Laserfiche WebLink
r <br />0 <br />v <br />0 <br />a� <br />tZ <br />0 <br />u7 <br />Lo <br />0 <br />0 <br />a <br />N <br />N <br />L0 <br />0 <br />w <br />0 <br />I <br />z <br />Q <br />v <br />Cr) <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />BARRIER <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />DOOR ROUGH OPENING <br />-� __�-- <br />WEATHER <br />SLOPE <br />RESISITIVE <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />BARRIER <br />TAPE EXTERIOR <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING 3/4%1" BEAD OF CONSTR. <br />(0.6 cm: 30.5 cm) <br />include flashing as described In Section R7O3.4. <br />B ,. SHEATHING <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND <br />WALL BY 6 IN. RETURN UP JAMB 6". USE LIQUID <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />(ASSEMBLED WINDOW) <br />2 <br />NAIL BRAND OR EQUAL WEATHER <br />O <br />EXTERIOR <br />CEMT. FIN. <br />water within the wall assembly by providing awater-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />�- <br />PROOF CAULKING <br />O <br />of draining to the exterior water that penetrates the exterior cladding. <br />WEATHER <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />RESISITIVE <br />z BARRIER <br />SEAL TOPS OF JOISTS 1A <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />UNDER DECKING SUBFLOOR <br />(SEE DETAIL WP07) <br />- <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />SELF -ADHERED FLASHING <br />- T- <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />- <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />HEAD FLASHING TIE-IN IaysTRuxel <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />her <br />�. cut, fold ri temporarily securere weather <br />weaat <br />RIM JOIST <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />THESE DETAILS ARE GENERIC AND <br />resistive barrier above header to allow for <br />flashing installation <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />2. Self -adhered flashing plus head flashing under ,� <br />weather resistive barrier <br />,� <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />BE USED. <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />2 <br />2 <br />O <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />Scale: NTS <br />SELF -ADHERED <br />EINDOWING ■ 1 <br />ING■SELF-ADHERE1 <br />FLASHING ■' <br />Exception: Where barrier has <br />EXTERIOR DOOR WRTHDDEGKHSECTION A <br />CEMT. FINISH SILU PO SHEDLF/ CH MNEY SHOULDER <br />the water -resistive that is applied over wood -based sheathing a water resistance <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />EXTERIOR SHEATHING <br />,I <br />3/4"-V BEAD OF CONSTR. INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB &HEAD <br />NEEDED IN CORNERS ADHESIVE <br />ASPHALT ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />3/8" CEMENT <br />PLASTER <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturers instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />12 MIL DRYLOK CMU -MASONRY BLOCK <br />FLANGED WINDOW <br />UP JAMB L USE LIQUID NAIL BRAND (SEE DETAIL WP01) <br />OR EQUAL WEATHER PROOF CAULKING <br />membranes used as flashing <br />g shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />EXTREME <br />REFER TO TECHNICAL <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />WINDOW <br />LETTER ON CHEMICAL Oj <br />COMPATIBILITY <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />FASTENER <br />1) SEALANT AT <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING, <br />_ <br />��° (BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />4) SEALANT JOINT WINDOWBUCKTO <br />° <br />EXTEND A MINIMUM 6" <br />ADHESIVE AS SHOWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the a of sealant. Fluid -applied membranes used as <br />ppp pp <br />OUTSIDE EDGE OF ' MASONRY <br />WINDOW BUCK <br />° <br />VERTICALLY FROM <br />BOTTOM OF <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved fleshings <br />e <br />2)SEALANT JOINT <br />° ° <br />THRESHOLD <br />O <br />shall be installed at the following locations: <br />5) SEALANT FROM INSIDE EDGE OF <br />2 a <br />WINDOW FRAME WINDOW BUCK <br />ACROSS WINDOW