Laserfiche WebLink
NOTES: <br />ELECTRICAL DETAIL: <br />WP <br />GFI <br />1 <br />3 / <br />i <br />FAMILY <br />ROOM co <br />/ F <br />' F / <br />/ 6'-7" <br />6-5.1 <br />MASTER <br />SUITE l <br />w <br />GFI FOR <br />00 <br />HOOD -1 <br />GFI KITCHEN <br />JI <br />TO is <br />MASTER GFI <br />BATH'GFI <br />GFI✓ _' °I DINING <br />REF I i - i ROOM <br />�r DW -- / <br />4.0� T-0" T-8" <br />I GFI �4\ <br />I W.I.C. GFI 3 <br />I � <br />dbi <br />2'-3" GFI <br />UTILITY ANTRY (7_i') <br />A I GFI <br />3)I D A L--+A A <br />PWDR <br />BATH I <br />S-7" 2'-4" N co <br />GFI --- LINE OF \- <br />HW <br />............... � � ��.n <br />LIGHT AND FLOOR �J- <br />J ATTIC :ABOVE <br />SWITCH IN _ <br />ELEC - <br />METER-- <br />ELEC .........__..._ -------- <br />PANEL /=e TO2ND <br />FLR ELEC <br />110V CLG 48 _ <br />oMNT. 1 <br />OUTLET N; � --- --- <br />GFI GFI GFI FOYER \ <br />I I - - I � 3 <br />a <br />I I I <br />wP _ <br />GFI ENTR <br />i - <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE <br />INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />2011 NFPA 70 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER 2011 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2011 2%52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A)BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />TYPICAL 150-200 AMP ELECTF <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />[CAL RISER DIAGRAM <br />NTS <br />LD <br />W_ <br />= W <br />~U <br />w <br />F <br />INTERCOM SPEAKER <br />z <br />a <br />ALIGNED W/ EDGE <br />= <br />N <br />OF SWITCH <br />n o <br />WZO <br />I- <br />N <br />w 00-1 <br />2UO <br />Ow <br />c: <br />w z LL <br />_ J <br />r <br />" <br />u7 <br />ODO <br />2IM <br />Lo <br />io <br />- C:)*k <br />o v W <br />SWITCH <br />Q <br />DOOR <br />JAMB <br />O w <br />z <br />yr <br />} <br />ur Z) ❑ <br />w W <br />3'F.. <br />�..+$ <br />3 <br />' <br />L <br />O <br />w � C1 <br />G <br />�> <br />y_. , <br />r" ,. <br />.O <br />41/2' <br />w <br />UpF-U <br />r <br />o <br />DUPLEX _ <br />Q W C7 <br />TRIM <br />OUTLET <br />ih <br />w � �- o <br />F <br />oQp <br />cn <br />w <br />o <br />W � -� <br />w <br />= In M:1 <br />H I=- <br />Q <br />BASE <br />° - <br />• <br />TRIM <br />o <br />NOTE: <br />(Aj 0 ,^�. <br />o <br />ALL DIMENSIONS ARE FROM <br />L' Q M <br />U <br />ROUGH <br />FRAMING <br />i, } M M <br />N V -0 70� <br />M <br />p <br />O <br />2 <br />o <br />ELECTRICAL LEGEND: <br />61 <br />.�* <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />U <br />� N <br />E <br />N <br />110V DUPLEX OUTLET AT 12 <br />L. <br />a <br />M <br />a <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />CiIio <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />0 w w C w � O o <br />If <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />W W <br />w o a a s ¢ Y z o z <br />< O R o) w " ❑ " mo o <br />s STRUCTURED WIRE OUTLET <br />C) <br />Q Q - <br />I_ <br />-j w o O <br />� O zwu._zm_jo a- <br />�O OWOOm <br />� W a � v� w w � i-n � � Q O❑ � <br />6- SWITCH AT 36" <br />U) OL Z <br />_jan-OWY❑ZZ OW o <br />aoww <br />o~� QQz�a❑a <br />a a <br />69 3 WAY SWITCH AT 36" <br />u_ O I- w <br />-ei*- 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />— DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />A} CLG MNT LT FIXTURE <br />�B CLG MNT PREWIRE - FIXTURE BY OWNER <br />�C} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />O, 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />RECESS CAN OR LED OWNER <br />®' 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL W <br />CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />@s SMOKE DETECTOR <br />-U-18- UNDER CABINET 18" <br />-S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP CO <br />D-48 DOUBLE 48" FLUOR STRIP o <br />N <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />N <br />48 48"CLG MNT WRAPPED FLUOR LIGHT 4 <br />O <br />24 :=� 24" VANITY LIGHTING <br />36 36" VANITY LIGHTING ' o <br />48 48" VANITY LIGHTING O <br />O EXHAUST FAN/LIGHT <br />® EXHAUST FAN LO <br />DOUBLE FLOOD LIGHT W/ COVERS AND ' O <br />150W PAR 38 FL <br />0 INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER ^, <br />® CHIMES (DELETE W/ INTERCOM) V>/ <br />® MASTER STATION <br />® ELEC PANEL <br />FVI VACUM OUTLET AT 12" �+ <br />A CEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />OT THERMOSTAT <br />® SECURITY PAD W <br />En ELEC METER O Q <br />z <br />z <br />ELECTRICAL SPECIFICATION NOTES: -se <br />Q <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE U Ja <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE O <br />USED. LIGHT FIXTURES SHOWN ARE FOR LOCATION <br />PURPOSESAb <br />V <br />0 LAST PLOT DATE <br />Dec. 21, 16 <br />1 ST & 2ND FLOOR <br />0 ELECTRICAL PLAN <br />J� B <br />0 <br />O <br />CNI <br />Z w <br />O I- <br />_> n o <br />0 � M O <br />Q�MLO <br />J <br />6) LL IT <br /><w<LO <br />W 0- M <br />Q Q 00 <br />V <br />Z F- <br />W <br />J O <br />IT <br />z z <br />0 <br />W (1)Ww�_> <br />UH- <br />Q <br />U:) <br />Eo <br />_J <br />�o_-a <br />H <br />0 <br />w � Q <br />w~< <br />LL <br />~0Z <br />co <br />I- = z <br />Q <br />r= <br />v <br />O J <br />Z <br />rn <br />V <br />�2ZW <br />2 <br />(lD <br />` 0 <br />0 <br />O <br />< - <br />0— w <br />M <br />U)zZ <br />N <br />�Qo <br />a <br />z <br />z <br />w <br />J <br />O <br />U <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0" <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1'-0" <br />