My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36125 Stable Wilk Ave
Zephyrhills
>
Building Department
>
Building Plans
>
36125 Stable Wilk Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:24:10 AM
Creation date
2/19/2025 9:58:56 AM
Metadata
Fields
Template:
Building Plans
Street #
36125
Location
Stable Wilk Ave
Contractor
Lennar Homes LLC
Building Plans - Permit #
18231
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />ELECTRICAL DETAIL: <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />ELEC <br />METER <br />LINE OF <br />STRUCTURE ABOVE <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /4„ = 1'-0" <br />LINE OF ROOF <br />RGI n\A1 <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /411 = 1'-0" <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />BATHROOM <br />LAUNDRY ROOM <br />EXTERIOR WATERPROOF <br />GARAGE GENERAL PURPOSE <br />RANGE <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BEAT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL <br />WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY THE <br />NFPA NATIONAL FIRE ALARM CODE. CHAPTER 43 2002 EDITION <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING <br />ROOMS, PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON <br />AN A.F.C.I. PROTECT CIRCUIT PER 2008 NEC. <br />7. IN ALL AREA SPECIFIED IN NEC 2008 210.52, ALL 125 VOLT, 15 <br />AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT <br />RECEPTACLES. <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER N.E.C. 210.8 <br />A)BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE <br />LEVEL NOT INTENDED AS HABITABLE ROOMS AND <br />LIMITED TO STORAGE AREAS, WORK AREAS, AND <br />AREAS OF SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP <br />SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPACLES ARE INSTALLED WITHIN 6 FEET <br />OF THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED IN LIVING <br />ROOMS, DINING ROOMS, SUNROOMS, FAMILY ROOMS, <br />DENS, LIBRARIES, SLEEPING ROOMS, PARLORS AND <br />SIMILAR ROOMS OR AREAS AS SPECIFIED PER N.E.C. <br />210.12 <br />3. ANY CONFLICTS BETWEEN LOCATION OF MECHANICAL <br />FIXTURES ON PLANS AND THE ABILITY TO LOCATE THEM <br />IN THE FIELD MUST BE REPORTED TO THE ARCHITECT <br />PRIOR TO INSTALLATION. <br />[EL7ECTRICALPECIFICATION NOTES: <br />ONTRACTOR MUST VERIFY WITH THE <br />NS FOR THE TYPE OF FIXTURE TO BE <br />FIXTURES SHOWN ARE FOR LOCATION <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />1 <br />200 <br />00 AMP <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />10- <br />#10-3 copper to Dryer <br />METER <br />2/0 or <br />4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />Ll <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />JAMB <br />TRIM <br />BASE <br />TRIM <br />INTERCOM SPEAKER <br />ALIGNED W/ EDGE <br />OF SWITCH <br />SWITCH <br />112" <br />DUPLEX <br />OUTLET (? <br />ih <br />p <br />O <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />ROUGH FRAMING <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />6 SWITCH AT 36" <br />w 3 WAY SWITCH AT 36" <br />-64-2 4 WAY SWITCH AT 36" <br />-O PUSH BUTTON FOR GARAGE DOOR OPENER <br />-0 DIMMER SWITCH AT 36" <br />-0 PUSH-BUTTON DOORBELL <br />A CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />-(Tr)- WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />0 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />RECESS CAN OR LED OWNER <br />Q 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />Q SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />= D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />F-124 7�! 24" VANITY LIGHTING <br />FF=- 36 � 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />O EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />U 15OW PAR 38 FL <br />0 INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />CHIMES (DELETE W/ INTERCOM) <br />® MASTER STATION <br />ELEC PANEL <br />FRI VACUM OUTLET AT 12" <br />CEILING RETURN AIR (W/ SIZE) <br />® A/C REGISTER <br />QT THERMOSTAT <br />® SECURITY PAD <br />ELEC METER <br />N J <br />a <br />=WF: <br />~UZ <br />w< <br />waw <br />w°UU <br />w z m <br />Qw <br />m � <br />0 <br />��N <br />={-z <br />O <br />F= <br />w = w <br />jy Ow 2 <br />w o F- <br />UZLO <br />m a <br />w Z F- <br />w I=- <br />=o� <br />w <br />w <br />F- <br />u- <br />a <br />2 <br />Ow <br />2J <br />N w <br />�0) <br />z. <br />0 <br />N <br />N <br />N <br />0 <br />O <br />0 <br />LO <br />F <br />z <br />d Loloci U <br />ccv) N <br />O^ d n <br />ac <br />m <br />0 s o <br />o <br />0 LL 0 Q <br />w Q� <br />w F M <br />O iD 7 <br />0 LLI uj w O F- <br />LIJ W wF---Q i�� wg, Z <br />(D w afD— U)0�13 [<'002 0 <br />Q � C308�UzoOf lroomo <br />Cl O _j0CL Zy0E-zLL0 0�a <br />G7 0 Z QO W °2��-�IA620 < <br />OE o 5 OQM <br />,L a o FLL <br />- <br />C <br />Q <br />W <br />J <br />0 <br />N <br />N <br />�— <br />N <br />4 <br />O <br />O <br />N <br />O <br />L. <br />N <br />� <br />Lo <br />O <br />N <br />� <br />N <br />L <br />.> <br />v, <br />T� <br />O <br />O <br />N <br />O�- <br />(n O <br />0 F- cM O <br />Q(nC'' <br />ILL � <br />M <br />Q U Q O <br />z I— <br />W <br />J O <br />O <br />O <br />IT <br />z <br />�W 0a <br />J <br />O Q 00 V D- <br />Z <br />ry se Z <br />0 vg <br />0 <br />z A6 <br />Uj CD <br />(V LAST PLOT DATE <br />Dec. 21, 16 <br />z 0 1ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />B <br />z <br />w <br />tY <br />W <br />F- <br />F- <br />O <br />F- <br />w <br />z <br />z <br />Q <br />z <br />a <br />¢ <br />z <br />Z <br />w <br />J <br />d' <br />O <br />O <br />U <br />
The URL can be used to link to this page
Your browser does not support the video tag.