BUCK <br />SECTION -A (SEE DETAIL WP02) <br />AND EXTEND TO WINDOW FRAME <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />MASONRY ATTACHED <br />PER CODE <br />N,° ° SELF -ADHERED FLASHING <br />U <br />/ <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with or more of the <br />6) TOOLED SEALANT REQUIREMENTS <br />`/ 2 <br />one <br />BEAD BRIDGING <br />following: <br />CLADDING AND WINDOW <br />FRAME <br />2 <br />SELF -ADHERED FLASHING <br />5 <br />1.1 The fenestration manufacturer's installation and flashing instructions, r for applications not addressed in the fenestration <br />g 0 pp <br />3) SEALANT WINDOW FRAME T <br />WINDOW BUCK ALL THE WAY <br />NAILING FLANGE 1 <br />_ <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />AROUND, INCLUDING SILL. <br />DO NOT FLASH OVER 2 <br />O. <br />SEAL TOPS OF JOISTS <br />DECKING <br />�+ <br />6 <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />BOTTOM NAILING 8 <br />UNDER <br />(SEE DETAIL WP07) 2 <br />7 <br />subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />FLANGEJ <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SCS 06 05 CMU INSTALLATION 6 POINT BUCK AND <br />_ <br />SELF -ADHERED FLASHING ■ <br />I <br />SELF -ADHERED FLASHING ■ <br />I <br />SELF -ADHERED FLASHING ■ ' <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />FENESTRATION INSTALLATION AND INTERFACE <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />SHEATHING <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />= <br />Water Resistant Barrier <br />7.7.At built-in gutters. <br />JAMB, SILL AND HEAD DETAIL <br />Lath <br />APPROVED <br />Sheathing <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />APPROVEDHOUSETHING WRAP <br />PATCHDHEREDFLASHING <br />STRUCTALATH TWIN TRACK 2.5 <br />Stucco <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />3/4"CEMENT PLASTER <br />° <br />c� <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />DOUBLE <br />° ° <br />° ° ° <br />7/8„ Cement Plaster <br />"V' SEALANT SOCKET WITH <br />JOIST <br />° a 4 ° a <br />TOOLED APPROVED SEALANT <br />SINGLE WOOD BEAM <br />° <br />in accordance with 7/8" Cement Plaster <br />JOIST BELOW <br />1 SELF -ADHERED FLASHING <br />Foundation Wall ° ° ° <br />ASTMC926 in accordance with <br />SELF -ADHERED FLASHING <br />° o <br />°ASTMC926 <br />oil <br />2 <br />°° <br />Felt backed metal <br />3" MIN <br />e <br />lathe in accordance Felt backed metal <br />SELF -ADHERED SELF -ADHERED <br />4 <br />with ASTMC1063 lathe in accordance <br />FLASHING FLASHING <br />with ASTMC1063 <br />2 <br />O <br />5 <br />Building Paper <br />�;�� <br />Building Paper <br />7/16" O.S.B. <br />sheathing O.S.B. <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING <br />■ , <br />SELF -ADHERED FLASHING ■ <br />FOUNDATION WEEP SCREED ■ , <br />sheathing <br />; : Metal sheathing <br />EXTRUDED SHOULDER <br />DECK JOIST <br />OUTSIDE CORNER <br />.. Flashing <br />Weep Screed <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL <br />- - - - - r1 <br />- �� <br />Installed As Per <br />Manufact. Specs. <br />PRODUCTS DETAILS <br />TILE FINISH- <br />I� STRIP OF SAF LEGEND <br />I 1 SELF ADHERED FLASHING (SAF) <br />Maintain Stampede or similar <br />Bottom of �cauk bottom <br />F- <br />DRAINAGE PLANE WRB DRAINAGE PLANE (DP) WEATHER RESISTANT <br />I <br />Weep Screed joint only <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />112" DUROCK <br />Lu <br />j <br />I BARRIER (WRB) - - - - - - - <br />I - - _ <br />Il BOND BREAK WRB BOND BREAK WEATHER RESISTANT BARRIER- <br />SELF FURRING (SF) LATH <br />1 1/2" to 2" <br />Above Roof Weep Screed <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />¢ <br />h PLASTER ACCESSORY <br />'OSB', <br />Sheathing Installed As Per <br />I _ SF LATH SHEATHING, PLYWOOD, DENSGLASS ® <br />Manufact. Specs. <br />V-4" PER PLAN <br />z <br />I <br />Detail Instructions <br />1'-0" PER PLAN <br />j I j WRAP DP WRB ONTO <br />I- THE VERTICAL <br />„ <br />1/2 Cementitious <br />Refer to the number marked as I ## in each detail that corresponds to the <br />I 1 SURFACE TO TOP OF <br />Cement Plaster Decorative Finish <br />numbered items in the list of instructions below: <br />I: FLANGE AS AN AIR <br />in accordance <br />I II BARRIER <br />I <br />with ASTMC926 � ®,. All inside and <br />1. Install self -adhered flashing in order as shown by numbers <br />F-- ----- <br />8" CMU SLOPE <br />I <br />I I-u2" INCH FLANGE <br />®•o•• . ®® .