36358 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36358 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:04:35 AM
Creation date
2/19/2025 10:00:21 AM
Metadata
Fields
Template:
Building Plans
Street #
36358
Location
Garden Wall Way
Contractor
Lennar
Building Plans - Permit #
6078
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />SCORED 12 <br />V" <br />STUCCO 5 <br />BANDS <br />T.O.P. <br />--- <br />EXTERIOR <br />PLASTER <br />r� ON FRAME <br />co F- <br />SCORED <br />STUCCO \J <br />BANDS <br />25 SH <br />2nd FIN. <br />-- <br />FLR.--- <br />-- —�� — — --o <br />T.O.M. <br />SCORED <br />STUCCO <br />\ /-- BANDS <br />CJ / WEEP <br />HDR. HGT.— <br />0 <br />71:::11 F17 M 7E: 1 EEl <br />TEXTURED <br />U <br />1 /� <br />U <br />CEMENTITIOUS <br />FINISH ON CMU <br />El El El El El Ell El E] <br />c9 <br />SCORED <br />STUCCO <br />ElBANDS 171ElElE]1711� <br />sk <br />FIN_FLR_N <br />n n n n <br />t--� r--��--tl---t — — — — <br />I.-FLR.— <br />T_O.M._ <br />------------------ ---- <br />T.O.M. GAR. _ <br />ENTRY <br />HDR. HGT. <br />SCORED <br />STUCCO <br />BANDS <br />16070 OVERHEAD DOOR <br />12 <br />�5 <br />FLASHING <br />12 <br />FRONT ELEVATION - B <br />SCALE: 1/4" = V-0" <br />-- W T---- <br />SCORED <br />STUCCO <br />BANDS <br />C14 <br />C1r <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS 1 <br />®ice - -- - _ - <br />SCORED <br />STUCCO <br />BANDS <br />r, <br />SILL DETAIL <br />SCALE: 3/4" = V-0" <br />SCORED <br />STUCCO <br />BANDS <br />HEAD DETAIL <br />SCALE: 3/4" = V-0" <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ------ <br />— <br />— FLASHING- <br />--- ---------------------- <br />--------------------------------------------------------- <br />CJ / WEEP <br />35 SH <br />FIN. FLR. _ _ t — — — ---------------L-1--------t-------------------------------------------------------------------------t-- <br />RIGHT ELEVATION - B. <br />SCALE: 1/4" = V-9' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"A" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall b continuous to the to f <br />e m e e u po <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09,24.21 <br />aTMa <br />c <br />C <br />LU <br />go"M <br />C14 <br />s <br />ra <br />rQ <br />.ems- CV <br />exZ:L�� <br />Er-� <br />CJ <br />� E <br />zZ u <br />Ro <br />�O <br />ul <br />FLO <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H <br />W <br />g <br />E <br />V <br />7 ^ <br />$ <br />N N N r <br />°W. Co N W <br />Co US <br />0 <br />7 o c0 # <br />a6rNiv <br />C <br />LL d <br />,n <br />Z <br />0 <br />-J Lu <br />(0 C13 0 <br />�_ <br />W= <br />MN (O Y <br />W <br />Z <br />0 . <br />coL0 NZ d � <br />Z <br />N O <br />C) V <br />W <br />E311 <br />z N M <br />� o <br />z <br />z o <br />J <br />rz <br />z <br />�-14-1 <br />'J <br />w <br />—� <br />O <br />�N <br />W0 <br />0 <br />N <br />U <br />LIJ <br />J <br />s <br />— � 8 <br />= w <br />¢ <br />N <br />I� <br />d <br />J <br />w <br />Z <br />M <br />Z 0 <br />o <br />Z <br />� <br />i <br />za <br />gZ <br />>M <br />QN <br />n- p <br />E U <br />oLL <br />Lj <br />z® <br />o a <br />1 @ <br />xo <br />=O <br />U <br />Gd0 M <br />b¢ <br />0< <br />¢0 <br />aZ <br />o <br />ao <br />� <br />m0 <br />Z <br />m J <br />mm <br />¢w <br />Uo¢ <br />Z� <br />Z <br />gaO <br />W <br />Cq <br />T <br />CDQO <br />w 2 <br />N F <br />M <br />w F <br />a 0 <br />00 <br />>Milli <br />0 <br />L <br />T� <br />.-. <br />O <br />Cr <br />co <br />O <br />(n m <br />N <br />LO <br />N M <br />O <br />0CY)LO <br />00 O <br />I {') <br />N <br />r <br />E <br />r <br />M <br />o <br />Z <br />m <br />z <br />E O <br />N r <br />d <br />E <br />U J <br />Q 0 <br />J <br />JOB <br />NO: <br />23-00506 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />2.1 <br />