Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />71 <br />Lu <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ 4F <br />+ + + + + + + + c <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + +� <br />+ + + + + + + + + + + + + + <br />+ <br />+ 4 <br />F + + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />.0" (TYP.) <br />6'-0" <br />+ <br />6'-0" <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />++ <br />+ <br />+ <br />+ <br />+ ++ + + ++ <br />+++++ <br />+ + + + + + + <br />+ + <br />++ <br />+ + <br />+ + <br />+ + ++ + + + <br />+ <br />++ <br />T-4- <br />+ + + + ++ <br />+ + + + + <br />+ <br />++++ <br />++++++++ <br />+ <br />t7� <br />— 15/32" CDX I <br />PLYWOOD OR <br />7/16" OSB <br />`—RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />314" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood anels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-118" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x — lumber <br />Double 2 x — lumber <br />FILL CELL STD. 90° HOOK BOND BEAM <br />I <br />USP <br />�GIRDER <br />CO <br />MUGT15 TYP. <br />TRUSS <br />EE <br />a STD. 90° El CONT. #5 <br />CONT. #5 HOOK BAR <br />BAR <br />2X TOP PLATE <br />5/8"0 <br />THRU <br />BOLT <br />BOLT <br />f—r <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />----- <br />���� <br />(1�� BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" min. <br />2" max. 4 max. <br />7-71 <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to 77 <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2"max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or <br />OF THE JOIST ASA REQUIRED LEAVING y" GAP TOP sides b 6". - Hangers with side nailing. <br />@ Y -Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls over squash=20 blocks and <br />require additional wall or beam below <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />lateral load. nail each side <br />10'-0" at bearing. <br />TANK -LESS W/H <br />H C G <br />O O O <br />5'-0" C <br />STUB -OUT FOR O o o Fn <br />GAS METER <br />(V = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4)16d TOENAILS <br />2" X4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block / <br />(2x4 minimum) —/ <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap <br />a' / <br />i <br />4 <br />Boise Joist Blocking <br />Ilse 3" M Qd) nails at 6" o.c. <br />Provide adequate bearing <br />for each lapped joist. <br />10dnails SECTION @ INT. BRIG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series De th End Intermediate <br />® <br />BCI 5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />I 6-16d <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pif max. along bearing wall <br />Required on interior walls: - for vertical load transfer F <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Jo <br />FWhen joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />CD ❑ CD <br />6,A 1�" ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE, <br />7. %' ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />J0 <br />2 X B.U.0 <br />MUGT15 TYP. <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />MIN, EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) I I Ian 117 I I r <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM d ° ' <br />SEE PLAN FOR ' °• • . • ', a . • <br />FOUNDATION INFO <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gaP <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%? gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />Pvt., %,nrAo� 1+ rvw <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF <br />SECOND RT16 <br />° <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d x1 1/2" NAILS <br />UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />PLUMBING LINE <br />TOP (2) #5's x 4' -0" <br />CENETERED @ PIPE PVC OR SCH40 SLEEVE <br />PENETRATION <br />d a ° . <br />d a c <br />�-- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' 0" <br />CENETERED @ PIPE <br />PENETRATION <br />q 4 <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />Q /L� 41.. <br />a •4 : ,4 _ <br />4 <br />SEE FND. PLN. <br />SIZE &REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />C, ° 44 G <br />I= ° 4 c <br />.a <br />SEE FND. PLN. <br />SIZE & REINF. <br />UILO <br />z Cl) <br />— o <br />z <br />J <br />cn <br />4--J <br />�w <br />_ I) <br />"U — <br />LL, <br />O <br />Of <br />r�Lnr ZD <br />I— <br />o <br />M <br />v / h <br />_O <br />p <br />U <br />m <br />w <br />h E <br />CD <br />C' MM <br />am <br />N <br />— O <br />is <br />Om <br />OOD <br />u- <br />= �� <br />U4) <br />L✓ y <br />Sao <br />Lo V <br />Q rn <br />Q <br />rn �L O <br />A <br />8 <br />1 <br />Do <br />N C a D C <br />CO 4a <br />y� > .. <br />CO <br />:. �o� <br />� � a J <br />0� <br />m'�. <br />o <br />�° <br />WSalo <br />� <br />o <br />� <br />0m <br />❑❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z cV <br />0 N N <br />�-A a-' O <br />� ro M O <br />Q U-) � Ln <br />� � 0 <br />Q � U_ <br />1q) z CL �M <br />Q fu <br />clC U <br />C °° <br />a <br />Z <br />WJ C:) <br />d- <br />0 <br />=Z <br />K p <br />z 4a <br />Z2E <br />�17 <br />U�o� <br />Zv0 <br />Z <br />z <br />�o�z <br />0 J <br />0.01, <br />W <br />OV�ceN <br />cc <br />8 <br />LLJ <br />ZZ <br />Q <br />T� <br />z <br />�Z <br />g <br />t-1 <br />0 <br />7O <br />Z <br />43 <br />fu <br />JjF <br />0 <br />> <br />rl <br />0 <br />a <br />U <br />_ <br />�. <br />U <br />J <br />Lu <br />O 0 <br />goo <br />�6� <br />' <br />®` <br />ooc� <br />tV <br />Au,�! <br />Z5108 <br />0 J <br />Q Q <br />Q <br />� <br />s~$onfij <br />z <br />N <br />Wo,2 <br />w <br />Q <br />Eta <br />k <br />O� <br />Q <br />z <br />Z <br />¢�° <br />aZ <br />ca 0 <br />�' <br />S <br />= <br />J O <br />¢ <br />r-, <br />,-I <br />D_ <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />SIN 1 <br />