°®®° <br />over wood 2nd •®°®° outside corner will <br />floor <br />2. Install flashing and weather resistive barrier to form water shedding <br />-�- <br />J I <br />®®•®®®,® need to be miter <br />laps <br />Q ° a <br />4"OR8" CMU ° <br />_ - <br />----------------- <br />___--------------- ll I <br />° cut and caulked all <br />3. Self -adhered flashing can be substituted for building paper <br />AT DEPTH) <br />(PER ) H <br />z <br />z <br />1 <br />I STRUCTURAL FRAMING <br />'`®•o.° ®•: buttjoints need to <br />° ®,° o ®•. <br />4. Split the release paper using the ripcord (Split release on demand <br />p p p g p ( p <br />' <br />FILL WITH GROUT I� a <br />g <br />g <br />a <br />i <br />_" �,d ;i <br />� <br />' ° ®°®,° ® •®°• becaulked using <br />®i ° ° <br />embedded in the adhesive layer) - for ease of installation and to <br />- STRUCTURAL SHEATHING <br />Stampede or sim. <br />minimize scoring cuts <br />a ° ° <br />d <br />a- <br />THIS GAP IS A RESULT OF <br />PLASTER STOP NATURAL SHRINKAGE. STRIP OF SAF <br />caulk for all <br />5. Remove all release paper per standard installation instructions and <br />° <br />2 <br />U) <br />- - - - - - - - - DO NOT SEAL. <br />CONTINUOUS BACKER --- ---- ---- DRAINAGE PLANE WRB <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />U <br />ROD & SEALANT DRIP SCREED PLASTIC ; I <br />Minimum) <br />° <br />SLOPED MUD BED ° <br />LLJ <br />_ <br />LU <br />ACCESSORY I I BOND BREAK WRB <br />I I <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />8 ° ° <br />° <br />H <br />Cl) <br />w <br />o <br />i SF LATH <br />fit flight to <br />Q <br />VINYL SHOWER PAN 11 <br />I <br />corner <br />a ° <br />N ° ° d <br />() <br />I <br />8. Mechanically fasten as necessary <br />° <br />-J ll <br />---------- ; --------`------- ; ; <br />SLOPE ° <br />- <br />I <br />The building paper and metal lath must be <br />Cement installed over the top of the weep screed. <br />PLASTER STOP <br />Plaster <br />a <br />A <br />US BACKER ROD <br />over block <br />a <br />4 Q <br />a <br />& SEALNAUN <br />1 st floor <br />CEMENTITIOUS FINISH <br />WEEP SCREED DETAIL <br />SHOWER SEAT ■ <br />SOFFIT/CANTILEVER ■ , <br />SCALE: NOT TO SCALE <br />012 <br />N <br />O <br />N <br />ucs <br />o <br />- <br />> W <br />C C- <br />C 'R CJ M <br />m <br />C >C <br />y R O <br />&* <br />N O 1p <br />= =Q <br />� <br />3 � <br />u � <br />=E <br />Cl- <br />0 <br />CV <br />LO <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />QpN <br />v EE <br />V <br />N a, o <br />� � C N r• <br />fid <br />Q <br />N O ik <br />M LLL � w <br />a <br />� <br />m c 0,1 CO <br />y@moo <br />W <br />0 <br />ILaNm <br />Z <br />Do 0 m w <br />�, M Z a � <br />Z <br />w' <br />N O U 0 <br />W <br />❑❑ <br />V M <br />N <br />N c7 <br />O O <br />Z <br />N <br />Z o 6d <br />� <br />Q <br />J <br />ca- <br />N <br />N <br />Z v <br />v <br />4-1 <br />FEa <br />O <br />U <br />W o <br />U <br />W J <br />E <br />U o <br />m <br />c rn <br />o <br />Z <br />w <br />Q0 <br />J <br />o,Z <br />, <br />Z <br />� <br />W <br />o <br />z o <br />Z o <br />o- <br />m V <br />oz <br />0® <br />oa <br />H rp <br />0. <br />Ma <br />?0 <br />E <br />az <br />°Z <br />co <br />t <br />ao <br />¢z <br />dZ <br />Wz <br />Ui <br />¢z <br />a°z <br />m0 <br />Z <br />C <br />m J <br />xQ <br />Z <br />MW <br />� m <br />Zz <br />Z <br />v� <br />T <br />ap <br />LL <br /><Z <br />R Z <br />N <br />W <br />CM0 <br />¢ o <br />o� <br />r <br />�3 <br />CID <br />w <br />zl¢ <br />0 3 <br />Lo <br />J <br />O <br />d" <br />is <br />c� <br />CM <br />Co Lr) <br />r <br />LO <br />DJ.. <br />(n <br />N <br />.2- <br />rQ <br />Ln <br />a� <br />zCIO <br />M \ <br />Lf7 <br />o <br />z <br />E 1- <br />c <br />a <br />E <br />U 0 <br />Q ig <br />° <br />JOB <br />NO: <br />23-06109 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />