ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES. - <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />i 'Rill <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />❑0 <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />MAIN <br />O <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />1 to lights & outlets <br />2 to appliances and GFI <br />D to WH <br />to Range <br />to HVAC <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />III, 1.5" VTR <br />'I <br />I <br />I <br />I <br />� I <br />/ I <br />I I <br />PLUMBING RISER <br />SCALE:NTS <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />TCH FOR DISPOSAL <br />0 <br />3" <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />PER SPECS <br />ELECTRICAL PLANS <br />SCALE: %4'=1'-0" <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />If 11 <br />II ALT II <br />I 1 AC PAD I I <br />it 11 <br />L=====J <br />WP <br />G F I <br />DISC. <br />H <br />wZ <br />20W <br />>_jm <br />o <br />N <br />c <br />7 <br />d LU <br />> W <br />a� <br />c ca c;:' <br />--oCo <br />ILL. <br />N � O <br />U) 'O N <br />f/! O <br />� <br />3 <br />� d <br />�. <br />L C <br />fC <br />E <br />a. <br />N <br />� <br />0 <br />N <br />M <br />L0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and <br />seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's signatureq seal. <br />Band <br />$= o P 1lti. <br />1Y1,1 <br />W <br />E <br />O c) <br />oo 0) <br />� <br />cp p�vi <br />J <br />0 <br />m Q 3 <br />'Zr4 ��LL I <br />LL a a <br />a Y U <br />4' <br />to L.L <br />W Z <br />Z <br />13 <br />Co e °? <br />O <br />cc <br />r M o <br />0 5 <br />0 o <br />m Lu <br />W <br />LL <br />7 t6 N (O <br />0 <br />J Q <br />J Z <br />w <br />< <br />Z <br />o� <br />❑❑❑ <br />W <br />N M <br />o 0 <br />.5 N <br />Q � Q <br />2 � <br />r` <br />LU <br />V <br />O—� <br />N <br />1, o <br />w <br />uva <br />F- .9 <br />U <br />of J <br />— _ E <br />'° UU t <br />o <br />w <br />M <br />M <br />y Q <br />Z <br />Z <br />Q <br />_ <br />L.t_ <br />� E <br />z o <br />�z <br />> M <br />ao <br />of <br />zp <br />N <br />o E <br />Q <br />W K <br />CO <br />L <br />w O <br />oW <br />W Z <br />5 rc <br />CID <br />4 <br />oo <br />01 <br />Z <br />m Q) <br />aw <br />Z <br />go <br />W <br />co <br />oQ <br />1 <br />w <br />a <br />o <br />¢ <br />Q= <br />w� <br />~ ¢ <br />3 _5D <br />;o <br />v <br />0 <br />03 <br />C> <br />o 0O <br />m <br />>L.0 <br />0 <br />ui <br />m <br />`m <br />C� <br />r <br />Q <br />CT T <br />r <br />Com <br />Ln <br />_ <br />LO <br />M <br />> 04 <br />LC) <br />LO <br />n N <br />r <br />r <br />Q <br />at <br />� <br />M M <br />o <br />m <br />T <br />� <br />Z <br />Z <br />E <br />f4 <br />a <br />E <br />o <br />0 _j <br />v m <br />Q o <br />m <br />JOB <br />NO: <br />23-06106 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />�ttT I - - - - - 1 .1 - ri - ,JI �.IP � . ( r-u�. a1.. I�irl'.t � f I -i,r �i '. � .. I I --�� T i- -I 1 i i � — �r <br />