My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36355 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36355 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:52:04 AM
Creation date
2/19/2025 9:59:59 AM
Metadata
Fields
Template:
Building Plans
Street #
36355
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6699
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
42" KNEE WALL WITH <br />1x8 CAP & CASING OR <br />- <br />36" RAILING - <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />3/4" PLYWOOD <br />DECKING <br />_16 <br />r <br />14 <br />,13 <br />Zf <br />PRE-ENG FLOOR <br />12 <br />TRUSS <br />11 <br />1x TREAD (TYP.) 10 <br />I <br />3/4" PLYWOOD <br />Ma I 8 <br />DECKING <br />;0 <br />2x4 THRUST <br />1x RISERS (TYP.) / 7 <br />BLOCK <br />___, _.- <br />2x6 LANDING <br />00 <br />(3) 2x12 `r / <br />2x4 FRAMING <br />5 <br />STRINGERS n 42" KNEE WALL WITH-----( 5 <br />1x8 CAP & CASING OR 4 <br />3/4" PLYWOOD 36" RAILING 3 <br />DECKING <br />2x6 LANDING 2 <br />M <br />g OCKRUST <br />1 <br />2x4 FRAMING <br />TYP. STAIR SECTION <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />than 34 inches and not more than 38 inches. Handrails for Stairways shall be continuous for the full length of the flight, from a <br />point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />returned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />11/2 inches between the wall and the handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />inches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />inches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />sphere 4 inches in diameter. <br />nder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />kith 1/2-inch gypsum board. <br />) SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1: <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 01 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS 1 <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />tiN <br />CONT. HANDRAIL <br />RETURN TO <br />*VVL Ut I HIL <br />SC�ALE- NTS <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS -\ <br />J <br />U <br />w = <br />_O <br />C7 = <br />2"13: <br />z <br />SOY <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />rn <br />fn <br />Lu <br />o D2 N w <br />`r A <br />H10 <br />'l <br />�J <br />TYP. @ 2 <br />STORY. SEE <br />JJ/S6 FOR <br />STEMWALL <br />OPT. <br />(Do <br />6 1/2 33 SH <br />D2 TEMP <br />BEDROOM 2 <br />8'-0" FLAT CLG <br />CARPET <br />-1 " 1. 6-7" <br />1 <br />Ql H1 <br />D2 <br />6 <br />TYP. @ <br />D2 <br />(2) 25-SH <br />CORNERS <br />EGRESS <br />iNn <br />,024 <br />o <br />� <br />24 <br />M <br />3 <br />D2 <br />o <br />G.T.SIM. <br />w/ (1) <br />q <br />MSTAM36 <br />_ <br />@ BASE <br />5068 II 2668 <br />B.F. <br />, <br />'01 1 OWNER'S <br />ME <br />I <br />10, E I - E I I <br />4'-8" 4" <br />4068 <br />mi B.F. <br />------------ <br />R/SH <br />7-6" <br />42" H 1/2 WALL <br />OR RAILING PER 1 <br />SPECS___4 <br />112 <br />TECH 1 11 <br />CENTER I 10 <br />T-3" 1 9 <br />6 <br />188 <br />f <br />_---J 7 <br />D2 <br />BEDROOM 3 4-SH 111002 <br />SIM. w/ (1) <br />8'-0" FLAT CLG <br />MSTAM36 <br />CARPET I <br />---- - - <br />G.T. <br />-------- <br />@ BASE <br />11'-6"--4" <br />11'-2" <br />----- <br />G.T_ - - --- <br />- 00 o <br />Sim. w/(1) <br />= I <br />MSTAM36 <br />c7 I <br />� m <br />- <br />@ BASE <br />BEDROOM 4 <br />3 <br />I <br />I <br />8'-0" FLAT CLG <br />D2 <br />I� G.T.00 <br />I <br />I <br />CARPET <br />1/2 33 SH m <br />I <br />I D2 <br />I <br />I <br />I <br />M I <br />I <br />I <br />L---------- <br />9 25-SH <br />EGRESS <br />D2 <br />B H1 <br />25-SH <br />9 EGRES <br />22 D2 O H1 <br />D1 <br />2'-10" Z-10" 2'-11" 13'-6" <br />C� O" ills All <br />25'-0" <br />I I <br />I I <br />I I <br />I I <br />i I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -i <br />o4 <br />1 <br />L1 <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />3 <br />D2 <br />SIM. w/ (1) <br />MSTAM36 <br />@ BASE <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 92 SYP W/ 1/2" <br />FLITCH PLATE <br />3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />[<H <br />FLITCH PLATE <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />Uq <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />�D <br />+28.3 / -37.0 <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />GG <br />SEE SN SHEET �H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. cMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X252 <br />S.H. <br />13 <br />20X383 <br />181X37d <br />S.H. <br />14 <br />20X50$ <br />181X50 <br />S.H. <br />15 <br />20 X 63 <br />18 2 X 621 <br />S.H. <br />16 <br />20X72 <br />18'X71z <br />S.H. <br />1112 <br />271/4X26 <br />26X252 <br />S.H. <br />11-13 <br />271/4X38g <br />26x373 <br />S.H. <br />1 H4 <br />27 4 X 50 $ <br />26 x 50 <br />S.H. <br />1 H5 <br />27 4 X 63 <br />26 X 62 112 <br />S.H. <br />11-16 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J4 X 26 <br />36 2 X 25 1/2 <br />S. H. <br />23 <br />37 Ja X 38 s <br />36 2 X 37 3/4 <br />S.H. <br />24 <br />374X505 <br />362X50 <br />S.H. <br />25 <br />37 a X 63 <br />36 2 X 62 1/2 <br />S.H. <br />26 <br />37 'X 72 <br />36 2 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 2 X 251 <br />S.H. <br />33 <br />54 X 38 s <br />52 2 X 37 a <br />S.H. <br />34 <br />54 X 50 8' <br />52 2 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 2 X 62 2 <br />S.H. <br />36 <br />54 X 72 <br />52 2 X 71 z <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence &Attics -Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA 952 S.F. <br />SECOND FLOOR LIVING AREA 1121 S.F. <br />TOTAL LIVING AREA 2073 S.F. <br />GARAGE 396 S.F. <br />LANAI 104 S.F. <br />ENTRY 32 S.F. <br />TOTAL SQ. FT. 2605 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - ELEV-13 <br />SCALE: Y4'=V-0" <br />e� <br />CV <br />C <br />cv <br />9 W <br />CD <br />O CD <br />C,4 <br />LL. d <br />v o <br />tN CV <br />w c d <br />'> o s <br />Co O <br />ro 3 �: cc <br />i N C G <br />H S -0 <br />c E <br />o <br />®. v <br />.10 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />.1 W�4 <br />t' z <br />a <br />v E <br />O M 0 <br />o <br />O N6 10 r <br />g� <br />Q <br />00 N_ <br />oo t <br />¢k <br />(i <br />U) u� <br />H [t' ik lJi <br />C <br />�+ <br />(� <br />J LL <br />1 w a <br />.<WR <br />Z <br />a <br />L <br />VA <br />W <br />= N r (O O <br />2 <br />in Oj <br />J <br />LO CO Z Q <br />N J <br />Z <br />O U U O <br />o0 <br />N M <br />RN <br />Q <br />J <br />N <br />N <br />Q) <br />� a <br />C9 0 <br />+-, <br />CC$ <br />U <br />w <br />-� <br />O <br />N <br />w o <br />c r <br />ys <br />U c <br />W J <br />r. <br />I <br />4� <br />S L <br />6 N <br />o <br />My <br />J <br />a <br />Z <br />w <br />z <br />LL � <br />E <br />� O <br />E G7 <br />wo <br />of <br />w= <br />>N <br />v <br />0z,© <br />0" <br />cu rO <br />o <br />0 <br />2� <br />&a <br />60 <br />wg <br />00 <br />o< <br />�Z <br />�w <br />U:> L <br />a C <br />m J <br />¢ z <br />p U <br />"� <br />m O <br />O, <br />z r <br />aw <br />° <br />�z <br />go <br />� 3 <br />m <br />0a < <br />� <br />w <br />a Z <br />Nw <br />w <br />o <br />< <br />w <br />GIs <br />�o <br />cy <br />d' <br />zl¢ <br />2F <br />0 3 <br />N <br />>M <br />m <br />0 <br />CO Cfl <br />O <br />=3 r <br />C0 <br />>N <br />T_ <br />V / U <br />4-0 <br />y J <br />j CIO0 <br />>L <br />O <br />N <br />LO <br />N <br />Q <br />'- <br />/CO <br />W <br />6 <br />m <br />y' TT <br />� V <br />co\ <br />iii Lf) <br />a <br />Z <br />Z <br />E <br />n <br />E <br />U � <br />¢ p <br />� <br />� <br />JOB <br />NO: <br />23-06103 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />TT-r m r <br />
The URL can be used to link to this page
Your browser does not support the video tag.