36065 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36065 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:18:22 PM
Creation date
2/19/2025 9:57:59 AM
Metadata
Fields
Template:
Building Plans
Street #
36065
Location
Stable Wilk Ave
Contractor
Lennar Homes
Building Plans - Permit #
18613
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING -y <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WEATHER <br />✓E BARRIER & <br />IARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN --�, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />8 z <br />SELF -ADHERED FLASHING <br />M <br />0 <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />NEEDED IN CORNERS <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />FLASHING SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />SELF -ADHERED FLASHING ■ SELF -ADHERED FLASHING 090MI"960 <br />FOUNDATION WEEP SCREED <br />DECK JOIST OUTSIDE CORNER <br />0 <br />SCORED <br />RELEASE PAPER <br />�17 <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />0, <br />1O <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm), Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply With AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked asOin each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of comer may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />- 7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />NOT USED ■ , NOT USED m NOT USED ■ SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />_Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />CD <br />_2 <br />Z M <br />- o <br />z(0 <br />z <br />Q <br />J <br />z <br />cr) 0 <br />Q) C <br />q)m <br />w <br />p <br />"U - <br />O w <br />C <br />I- <br />E <br />o <br />,tomco <br />CO <br />v , �- <br />O <br />a <br />�m <br />U <br />LI-I <br />a, M <br />C co <br />M co <br />4f.2 F- E <br />�rz};'� <br />W` <br />m o <br />N <br />YLGo <br />Of0)too0 <br />0 <br />Qrn <br />rn v <br />rnQo <br />A 1 <br />196.V*1 <br />eDC <br />.� rat <br />r <br />N <br />�N_p r�A <br />E8 � cq <br />- <br />oco <br />t7 y °' <br />0 <br />_L�Z <br />in <br />11 <br />z z <br />I%ZLU tZ <br />I. 8 <br />7 E <br />W <br />W 44 u is <br />d a- LLI <br />a <br />W�dC°LL0 <br />Z <br />CA V < CL <br />Z <br />�y aN <br />CD <br />ILzWm� <br />04 <br />Ir- <br />W N a <br />000 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />Z 0 <br />O a0-4 ) I� <br />I> -I to M CDM <br />Q U1 CO Ln <br />Z <br />12 Ln <br />0 n <br />QLJ LL Ln <br />CL <br />M <br />Q� U� C. 00 <br />� <br />a <br />Z <br />WJ CD <br />tF- <br />oZ <br />2 <br />w0 <br />Z Qa <br />f <br />O <br />�owz <br />2 fui <br />ui <br />C'n <br />65 <br />W N <br />m Z <br />Z Z <br />W <br />Z a <br />X <br />T�0 <br />5 <br />D <br />ro <br />M <br />LL <br />0 <br />w3 <br />2:S <br />; <br />U <br />0 <br />(!) <br />_� <br />a <br />W <br />uLu <br />Q LL <br />aR� <br />Q <br />C <br />N <br />�2M-5 <br />g°doa <br /><Qa <br />Q <br />Z <br />N <br />~�fo <br />$°_;EW <br />Z <br />J <br />� <br />c <br />[off� Z o <br />ILX4 <br />� <br />/y� <br />W <br />01 <br />G <br />Q <br />Q <br />Z <br />W~° <br />Q � Z <br />k <br />.--I <br />z <br />a Z <br />z <br />o <br />g <br />= <br />Z <br /><Lu <br />r, <br />.-I <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION No' 10 <br />SHEET NO. <br />WP <br />