Laserfiche WebLink
(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />1/2" MINIMUM CEMENT FINISH <br />(2) 2x HEADER TO SIT <br />2x6 / 2x8 WALL BEYOND FLUSH TO THE OUTSIDE STANDARD 3" DIA. TEE <br />SEE PLAN FOR HEADER SEE PLAN FOR SIZE THREADED 3" DIA. EXTENSION <br />CONNECTION SCREW OFF CAP (3" DIA.) <br />2x DEAD WOOD @ MID FOR CLEAN -OUT <br />POINT w/ (3) 12d MIN. EXTENSION FROM <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />7 5/8" 8" 7 5/8" 8" <br />I <br />❑ SOLID AREAS ARE ❑ <br />7 5/8" 8" <br />DOUBLE 2x TOP TONEAILS SPACED EXTERIOR FACE OF BLOCK ❑ STEEL AND GROUT ❑ ❑ <br />PLATE EVENLY WALL IS 1 1/2" MAXIMUM <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />12 <br />SEE ELEV. <br />INTERIOR FULL 8x8x16 BLOCK SIMPSON SP2 w/ 12 10d / \I <br />HEADER FLUSH TO OUTSIDE OPTION EXTENSION FROM EXTERIOR WALL ❑ ❑ ❑ NAILS AT EACH STUD �V <br />FACE OF BLOCK WALL IS 21/4" <br />2x BLOCKING @ EACH END W/ 10d @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />2x BOTTOM PLATE W/ (1)10d @ 8" <br />VARIES O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL <br />SCALE: N.T.S. S4 <br />12 <br />SEE TYPICAL WALL SECTION <br />(TYP) SEE ELEV. <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2) 12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />SIMPSON SP2 w/ (12) 10d <br />(3) 10d TOENAILS T&B <br />NAILS AT EACH STUD <br />AS REQ'D <br />2x BLOCKING @ MID <br />+ <br />POINT EVERY OTHER <br />STUD W/ (3) 10d NAILS <br />CRICKET AS REQUIRED ---\ <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />1/2" EXTERIOR GRADE SHEATHING ' <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)1UL <br />0d <br />NAILS AT EACH STUD <br />2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/ 8" EMBEDMENT <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />AND FILLED SOLID W/GROUT <br />1 #5 VERT. IN CONC. FILLED CELL W/ <br />STD. 90^ HOOK IN K.O. BLOCK <br />KNEE WALL ABOVE MASONRY WALL DETAIL <br />MOUNTING BASE NOT SHOWN <br />FOR CLARITY SEE DETAIL <br />K/S4 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />GENERALNOTES <br />SLOPE FORWARD <br />FOR DRAINAGE <br />BLOCKING (TYP.) <br />PROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE <br />SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM <br />C. 926 APPLY 3 LAYERS W/ <br />TOTAL THICKNESS 7/8" OVER <br />METAL LATH. FIRST 2 LAYERS <br />3/8" THICK EACH. 3RD LAYER <br />1/8" THICK OVER WATER <br />RESISTIVE BARRIER <br />Ct DOOR OPENING DOOR OPENING DOOR OPENING rt 1/2" EXTERIOR GRADE SHEATHING CRICKET AS <br />TO DRAIN FASTENED TO TRUSSES WITH 8d REQUIRED <br />EXTERIOR ❑ ❑ a COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" BLOCKING ( ) <br />WALL CLEAN -OUT A WALL ❑ ❑ ❑ 0/C FIELD <br />SCALE: N.T.S. S4 ❑ ❑ 2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />1ST COURSE 2ND COURSE 3RD COURSE CARRIER/GIRDER TRUSS <br />REFER TO WINDOW PRODUCT APPROVAL MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COURSE MUST BE BONDED TO THE NAILS OT EA. TRUSS VERTICAL/WEB <br />SHEETS FOR INSTALLATION INFORMATION BY COURSE BELOW. EVERY THIRD (3RD) COURSE THE 11" DOOR JAMB WALL IS TO BE (24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />MANUFACTURER. WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. IN KO BLOCK AT EA. STUD <br />MAIN SPAN <br />TYPICAL SECTION THRU WINDOW B MASONRY LAYOUT D MOISTURE BARRIER ROOF TRUSS <br />UPLIFT CONNECTOR <br />S4 SCALE: N.T.S. S4 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. (SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT <br />4 ° a <br />I <br />g" STD.90`HOOK 8" <br />LINTEL BEAM W/ (1) #5 CONT. IN OPENINGS <br />GREATER THAN 6-0" WIDE (U.N.O. ON <br />PLAN) <br />OPENING <br />FILLED CELL W/ (1) #5 VERTICAL <br />SEE FDN. PLAN FOR LOCATION <br />NOTES: <br />1O FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PR(QVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />Q SEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO U-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" <br />FORM CONCRETE INSET TO <br />1/2"X9 1/2" PLYWOOD CREATE A SOLID BASE FOR <br />SCRAP MATERIAL BLOCK WALL ABOVE. <br />J <br />J <br />Q <br />w <br />T > <br />0 <br />FORM CREATES CONCRETE RECESS TO <br />2X4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />MOUNTING BASE SHOWN <br />IN POSITION GARAGE ENTRY FORM DETAIL <br />i 2x6 MOUNTING BASE <br />8x8x16 C.M.U. GARAGE DOOR <br />C— <br />C GARAGE DOOR ROLLER <br />CONNECTION ASSEMBLY <br />.., GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B) <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />TRACK MOUNTING BRACKET <br />GARAGE DOOR TRACK <br />SCALE: N.T.S. <br />96 3/8" <br />88" <br />71" <br />58" <br />41" <br />34' <br />10" <br />31/2"- <br />00 <br />2x CRIPPLES @ <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w/ (6) <br />10d x 1 1/2" AT EA <br />STUD (USE SP6 FOR <br />2x6 WALL, USE SP8 <br />FOR 2x8 WALL) <br />10d NAILS @ 8" <br />OIC TYP. <br />DOUBLE 2x <br />CRIPPLE STUD <br />TYPICAL (U.N.O.) <br />1 #5 VERT. IN CONC. FILLED CELL <br />W/ STD. 90° HOOK IN K.O. BLOCK— i- <br />VERTICAL JAM ALT. KNEEWALL ABOVE MASONRY WALL DETAIL <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71 ", AND 96-3/8"ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. SCALE: N.T.S. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />NOT TRANSFER LOAD. <br />2x6P. <br />J-BOLT <br />TRACK <br />BRACKET <br />uvvn i nr,r� <br />W/MOUNTING ANGLE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. <br />TYPICAL GARAGE DOOR BUCK K <br />SCALE: N.T.S. S4 <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2 x 4 WALL <br />2 x 6 WALL <br />STRAPS <br />SIZE <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1' - 4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1) LSTA30 <br />4'- 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />GREATER HEADER <br />(2) 2x HEADER SEE PLAN <br />• INTERIOR HEADER: <br />S4 (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />BOX HEADER . EXTERIOR HEADERS: <br />ONLY (1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />• OPENING LARGER THAN 4 FT: <br />(2) 2x SILL PLATE w/ SIMPSON <br />LS30 w/ (6) 10d x 1 1/2" EACH <br />SIDE <br />' 2x STUDS TYP. <br />00 SIMPSON HTT4 TYP. <br />Op O,Q U.N.O. SEE N/S4 <br />NQ1,** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL Q <br />SCALE: N.T.S. S4 <br />SIMPSON SIMPSON <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />PIPE OR DUCT w/ PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE - NAILS TOTAL) EA. SIDE OF <br />\� SPLICE STAGGERED <br />011 �� <br />ATTACH ALL J <br />EXTERIOR STUDS <br />W/ IAI 16d TOENAILS <br />TO Y6P PLATE <br />NOTE: <br />PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TOP PLATE SPLICE DETAIL rM <br />SCALE: N.T.S. S4 <br />F= 2240 LBS <br />SIMPSON C <br />SIMPSON SP4 SP2 <br />P.T. <br />ATE <br />TRANSOM FRAMING <br />SEE SECTION J/SS <br />AND K/SS FOR <br />ADDITIONAL DETAILS <br />RECESS <br />LINTEL <br />SIMPSON SIMPSON <br />SP4 SP2 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP1 SIMPSON <br />SIMPSON SP4 <br />SP4 <br />INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />SP4 <br />SIMPSON <br />SP1 <br />SIMPSC <br />SP4 <br />TRUSS BOTTOM CHORD OR 2x4 <br />W/ 2-16d TOE NAILS <br />'BLOCKING <br />@ EACH END <br />w <br />v <br />v? a <br />r g `n <br />2x TOP PLATE <br />2-16d NAILS @ 24" O.C. OR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2x STUD @ 24" <br />O.C. MAX. <br />PROVIDE P.A.F. NAILS OR <br />2x P.T. PLATE <br />EQUAL @ 12" O.C. <br />STAGGERED FROM BOT. <br />SEE AIS3 FOR <br />PLATE TO CONCRETE <br />REINF. INFO. <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL <br />SIMPSON SP4 <br />�2X TOP PLATE <br />OVERLAPPING <br />--10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />2X8 P.T. BOTTOM P ATE p <br />5/811x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />SCALE: N.T.S. S4 <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />SPF) <br />(3075# SPF) <br />i (4565# SPF) <br />i (5645# SPF) <br />i (6970# SPF) <br />IS (9335# SPF) <br />N. 8" <br />'OXIED A.T.R. <br />t & NUT <br />'OXIED A.T.R. <br />t & NUT <br />DXIED A.T.R. <br />t&NUT <br />ROOF TRUSS ABOVE <br />/— 2X BLOCKING <br />�(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />• <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" D.C. <br />C <br />MASONRY WALL <br />SIMPSON C <br />SP4 <br />10d NAILS @ 4" 10d NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" L PLYWOOD <br />O/C BOUNDARIES 6" O/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6) 10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2X8 WALL) SHEATHING <br />• SIMPSON SP2 w/ (12) 10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10) 10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />2X8 P.T. BOTTOM <br />PLATE <br />UU <br />5/8"x10" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY <br />REV. 06.24.22 <br />SCALE: N.T.S. <br />c%Q <br />0 <br />' <br />... > <br />0 <br />v ¢r <br />e <br />�o <br />N "G9 CV <br />� N N <br />E C <br />„O_ <br />� 3 <br />C _® <br />H � � <br />= E <br />v <br />" I I#9" <br />1aI._ e, <br />�%$ <br />...,.. <br />, <br />w-�. <br />kp ¢ G <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />to <br />w IE <br />O � O N U <br />v (D oCco <br />0 <br />a) <br />O 7 'i N <br />r 0 <br />co <br />0 <br />.M.// Qj M 't <br />C <br />u' <br />� <br />La <br />�i -j <br />J�i� <br />W <br />Z —ern <br />=ca <br />o <br />y „o <br />W = N ~ <br />°o <br />U 5 <br />,Z 10 N 0 <br />co <br />Q J <br />04 <br />Z O0 <br />_ <br />U cn <br />w ❑ O <br />❑ � M � <br />z N M <br />o g <br />N <br />z o � <br />� <br />M <br />VAz <br />O o-a) <br />t/1 <br />w. <br />J <br />z,, •.. <br />= <br />8In <br />V O N <br />M <br />C <br />N <br />.4 Id <br />ti <br />o <br />Jz <br />w <br />c <br />M <br />M <br />J <br />ZO <br />Q <br />`2 <br />4 <br />6 E <br />� 0 <br />E U <br />wo <br />-o <br />sLL <br />wz <br />>� <br />Q� <br />zp <br />oa <br />. CU <br />ro <br />a <br />Mg <br />w� <br />0o <br />p E <br />¢r <br />n <br />0< <br />� <br />ao <br />pQ <br />wz <br />�w <br />Cf:� <br />a0 <br />¢z <br /><0, <br />mO <br />m <br />J <br />N m <br />4 W <br />1 <br />c�i <br />z <br />¢o <br />CIOdU <br />p > <br />tt � <br />z <br />s <br />r1 <br />m <br /><0 <br />w <br />� <br />o <br /><Q <br />;o <br />V <br />O <br />o- <br />¢ <br />U <br />S 0 <br />o C <br />_ <br />CU <br />T <br />CU <br />(D <br />i <br />T <br />Q <br />M <br />N <br />m <br />LO <br />� <br />}+ <br />0 <br />0 <br />-0 <br />M <br />n N <br />t— <br />TT <br />Q ce) <br />m <br />:tfm T cM T <br />r � LO <br />o <br />z <br />Z <br />E T— 2 <br />`m <br />a <br />E .. 'a_ <br />U _j Q 0 <br />1 <br />JOB <br />NO : 23-06106 <br />SCALE : AS NOTED <br />SHEET NO. <br />S4 <br />17 -_HT r I -- — _ _r__�r r <br />