My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36371 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36371 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:08:29 AM
Creation date
2/19/2025 10:00:44 AM
Metadata
Fields
Template:
Building Plans
Street #
36371
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6681
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />-------------------------------I <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONY. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 1 Od x <br />1 1/2" NAILS EACH <br />1W <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />1 CHORD AT ALL HAND FRAMED AREAS TYP. <br />A <br />DIRECTION TYP. <br />Z—WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />EXTEND <br />FOUNDATION PLAN <br />SLAB 1 1/2" <br />->�`--*= <br />.. 4i <br />(2) #5's CONT. T&B w/ <br />-' 4" <br />#3 STIRRUPS AT 4'-O" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />1'-4" <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />1 Od TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"0.C. MAX. w/ (3) 1Od <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT-/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a@, INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2' <br />•. <br />a_ <br />4" <br />z <br />PORCH SLAB SEE <br />a <br />N <br />FOUNDATION PLAN <br />w I <br />(2) #5's CONT. T&B <br />.. . <br />z <br />w/ #3 STIRRUPS AT <br />N z <br />4'-0" WHEN DEPTH <br />T <br />EXCEEDS 30" <br />LOWER OR <br />sk <br />GARAGE SLAB <br />1'4' <br />SEE PLAN <br />LARGE <br />STEP <br />DOWN <br />17 <br />SCALE: N.T.S. <br />SCALE: N.T.S <br />3 <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />SEE ROOF <br />PLAN SHE <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A —A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />USSES <br />(2) 12D NAILS <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />HIP <br />G.T <br />WOOD POST. SEE FLR <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />EXTEND <br />SLAB 1 1/2" <br />41` <br />- (2) #5's CONT. T&B w/ <br />- 477 <br />#3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE 7 WHEN DEPTH <br />FOUNDATION PLAN - EXCEEDS 30" <br />-- GRADE <br />n• I -ram <br />- -I <br />V-4" <br />2 ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />INTEGRATE MASONRY ABOVE MASONRY <br />KNEEWALL INTO CMU BASE OR PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF PLAN FOR COLUMN <br />REQUIRED INFO <br />MASONRY KNEE WALL MAX 3 <br />COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 <br />z <br />0 <br />Q <br />W <br />J <br />W <br />W <br />W <br />W <br />W/ (1) #5 CON <br />REQ'D @ MID <br />I <br />II <br />r <br />I II <br />I I <br />I <br />I <br />I <br />I <br />I � <br />I <br />T. FILLED CELL VERTICAL EACH <br />SPAN MAX 6'-8" CORNER FILLED <br />MAX 3 SOLID. SEE ELEV. <br />Ak COURSE FOR BASE SIZE <br />(3) #5's EA. WAY <br />- -x ° x-= <br />It <br />9LAB <br />"- <br />PORCH EE <br />SLAB S S <br />LEVEL FOUNDATION PLAN <br />2 #5' CONT T&B / - - <br />SEE CUT #3 STIRRUPS AT 4'-0" - '- <br />CONTRACTOR TO INSTALL ( s w - • N <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" <br />1'-4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL �16 <br />SCALE: N.T.S. <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHEF <br />SEE FLOOR PLAN <br />FOR COLUMN SIZI <br />& ADDITIONAL INF( <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BILK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />SIMPSON HUC410 w/ (14) <br />� � � <br />SEE PLAN <br />FOR CANT. <br />16d INTO HEADER & (6) <br />10d INTO BEAM - SEE <br />ROOF PLAN FOR MORE <br />INFO <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE <br />7116" OSB