My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36077 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36077 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:39:53 PM
Creation date
2/19/2025 9:58:15 AM
Metadata
Fields
Template:
Building Plans
Street #
36077
Location
Stable Wilk Ave
Contractor
Lennar Homes
Building Plans - Permit #
18614
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />(� RESISITIVE <br />1 BARRIER <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL - <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - <br />WEATHER <br />JE BARRIER & <br />IARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WEATHER <br />RESISITIVE <br />BARRIER <br />ED FLASHING <br />SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />SEAL TOPS OF JOK <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />DOOR ROUGH OPENING <br />3/4"-l" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB 8 HEAD <br />THRESHOLD Of DOOR AND RETURN FLASHING, SEE <br />UP JAMB 6". USE LIQUID NAIL BRAND SEE DETAIL WINDOW W 0 <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />NAILING FLANGE us <br />Do NOT FLASH OVER 2 SEAL TOPS OF JOISTS <br />BOTTOM NAILING p UNDER DECKING <br />FLANGE o (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />HALF ROUND WINDOW ' EXTERIOR DOOR WITH DECK <br />NOT USED <br />r�.nanuvv r�n.�� uw.a <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />M <br />O <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />NOT USED <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />8 2 <br />0 <br />0 <br />0 <br />0 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF <br />NEEDED IN CORNERS <br />THROUGH SELF -ADHERED <br />FLASHING --� <br />RUBBERIZED RUBBERIZED ASPHALT <br />ASPHALT ADHESIVE ADHESIVE <br />r- SELF -ADHERED FLASHING--, F_ <br />0 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />FOUNDATION WEEP SCREED <br />NOT USED <br />O <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />FLASHING REQUIREMENTS <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />s2 PRODUCTS DETAILS <br />5 TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />4 ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />6 Detail Instructions <br />Refer to the number marked as #�in each detail that corresponds to the numbered items in the list of <br />7 <br />instructions below: <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />Z o <br />13 <br />Z � <br />Z <br />Q <br />Z <br />V) UI <br />Q) u� <br />Q)M <br />w <br />a <br />U - <br />O w <br />Vi �✓ <br />'@ <br />I- <br />E <br />0 <br />0 0 <br />U <br />w <br />N co <br />O) <br />)-- E <br />-8 <br />g <br />m ..c- 0co <br />000 <br />4; <br />a) <br />U0 <br />= a: c0 <br />Cc co <br />0)) <br />�Y <br />moo <br />IO Oft' <br />Q rn <br />M < 6 <br />A IXC <br />N C BB D•C <br />N <br />N U11 cs7 <br />V y 0000' p <br />Z 2E ao <br />a U) o <br />W LL <br />W v C LL N <br />10 W tia'Q� <br />LU <br />CL <br />�� z <br />�Hvw- <br />�soLL <br />�mm <br />N <br />M 0 P� <br />Z 2 Bm- <br />a' <br />W 01 04 <br />N�co <br />J a <br />LLJ O <br />El El ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1! <br />0 <br />0 <br />ZN <br />O a) N <br />4-J o <br />> � M O <br />M <br />Q -a I.r) <br />rCL rZ <br />I- <br />Q �u_� <br />V fl- <br />I-- , M <br />\_7 pt t j m ,--I <br />a E 00 <br />ZrCi <br />WJ o0 <br />d- <br />Z <br />�o <br />�o <br />za <br />z8o <br />Za2i Cg <br />p w <br />InLH <br />R J <br />OY811:1) Lo <br />J <br />W.N <br />m Z <br />Oox <br />Z Z <br />>a , o <br />�- <br />LU <br />C, <br />g <br />*--10 <br />Z <br />LL <br />I� <br />O <br />o <br />a <br />0 <br />2: <br />57 <br />L <br />N <br />Qa <br />J <br />cc <br />o <br />-.., <br />H <br />Q <br />QOQo <br />XOts <br />Q <br />Rm� <br />a <br />N <br />o. <br />¢p¢ <br />OLu <br />oC <br />�¢¢� <br />aW�o <br />Q <br />d <br />Z <br />W <br />N <br />V) <br />age <br />Z,L. <br />� <br />Z <br />o oZ <br />LU <br />Z <br />a a z <br />V� <br />Z <br />T <br />z <br />Z <br />rn <br />r� <br />' ` <br />ui <br />rl <br />Ln <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION N0. <br />2nO <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.