My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36461 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36461 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 12:19:35 PM
Creation date
2/19/2025 10:02:14 AM
Metadata
Fields
Template:
Building Plans
Street #
36461
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6597
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYP. @ <br />CORNERS <br />1 <br />D2 <br />TYP. @ A <br />LOW ROOF <br />yVS` U <br />CJ2G I I CJ2G <br />I I qD <br />I I <br />CJ4G CJ4G <br />2A1 _ <br />GL1 <br />2rh— <br />—ff— <br />TO <br />——�— — <br />I — — <br />— — <br />J <br />ILL <br />II <br />ILI <br />— <br />77 <br />— <br />II <br />I -I- —y-- r— — <br />— — <br />23 <br />— <br />II <br />LL— <br />II <br />II <br />— <br />J— <br />S6 <br />TYP. <br />I I <br />UM. <br />I I <br />— <br />I —T — <br />— — <br />TYP <br />FL2 <br />_ <br />_ <br />— <br />N <br />All <br />FL9, <br />I <br />R <br />FL9 <br />II <br />II <br />A <br />I <br />/ <br />�2) <br />LLi. <br />n <br />n <br />(2) <br />A <br />r 1 <br />S5 <br />SIM. @ <br />CONNECTIONS <br />TYP. <br />U.N.O. A <br />TYP. @ A <br />SINGLE S3 <br />STORY <br />00 <br />J <br />LL <br />RSH <br />AND <br />ENCLADD MEAN <br />CLADDING W NDFPRESSURES ANDOSUUCTIONIS FOR ROOFOHEIGHT <T5ft <br />WIND SPEED (ULTIMATE) <br />140.0 MPH <br />WIND SPEED (ALLOWABLE) <br />108.4 MPH <br />EXPOSURE CATEGORY <br />C <br />EFFECTIVE <br />WIND PRESSURE AND SUCTION (PSF) <br />HIP <br />ROOF >20 TO45 DEG. <br />WIND AREA <br />(+) VALUE DENOTES PRESSURE <br />a=oft <br />(SQ FEET) <br />(-) VALUE DENOTES SUCTION <br />[4:121-[12:12] <br />AREA <br />ROOF <br />1 <br />2e <br />2n <br />2r <br />3 <br />3e <br />3r <br />HIP <br />-35.94 <br />-49.57 <br />-49.57 <br />-49.57 <br />10 <br />GABLE <br />-38.22 <br />-38.22 <br />-60.99 <br />-60.99 <br />-60.99 <br />-78.58 <br />r <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />r <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />(D (D <br />SHINGLE: Y11s' EXP. 1 CY16) or 1V32" EXP. 1 03 /16) <br />TILE: %2" EXP. 1 (3�/16) <br />r <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y$' x 0.113") NAILS <br />3r 3r �r <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1 Y32", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2'Y2" x 0.131 ") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE <br />ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />[4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />2x STUDS @ 16" O.C. <br />W/ SIMPSON SP1 W/ (10) 10d <br />NAILS AT BASE & SIMPSON <br />2x BLOCKING <br />SP2 w/ (12) 10d NAILS AT TOP <br />2x BLOCKING BETWEEN STUDS <br />TO TRUSS W/ (2) 12d TOENAILS <br />EACH END ( BETWEEN TRUSSES <br />(2) 12d NAILS TO EACH VERTICAL <br />LOW ROOF/WALL <br />STUD) <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />2x BASE PLATE W/ (2) 12d <br />NAILS @ 16" O.C. ALONG W/ <br />SIMPSON MTS12 W/ (14) 10d x <br />1 1/2" NAILS TO BLOCKING <br />BELOW @ 16" O.C. <br />LOW ROOF TRUSS W/— <br />RAISED BOTTOM CHORD <br />EXTENSION SEE TRUSS <br />S6 MANUF. SPEC'S FOR <br />CONNECTIONS TO G.T. <br />TYP. U.NO. SECTION <br />SCALE: 3/4"=1 F-0" <br />V <br />@ 24" O.C. <br />MIN. (2) <br />STRAPS <br />BLOCKING <br />L (2) 2x6 BLOCKING UNDER <br />2nd FLOOR WALL w/ <br />SIMPSON LUS24-2 w/ (16) <br />16d NAILS AT EACH END <br />BUMP OUT 3g <br />PLYWOOD <br />FLOORING <br />FLOOR G.T <br />SEE PLAN <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 -10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 -10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 1Cd x 1 1/2% 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dx1-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26)10d x1-1/2 <br />K <br />HD313 * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 *` <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8 - 10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 -16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR wl 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" HTS 20 1310 1245 24-10d x 1 1/2" HTW20 1530 1285 24-10d x 1 1/2" <br />SP1 555 535 10 - 10d SPT22 735 8 -10d <br />SP2 1010 1605 12-10d SPT24 1090 12-10d <br />HCP2 590 1 555 12-10d x 1 1/2" HHCP2 1 680 570 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L 1480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (* ). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 O <br />INTERSECTIONS. SPLICING 12 <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />OF <br />(A) <br />OR 2 PLY <br />;ARRIER <br />CONT LEDGER (A) <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />FLOOR FRAMING PLAN - ELEV - B <br />SCALE: %4"=V-0" <br />C*-4 <br />0 <br />CV <br />U1 <br />C2 <br />n <br />D <br />W <br />� <br />o <br />o cc <br />u i <br />W V <br />N <br />cm <br />LLa''�. <br />T o <br />y a o = <br />= <br />C <br />co a s W <br />wa <br />3 3 <br />o <br />E <br />'$ o <br />CL c.k <br />,o <br />FiS <br /><��Q��gse�r4RaiIItkfl��O,Sf <br />. <br />ryy . <br />Q -� <br />°. <br />PLO('- <br />.......... <br />To the best of the Enginee s knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />go <br />d E S w <br />M8�� <br />N <br />rs <br />N , CM <br />8,r <br />0 <br />7 Cn CO N LL LJl. <br />m <br />core W <br />a <br />M w a i <br />LL o z <br />LL Z <br />_ <br />Z <br />CIJ C ° o <br />mo 0 � <br />j'@NCO m <br />W <br />J Q <br />info~'°' ¢ z <br />z IL <br />IL <br />LO Cl) Z O <br />H <br />N <br />O U ❑UU <br />Z <br />W <br />V M � <br />z N M <br />o <br />U) <br />N <br />r� <br />V) <br />z <br />to 0 <br />LL <br />4-, <br />- <br />v <br />� <br />m <br />U <br />O <br />V) <br />v{(J <br />w o <br />L N <br />U) <br />U <br />w <br />J <br />r— J E <br />� 8 <br />p N <br />• <br />Y <br />Q <br />o <br />J <br />� <br />w <br />M <br />O <br />�Z <br />U- <br />E <br />zo <br />2z <br />s <br />z <br />a p <br />ca V <br />s1 <br />0 <br />❑a <br />FC6 CI <br />o <br />Zoe <br />d <br />100z <br />ao <br />wz <br />cn <br />z z <br />.a <br />o� <br />w <br />Q 0 <br />O, <br />ZF <br />z <br />m J <br />wo <br />OW <br />aw <br />� m <br />o <br />W <br />3 <br />T <br />C7 <br />2< <br />�� <br />�w <br />=r <br />m <br />0 <br />a& <br />r <br />3 <br />J <br />o <br />Jz <br />w� <br />T 01 <br />io <br />a <br />'fit <br />ZI1 <br />�U <br />O <br />J <br />> Lo <br />0 <br />Nt <br />rn <br />co <br />m <br />C� <br />L <br />M <br />L— <br />r <br />L0 <br />^ <br />C). <br />Co <br />r— <br />U) 2 <br />3: <br />N <br />CO <br />L0 <br />M <br />CIO <br />C) <br />C:) <br />LO <br />r <br />Q <br />cfl <br />It -- <br />r <br />Z <br />T <br />co C` <br />o <br />W <br />co <br />6i � <br />Z <br />Z <br />E T-- <br />E <br />w <br />c`o <br />C <br />t0 <br />a <br />1 U -j <br />¢ p <br />C <br />JOB <br />NO : <br />23-06109 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />6.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.