FLITCH PLATE <br />CONNECTION INFO <br />_ <br />_ <br />REQ'D ONLY WHEN <br />7/16" OSB FLITCH PLATE <br />�__— <br />SEE FLOOR PLAN FOR <br />INDICATED ON BM. <br />— SCHEDULE/PLAN <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION A SCHEDULDE/ON PLANM <br />OPTION B CONNECTION INFO <br />OPTION C <br />COMMON BM TO POST ATTACHMENT <br />EXTERIOR SHEATHING A <br />ATTACHED PER SEE ROOF PLAN <br />NAILING SCHEDULE FOR BEAM SIZE <br />CONNECTION INFO. <br />1 2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION aC� FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A � A <br />SEE PLAN FOR <br />TOP OFgEAM <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALLr7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 1 Od <br />1F 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE. 1/2 - 1-0 <br />%2" CDX PLYWOOD OR %6" O.S.B. <br />SHEATHING REQ'D FROM BOTTOM <br />OF WALL TO ROOF SHEATHING <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES <br />SEE PLAN MAX. <br />24" STEPS <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />a 4.4. d. <br />N z <br />GARAGE OR r <br />LOWER SLAB <br />SEE PLAN <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />USS/ <br />MIN. (2) 2x8 #2 SYP <br />HEADER. SEE Q/S4 FOR <br />REQ'D CONNECTIONS <br />2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & SPT24 @ <br />TOP <br />2x4 #2 SYP P.T. PLATE W/ <br />V EPDXY ANCHOR OR <br />2 J-BOLT OR X" TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />HKI <br />MIN. 6" EMBEDMENT <br />n' a <br />v v v v _ <br />_4 <br />4 4 <br />d o MAIN HOUSE <br />SLAB <br />a. <br />nJ 4, <br />(2) #5's CONT. T&B <br />a 4 w/ #3 STIRRUPS AT <br />a a 4'-0" WHEN DEPTH <br />EXCEEDS 30" <br />a <br />i <br />�° <br />Le <br />�- i —g <br />1'-4" <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />e•7 <br />0 <br />N <br />o <br />-a <br />L U <br />Q� o <br />C'V <br />y C W G <br />�® <br />y�C <br />E �. <br />a� <br />� E <br />�yd�� d°f <br />Lt S <br />b <br />bib <br />- O <br />E^�� <br />>- <br />�L <br />ra/1aatltE€�c�b4 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specificationscontained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />o W <br />4 <br />,E <br />O N 8 <br />ls. <br />0 <br />a) W 0.1. r <br />W N N <br />_ - <br />a <br />- <br />M <br />Q <br />�rNi�v 3 u� <br />C. - g W w <br />C. W LL 3 � <br />c <br />13 <br />W <br />Y <br />Z <br />m c <br />L co V _ <br />Wi <br />z <br />= NNE <br />Co <br />U) ch Z <br />.' <br />Z <br />J <br />N O U U O <br />W <br />❑❑ <br />O O <br />z <br />z o � <br />r <br />M <br />z <br />�N <br />M <br />W w <br />Vmi <br />O <br />W o <br />�y N <br />.� <br />M <br />7- <br />rJ <br />C <br />W � <br />p <br />z� <br />UUj <br />. <br />00 <br />- <br />Q N 0 <br />ti <br />o <br />J <br />W <br />M <br />M <br />J <br />Z ¢ <br />- <br />z <br />z <br />4 <br />2 <br />E <br />=o <br />>� <br />14 <br />E U <br />oz <br />o° <br />�a <br />�o <br />o E <br />o <br />co C <br />p� <br />az <br />S< <br />a <br />�z <br />Qo <br />m� <br />o, <br />8 <br />Z <br />Cn <br />°LL <br />dz <br />y w <br />A <br />m <br />G 0 <br />O <br />F H <br />o <br />wY <br />;o <br />V <br />O <br />a <br />0 <br />Q <br />U 2i <br />�o <br />= <br />a) <br />� <br />L,n <br />c) <br />6 <br />rn <br />r <br />� <br />CID <br />CD <br />Q <br />CT Y <br />cc <br />m <br />L() <br />1.- <br />0 <br />� <br />) <br />M <br />Ln <br />n N <br />T <br />T <br />Q <br />c <br />m <br />E <br />co T <br />Z <br />r <br />j <br />Z <br />E I— <br />c <br />a <br />U 0 <br />v <br />Q p <br />� <br />JOB <br />NO: <br />23-06106 <br />SCALE: <br />AS NOTED <br />SHEET NO. <br />D1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.