br />FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />�i�SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />"_FOR BLOCKING/TJI <br />"--MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />DOUBLE JOIST <br />CONSTRUCTION <br />(Not required if both loaded equally from above) <br />N.T.S. <br />1/8" min. } Small <br />gap 2�' min. <br />Filler blocking i <br />1/8" 9aP <br />+ i <br />� <br />2" max. <br />4 max. Web Stiffener Fastener Schedule <br />- --- � <br />- <br />i Joist Bearing Location <br />Series Depth : End Intermediate <br />— <br />d <br />2-8d -� <br />x 1C <br />BCI 5000s �- <br />_ <br />-- F � 11-7/8"' 2-8d�_ <br />" <br />3-�8d� <br />Clinch nails f <br />when <br />�_ __ 14 2-8d-Sd <br />9-112 _2-8d�__ <br />2-8d <br />P� s ble <br />BC16000s®IF 11-7/8" 2-8d_ <br />I BCI 6500s®,-14� 2-8d I <br />3-8d <br />5-8d <br />1) <br />Support back of web during nailing to prevent damage to <br />✓ V <br />- - - -t 16" <br />7/g°" j 2-gd - <br />3 8d <br />web -flange connection. <br />, = <br />- BCI 60s® _14 2-8d <br />5-8d <br />2) <br />Block solid between joists for full length of span. <br />Tight fit _ <br />16" 2 8d <br />6-8d <br />3) <br />Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />ytv <br />2x4/PI ood/OSB web stiffener <br />111 7/8" !i 3-16d <br />2" min. ® 5-18 <br />3-16d- - <br />5-16d_ <br />4) <br />Place joists together and nail from each side with 2 rows of 10d nails <br />BCI 90s <br />4" <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or max 16" . 6-16d 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING Ya" GAP @ TOP sides by 6". - Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. hi her than 15001b <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking <br />BEARING Use 3" (10d) nails at 6" o.c. <br />Vertical load transfer =1900 pif max along load bearing wall. ' ' 1 Load bearing walls <br />Load bearing wall must stack F' � <br />. oversquash=20 blocks and <br />Non -stacking walls <br />require additional wall or beam below.* <br />consideration. Check 1 <br />local building �1116" <br />code forappropriate <br />details in One 10d box <br />1' <br />areas=20 of high or-20 sinker ' <br />lateral load. nail each side <br />at bearing. <br />/Provide adequate bearing <br />for each lapped joist. <br />Squash block 10d nails SECTION INT. BRG. WALL <br />(2x4 minimum) @ <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />311 <br />DO NOT cut, notch <br />or drill flanges <br />9 <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />• <br />■ <br />■i�a <br />�77!77§ <br />6" A 1YZ ROUND HOLE MAY BE CUT ANYWHERE IN 6" 6" 0 NOT CUT HOLES <br />THE WEB. PROVIDE AT CANTILEVER ROUND IN <br />LARGER HAN 1Y' <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN %' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %' KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />MUGT15 TYP. <br />5/8"a <br />THRU <br />BOLT <br />MUGT15 TYP. <br />GIRDER TRUSS <br />r 2X TOP PLATE <br />2 X B.U.0 <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 /HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) - <br />��; Nail with 10-10d nails. - - <br />Install tight to top flange. <br />SLEEVE THRU STEM <br />Joist hanger SEE PLAN FOR °• a . • <br />FOUNDATION INFO' '• d' <br />STEM FOUNDATION <br />r— GRADE <br />FillNail with I <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />- lid 1/4"-2" gap— - <br />- Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />il y, <br />-0.6 X Joist <br />depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />REINF. SEE PLAN <br />rvk, unmot 4 rv%, <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF <br />SECOND RT16 <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d x1 1/2" NAILS <br />UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />?II�11'i�iiIlii�;ll. <br />—12" BELOW <br />GRADE <br />" CD <br />' <br />4-z 0 <br />J <br />LU <br />Q. <br />19) <br />LLU <br />LU <br />Ln <br />A <br />10 <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />I � I <br />WE <br />C <br />SEE FND.PLN. <br />SIZE &REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />q d Q / <br />a d �I <br />. i a'd d <br />� d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @PIPE <br />PENETRATION PLUMBING LINE <br />d a' .d • d <br />a' 4, da G <br />d d a _ <br />a d. d • <br />a d <br />•o <br />SEE FND. PLN. <br />SIZE & REINF. <br />U <br />
The URL can be used to link to this page
Your browser does not support the video tag.