Laserfiche WebLink
_C� <br />LO <br />C:) <br />0 <br />=3 <br />U') <br />C <br />LO <br />C� <br />LO <br />0 <br />C: <br />0 <br />C::1 <br />5�1 <br />0 <br />M_ <br />E <br />E <br />n <br />W <br />LO <br />L0 <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />:.., <br />1) SEALANT AT <br />4) SEALANT JOINT <br />VONDOWBUCKTO <br />OUTSIDE EDGE OF <br />MASONRY <br />WINDOWBUCK <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOWBUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADD NG AND VANDO <br />I <br />FRAME _��V <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06 05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V'SEALANT SOCKET NTH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1. Cut, fold up & temporarily secure, <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />S <br />DO NO' <br />BOTTO <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHING <br />SHEATHING <br />BY LAPPING DOWN <br />OVER RIM JOIST AND UPJ-:� <br />WALL BY 6 IN. <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI,< <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />I <br />%SHING <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING - <br />1 <br />Q <br />2 SEAL TOPS OF JOISTS <br />§8 UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />DOUBLE <br />JOIST <br />SINGLE /F- WOOD BEAM <br />JOIST BELOW <br />. ....... ........ .. .. Z <br />�7ZSINGLE <br />JOIST <br />SELF -ADHERED -ADHERED <br />FLASHING FLASHING <br />SCS 06 02 WINDOW FIN INTERFACE WITH <br />bLL1--AUt1l=KLU FLAbHIN(3 <br />EXTRUDED SHOULDER <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL-­___ <br />PRODUCTS DETAILS <br />TILE FINISH <br />------- <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />1/2" DUROCK-----_ <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as # in each detail that corresponds to the <br />Rinstructions <br />numbered items in the list below: <br />1. Install self -adhered flashing in order as shown by numbers <br />8" CMU <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />4" OR 8" CMU <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) <br />4. Split the release paper using the ripcord (Split release on demand, <br />FILL WITH GROUT <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />SLOPED MUD BED <br />.11 <br />6. Fold as shown by arrows <br />2 <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />VINYL SHOWER PAN <br />8. Mechanically fasten as necessary <br />SLOPE <br />'R <br />Q <br />V-4" PER PLAN <br />V-10" PER PLAN <br />>4 <br />4 <br />4 4 <br />-4 <br />SHOWER SEAT <br />< <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Lu <br />C/) <br />> <br />00 <br />< <br />Z <br />Z Z <br />CL <br />LU Lu <br />U) <br />C/) <br />LU <br />Lu <br />rr <br />I-_ 0� <br />< Lu <br />W i� <br />Cn 0 <br />- A V_ WINDOW UNIT <br />DOOR ROUGH OPENING SLOPE FLASHING REQUIREMENTS <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0. 6 cm : 30.5 cm) include flashing as described in Section R703.4. <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6", USE LIQUID R703. 1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER EXTERIOR <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />PROOF CAULKING CEMT. FIN. of draining to the exterior water that penetrates the exterior cladding. <br />SELF -ADHERED FLASHING BUILDING PAPER <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBIFLOOR other approved water -resistive barrier shall be applied over studs or sheathin <br />of all exterior walls No <br />15 asphalt felt shall be a <br />lied <br />. <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />RIM JOIST No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />IT <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />Q <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />0 1 <br />EMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />RUBBERIZED <br />INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />FLASHING JAMB & HEAD THROUGH SELF -ADHERED R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING SELF -ADHERED FLASHING applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL VVP01) membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE PAPER TO EXPOSE <br />EXTEND A MINIMUM 6' ADHESIVE AS SHOWN) contraction, ASTMC 128 1, AAMA 812, or other approved standard as appropriate for the type of sealant. Flu id -applied membranes used as <br />VERTICALLY FROM <br />THRESHOLD shall be installed at the following locations: <br />BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />1. 1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />2 following: <br />C <br />I NSTALL SELF -ADHERED <br />F LASHI NG JAME, 8, HEAD <br />F LASHING SEE <br />FLAN VIND �W <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br />g I manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />7 subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br /><> <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SELF -ADHERED FLASHING <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />INSIDE CORNER <br />L120 2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />]so <br />stucco copings. <br />3. 3.Under and at the ends of masonry, wood or metal copings and sills. <br />Ground <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />7.7.At built-in autters. <br />Water Resistant Barrier <br />:LF-ADHERED FLASHING <br />TCH <br />HERED FLASHING <br />I4 <br />5 <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE To TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />y 3-1/2" INCH FLANGE <br />- ----- ---- THIS GAP IS A RESULT OF <br />PLASTER STOP <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />::771 <br />CONTINUOUS BACKER <br />ROD & SEALANT DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTI LEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) -0 ------- C_ <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY - <br />SHEATHING, 'OSB*, PLYWOOD, DENSGILASS <br />kSTER STOP <br />NTINUOUS BACKER ROD <br />EALANT <br />MENTITIOUS FINISH <br />FRAMING <br />SHEATHING <br />ANE WRB <br />WRB <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />e ui Ing paper an meta lath must be <br />installed over the top of the weep screed. <br />/`8*N WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1 063 <br />Building Paper <br />7/16" 0. S. B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />Cn <br />CID <br />C.') <br />CU <br />ce> <br />C1,11 <br />C=> <br />C=. <br />To the best of the Engineer's knowledge, informatIon and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />U) <br />Aga 4 <br />E <br />8 <br />oroff-M <br />S-1 <br />0 <br />UJ5 <br />.2 00 � <br />co �w <br />Lu <br />. ... .. <br />3 <br />C: <br />W <br />=.g <br />M CN 0 <br />0 Z, <br />W <br />Z <br />LL <br />(0 <br />co Z <br />a <br />< 0 <br />Z <br />W <br />E3 lu--)] <br />< <br />ul <br />XCD <br />0 <br />0 <br />LU <br />0 <br />V) <br />�] <br />'u <br />= E <br />U 6 61' <br /><c 0 <br />1441- <br />c::, <br />Co <br />0 <br />Z <br />< <br />U_ <br />cz E <br />12 <br />Z 6� <br />C>_ 0 <br />E U <br />CU <br />20 <br />00 <br />CL <br />C,0 E <br />7. <br />" <br />0� <br />C., < <br />Z01� <br />M <br />C, <br />X <br />C: <br />2: C) <br />Z <br />R <br />02 <br />0 <br />W <br />U5 <br />C) <br />Z <br />M <br />8 <br />- <br />MJ <br />C"> <br />Wo <br />'M <br />5? C:) <br />E2 <br />a) <br />> CO <br />_J <br />0 <br />11 <br />CU <br />(3) <br />CD <br />< <br />co <br />U) <br />CN <br />ca <br />LO <br />+- <br />0 <br />C) <br />(3) <br />0 <br />CN <br />a) C:) <br />U') <br />(N <br />< <br />0 N <br />I'll, <br />CD LO <br />E <br />-E <br />0 <br />Z <br />Z <br />E Ir- <br />(n <br />a) <br />E <br />0 0 <br />'0 <br />JOB <br />NO <br />23-06116 <br />SCALE <br />AS NOTED <br />SHEET NO. <br />WP1 <br />