Laserfiche WebLink
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load . O <br />Safe vertical load Safe horizontal load - <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />- r -•_ ; A k•_ ; FORM dt GROUT SOLID <br />ll' <br />8F8-16/1T 8F8-0B/1T 8RF6-0B/1T ;'�, p W <br />8RF14-1B/1T8RF14-0B/1T 81716-OB/11T 8F16-1B/11T 80 #5 BAR CONT. <br />81=20-013/1 T <br />® "V" LINTEL DETAIL <br />l9 r CM SCALE=N.T.S. <br />I <br />I <br />TYPE DESIGNATION <br />F = FILLED WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />J <br />6 F 16- <br />B/ 1 T <br />U <br />a <br />00 <br />tNOMINAL, <br />QUANTITYOF <br />N <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />#5 REBAR ALTERNATE POWERS <br />MIN. (1) REQ'D <br />CLEAR STEEL LINTEL <br />° <br />= <br />C7 <br />a <br />G <br />M.U. <br />#5 REBAR AT TOP <br />w <br />°� <br />MIN. (1) REQ'D- <br />2 <br />° <br />a <br />° <br />z <br />° <br />° <br />GROUT <br />� <br />, <br />_ <br />h <br />° <br />Q (r <br />5 REBAR AT <br />= co w <br />BOTTOM OF <br />t- U)- W <br />O0 U <br />"W-BOTTOM <br />LINTEL CAVITY <br />0 V >< ud <br />REINFORCING <br />PROVIDED IN <br />0 ¢ Cj <br />Q LL O 0:z <br />Z- p w n <br />_ <br />7-5/8"ACTUAL <br />8" NOMINAL WIDTH <br />LINTEL <br />O 0 <br />(VARIES) <br />cn a Cr a `✓ <br />1-1/2" CLEAR <br />MATERIALS <br />16 GAUGE POWERS <br />cTf precas intels = 3500 psi. <br />STEEL BOXED LINTEL <br />2. f c prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />ONLY IF NOTED ON LINTEL PLAN <br />minimum net area compressive strength = 1900 psi. <br />1. Refer to manufacturer's specifications for installation. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />2. Contractor to provide proper protection of lintel too prevent rusting. <br />7. 270 low relaxation. <br />Refer to manufacturers specifications. <br />7132 wire per ASTM A510. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />S. Mortar per ASTM C270 type M or S. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />applying the cementitiuos coating. See contractor specifications <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />----STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />2x8 #2 SYP STUDS @ 8" O.C. W/ (2) USP OR <br />SCHEDULE <br />SIMPSON MSTAM36 STRAPS EACH STUD ((1) <br />STRAPS EACH SIDE) CENTERED W/ (13) 10d <br />NAILS & (8) Y4"x1 J" TAPCONS OR TITENS <br />*CENTER OF STRAP @ T/WALL TYP. U.N.O.oL <br />SEE PLAN <br />II <br />T/VVALL <br />2x8 #2 SYP P.T. BASE PLATE <br />W/ y" EPDXY ANCHOR OR Y2" <br />J BOLT W/ MIN. 7" EMBEDMENT @ <br />g" KNOCKOUT COURSE <br />32" O.C. & 6" FROM EACH END <br />= I f <br />W/ (1) #5 CONT. <br />SEE PLAN FOR FILLED CELL <br />SPACING <br />= E <br />O <br />1 <br />WALL SPLICE DETAIL 8'-0" LL <br />REVISED: 11/04/19 SCALE: 1" = 1'-0" <br />O <br />4'-6" LL <br />O <br />4'-6" LL <br />B <br />MIN. <br />5'-8" LL <br />O O <br />13'-0" LL 5'-10" LL <br />E <br />MIN. <br />17'-4" LL <br />LINTEL PLAN - ELEV-A <br />SCALE: Y4"=1'-O" <br />e+n <br />N <br />N <br />0 <br />c <br />O <br />o <br />J <br />o' c <br />� <br />u a <br />c ca c, <br />•- c " 0- <br />N y C7 <br />Q N Y <br />o� d <br />E G <br />y o Q <br />cr_ ti <br />> c c <br />N fG A <br />7 <br />N Q- <br />c E <br />CcC> <br />d. J <br />=at!t+a <br />Ch <br />CV <br />' <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers <br />signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a <br />E <br />co <br />0 <br />coo, c o <br />c0 C N_ <br />�� # <br />r <br />Q <br /># LL <br />LL <br />J LL U_ LL <br />n <br />Z <br />m c v 77g 5 <br />_ <br />0 <br />W N O <br />o <br />0�rn°' m <br />Z <br />LLW <br />Co 0 <br />LO N Z co Q J <br />Z <br />N <br />OU 0 <br />W <br />❑ ❑ <br />(D <br />CD <br />z N M <br />o g <br />z N <br />z o � <br />� <br />N <br />z <br />CD o <br />cl <br />1 ' <br />LL <br />y <br />T <br />n <br />W N <br />� m <br />U <br />C) O <br />o0 <br />^ <br />tI!^! <br />w <br />C N <br />v' <br />� <br />to <br />to <br />~ <br />U ai <br />� - E <br />_ � 8 <br />I <br />= w <br />U 'o <br />U) <br />d 0 <br />ts, <br />.4 <br />~ <br />0 <br />Z <br />is <br />_l <br />o <br />Z <br />Z <br />LL <br />E <br />z <br />> ry <br />CI_z® <br />p <br />E U <br />E <br />oa <br />Im n7 <br />E �-' <br />U O <br />� � <br />p¢ <br />ao <br />o� <br />Qz <br />Z <br />� <br />O <br /><o <br />�m°� <br />p U <br />mo <br />Z <br />Z <br />r <br />�o <br />U <br />W <br />`� <br />° <br />�w <br />m <br />� <br />0 <br />oLL <br />J <br />3. <br />< <br />O <br />a3 <br />2 O <br />0 <br />= <br />>M <br />O <br />c� <br />co Lr) <br />r <br />Cr <br />c <br />T <br />� <br />Y <br />(n o <br />N <br />m <br />_ <br />LO <br />co <br />CD <br />04 <br />0) CD <br />LO <br />N <br />Q <br />d LO <br />r <br />LO <br />E <br />4 <br />M <br />v; to <br />o <br />Z <br />Z <br />E <br />c <br />d <br />E <br />U <br />Q p <br />3 <br />JOB <br />NO: <br />23-06111 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />