My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36371 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36371 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:08:29 AM
Creation date
2/19/2025 10:00:44 AM
Metadata
Fields
Template:
Building Plans
Street #
36371
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6681
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C11' <br />C> <br />C I <br />Cr <br />V) <br />to <br />C> <br />to <br />C> <br />1 <br />10 <br />X) <br />19 <br />C) <br />E <br />C0 <br />(D <br />E <br />.2 <br />CN <br />C� <br />714 <br />X) <br />.-4 <br />C> <br />V14 <br />15 <br />M <br />M <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />42" KNEE WALL <br />(16) RISERS AT 7 -9/16" <br />WITH 1x8 CAP <br />10" TREADS wl 3/4" NOSI <br />NG1 <br />& CASING <br />USP MP3 CLIP EA. <br />3/4" PLYWOOD <br />STRINGER TO BEAM/ <br />DECKING <br />FLOOR SYSTEM TYP. <br />FLOOR SYSTEM <br />13�, <br />0 <br />12 <br />Oil <br />42" KNEE WALL WITH <br />9 <br />1x8 CAP & CASING <br />STORA E <br />8 B <br />UNDER <br />36" H. CONT. <br />60 <br />STAIRS <br />7 <br />GRASPABLE <br />1xTREAD 61 <br />RAILING <br />(TYP.) <br />1x RISERS 1-1 <br />1x8 CAP & <br />(TYP.) <br />CASING <br />OP 3 <br />2xFRAMED <br />2x FRAMED <br />(3) 2x12 <br />WALL <br />WALL <br />STRINGERS <br />2x4 #2 SYP. P.T. THRUST BLOCK--/ <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />SCALE: 1/4" = V-101" <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handralls with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8,3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />I SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 0 <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENE <br />LANDING FOF <br />STRINGERS 7 <br />CONNECTTC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERALFLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" 0. C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />CONT. HANDRAIL <br />RETURN TO_ <br />*B WALL DETAIL. <br />SCALE: NTS <br />10'-2" 1. T-1 <br />111-0.1 1. 14'-0" <br />9 <br />140C <br />REV 10 1 20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />81-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />91-011 <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9-4', THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0- END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS IS ONLYUSED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS - <br />WINDOW SCHEDULE <br />SIZE <br />R,O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18JX25J <br />S.H. <br />13 <br />20 X 381 <br />184X 371 <br />S.H. <br />14 <br />20 X 501i <br />8 <br />18 J X 50 <br />S. H. <br />15 <br />20 X 63 <br />18 J X 62 J <br />S.H. <br />16 <br />20 X 72 <br />18 JX 71 J <br />S. H. <br />IIH2 <br />27 1/4 X 26 <br />26X254 <br />S. H. <br />1H3 <br />27 1/4 X 381 <br />26 x 37 1 <br />S. H. <br />1H4 <br />27JX50i <br />26 x 50 <br />S.H. <br />1H5 <br />27JX63 <br />26 X 62 1/2 <br />S.H. <br />1H6 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37JX26 <br />364X25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1i <br />8 <br />36 1 X 50 <br />7 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />364X71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73JWIDE <br />S.H. <br />32 <br />54 X 26 <br />52JX254 <br />S.H, <br />33 <br />54 X 38 J <br />52'X374 <br />S.H. <br />34 <br />54 X 501 <br />52 17 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52JX62J <br />S.H. <br />36 <br />54 X 72 <br />521 X 71 <br />7 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br /><e(2) <br />> <br />- 2XIS #2 SYP W/ 1/2" <br />FILITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FILITCH PLATE <br /><@>(2) <br />- 2X 10 #2 SYP W/ 112" <br />FILITCH PLATE <br />(2) - 2X1 2 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 1 3/4" X 11 1/4 LVIL <br />2.OE Fb=2950 <br />(2) - 1 3/4" X 9 1/4" <br />LVIL 2.OE Fb=2950 <br /><e>(2) <br />- 1 3/4" X 16" <br />LVL 2.OE Fb=2950 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.OE Fb=2950 <br />RAG <br />I <br />(2) - 2X4 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />Follow Q/S4. See Plan for <br />Bearing Wall Call Out When <br />Straps are Required <br />VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 -32.2 <br />+29.7 / -39.7 <br />+28.3 -30.8 <br />+28.3 / -37.0 <br />+26.6 -29.1 <br />+26.6 / -33.5 <br />N SHEET SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED IN"DICAtT7T�A�BOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />� +29.7 / -39.7 <br />SECOND FLOOR PLAN - A <br />SCALE: )/4"=1'-0" <br />General Notes <br />R302.5 Dwelling/Garage Open inglPenetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.1 1, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M 1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work.. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALLLEGEND <br />I I I 17-177771 MASONRY HGT. @ 8'-8" A,F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1 ST FLOOR LIVING AREA 721 S.F. <br />2ND FLOOR LIVING AREA 807 S.F. <br />TOTAL 1528 S.F. <br />GARAGE 397 S.F. <br />LANAI 60 S.F. <br />ENTRY 30 S.F. <br />TOTAL SQ. FT. 2015 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-1 1/R-1 3 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE' <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />CIA <br />C2 <br />C� r� C= <br />M C-3 <br />-W <br />C= ca <br />C-4 <br />E <br />CS <br />g <br />Cu <br />CM <br />T <br />y"e- <br />�) <br />C) <br />C <br /><) <br />L <br />"o <br />N�' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineeft signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />W <br />E <br />0 c) 8 <br />ON C� Cb <br />C <br />0 <br />ID N <br />00 w - <br />:3 Lo 10 <br />U) LO <br />It <br />C') .4 *h <br />c: - L� Lu <br />M LL <br />Lu <br />Z <br />C, <br />W <br />;;, 0 <br />W <br />Z <br />IL <br />o, M <br />cc) Z� 0 . <br />< <br />LO co Z <br />< <br />Z <br />E� 0 <br />6 0 < <br />Q U) <br />W <br />00 <br />0 <br />V) <br />LU <br />0 <br />1.71 <br />V) <br />ci <br />a 11,11 Vill <br />E <br />0 US <br />0 ID <br />U) <br />M 0 <br />0 <br />N <br />CD <br />co <br />Cl> <br />Z <br />U- <br />cd, E <br />z <br />z <br />E 8 <br />E <br />@ <br />0 L <br />cu <br />.0 <br />00 <br />Z <br />CD E <br />co <br />WM <br />CO <br />Z <br />1Z <br />0, �'l <br />�z <br />W <br />2 <br />z <br />co <br />< <br />0 <br />w- <br />0 <br />< <br />0 <br />.0 <br />0 <br />L6 <br />0 <br />0) <br />12 <br />CU <br />0 <br />ILO <br />C.0 <br />cc <br />U) 12, <br />3: <br />C\1 <br />0- <br />L0 <br />C) <br />014 <br />C'4 <br />Lr) <br />V) <br />C:) <br />r- C`4 <br />E <br />-E <br />00 <br />L0 <br />0 <br />ca <br />Z <br />:3 <br />E <br />E <br />0 <br />0 <br />< <br />JOB <br />NO: <br />23-06106 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.