ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A <br />INDOOR <br />PANELCENTER <br />10 #14 to lights & outlets <br />NEMA i 00 #12 to appliances and GFI <br />150AMPl <br />200 AMP 10 #10to WH <br />00 #8 to Range <br />00 #a t0 HVAC <br />MO <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17.250.94 <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be. 16 AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />De <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />0 <br />TELEVISION (OPTIONAL) <br />N 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />i <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED ' <br />RECEPTACLE FOR <br />MICROWAVE RANC <br />HOOD PER SPECS <br />1.5" VTR _Ifl 3" VTR <br />I� <br />111 I <br />I� I <br />I I <br />I � I <br />1113" VTR <br />R <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />/ --- <br />--. <br />W <br />�Il <br />Gil <br />1 <br />l <br />GFI <br />I <br />/ <br />u- <br />xCI <br />N <br />C <br />GFII <br />I <br />FG <br />i <br />IL <br />I <br />ITCHEN N. <br />REF <br />FOR <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />A/C PAD <br />DISC. WIP <br />GFI <br />DEDICATED------' <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />0� fr <br />w w <br />l- p <br />WZJ <br />�O� <br />m <br />�UI=— <br />j0 <br />FlM \4—DB & GFI TO <br />------- ' BE ALIGNED <br />VERTICALLY <br />I <br />a! <br />COACH LIGHTS ACOACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / PER SPECS <br />FIRST FLOOR ELECTRICAL—B <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I ---------------------------------------- <br />SECOND FLOOR ELECTRICAL-13 <br />4\� <br />c� <br />QL <br />a> o <br />w <br />ct s <br />L3 o <br />C -!b N <br />M x <br />U- <br />N l4 Q <br />av t~ <br />zra; d d <br />aT tv � <br />a E <br />� v ' <br />_ C' <br />N d� <br />E <br /><v � <br />o. w <br />`o <br />m <br />0 <br />CV <br />N_ <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0) <br />W <br />g <br />v E <br />0 <br />C <br />ii <br />0 <br />LQNl <br />aN 6 m r <br />-- <br />C, w <br />5 ,n m <br />cn I- r-- <br />M V 2S2S LL <br />LL <br />W <br />� 5 a <br />J U <br />� <br />Z <br />roc°' d ai <br />0X`�$ <br />W <br />_ <br />O N O <br />rn�N m <br />W <br />Z <br />IL <br />W <br />y <br />M Z Q <br />ZN <br />,IL <br />OU <br />W <br />❑❑ <br />a <br />V M !P <br />Z N t") <br />0 0 <br />z C, �Q <br />Z o <br />a <br />J — <br />� LL7 <br />� <br />— N <br />M <br />z <br />_ o <br />w <br />� <br />U <br />0 <br />o <br />,„cli <br />LLJ <br />J <br />E <br />l <br />l <br />8 <br />`r - <br />U 0 N <br />CO <br />to <br />N <br />o <br />C�J <br />M <br />Z <br />w <br />Z <br />Q <br />L3 <br />Z <br />N <br />Q p <br />E: Vca <br />I— 1.6 <br />Z <br />0 <br />o a <br />_ <br />� E <br />�¢Cn <br />-< <br />a= <br />� <br />Z <br />wZ <br />�W <br />in <br />z< <br />�� <br />oLL <br />2 <br />Z <br />m <br />s <br />U <br />O m <br />Q W <br />ZZ <br />0 <br />g0 <br />oLL <br />dZ <br />0 w <br />W <br />O <br />m <br />rcg <br /><0 <br />S� <br />�W <br />Z <br />' <br />o <br />w <br />0 <br />;o <br />IIIIIIIIIII' <br />V <br />0 <0U <br />E <br />c5 <br />�CD <br />'M <br />J <br />O <br />�• <br />rn <br />� <br />V <br />CID <br />00—�. <br />0 <br />aa. <br />(n m <br />N <br />4-1 <br />L0 <br />7 <br />CU M <br />CD <br />~ <br />.Q <br />SZ <br />o <br />00 <br />Ln <br />N <br />M N <br />�— <br />N <br />.T• <br />i� <br />T <br />M ` <br />o <br />Z <br />Z <br />E 0 <br />Ui r <br />rn <br />c`a <br />c <br />E <br />d) <br /><Q <br />n <br />0 -° <br />p <br />JOB <br />NO: <br />23-00506 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />