36469 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36469 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 2:02:04 PM
Creation date
2/19/2025 10:02:40 AM
Metadata
Fields
Template:
Building Plans
Street #
36469
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6598
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I 11 <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH WALL SHEATHING <br />16GAx1-1\2" LONG (3/4"-1"CROWN) ItMAX1,4 I I� 16GAxl-1/2" LONG (3/4%1" <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />"DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH" <br />"ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" a - <br />0 <br />STUB -OUT FOR O 1'-O" o a icy <br />GAS METER qW U <br />O <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8"or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8"gap --i <br />FILL CELL—\ STD. 90' HOOK i— BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />w (� NAILS TYP. GIRDER TRUSS <br />a STD. 900 U CONT. #5 <br />BAR CONT.5 > I HOOK BAR 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN —PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND % �� SHEATHING PER PLAN <br />CONNECTION / <br />TJI TO BE CUT TO ALLOW <br />�\ <br />FOR BLOCKINGII-JI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />i 1/8" min. ) Small gap 2" min. <br />i 2" max. 4" max. Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />& 9-1/2" 2-8dd2-8d <br />BCI 5000s <br />_ Series Depth End Intermediate <br />11-7/8" 2-8d� 3-8d <br />Clinch nails / / - 14" 2-8d 5-8d <br />- -- ---- _ <br />when 9-1/2" _ 2-8d 2-__ <br />- - <br />BCI 6000s®i _1 1-7/8" 2-8d 3-8d <br />possible `• ® 11 2-8d <br />.BCI 6500s <br />16" 2-8d 6 8d <br />1) <br />Support back <br />ck of web during nailing to prevent damage to <br />11-7/8" <br />8d <br />3-8d <br />web -flange connection. <br />�'r <br />O <br />BCI 60sR 6" <br />12 <br />2-8a <br />5-8d _ <br />2 <br />Block solid between joists for full length of span. <br />g p <br />Tight fit - <br />g <br />6-8d <br />gap p g p g <br />2x4/PI ood/OSBwebstiffener <br />4" <br />2x <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or max. - 16' 6-16d i 6-16d <br />OF THE JOIST ASA REQUIRED LEAVING)/8" GAP @ TOP sides by 6". - Hangers with side nailing. <br />-Hangerswithsidesnotcontaining WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - <br />Uidsm ut cuts.l /I d N.T.S. <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer <br />=1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />de f r a ro ri to <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />C Looaad�bearing walls <br />co o pp p a �i <br />details in One 10d box -� - <br />areas=20 of high or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />Provide adequate bearing <br />for each lapped joist. <br />10d nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />n ern oor co umn w oa s <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />CD <br />IlAt CID <br />rk <br />6„ A 1Yz" ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS, <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />F( rid Hate g"%e n <br />2 <br />3 <br />4 <br />5 <br />16 <br />7 <br />8 : <br />&87 <br />tt} <br />11 <br />12 <br />13 <br />Plectanm1w Fite Side ft <br />2 <br />3 <br />6 <br />6 <br />8 <br />10 - <br />Any 16" joist <br />Span (ft) <br />8 <br />V-0" <br />V-1" <br />1' 2" <br />V-2" <br />V-3" <br />V-3" <br />1'-T' <br />V-11" <br />2'-4" <br />2'-9" <br />3-2" <br />3T' <br />12 <br />T-0" <br />V-1" <br />T-2" <br />V-2" <br />V-3" <br />V-9" <br />2'-4" <br />2-11" <br />3-7' <br />4'-2" <br />4'_9" <br />6-4" <br />16 <br />V-0" <br />V-1" <br />1' 2" <br />V-2" <br />T-T' <br />2-5" <br />3-2" <br />3-10" <br />4-9" <br />5'-7" <br />6-4" <br />T 2" <br />20 <br />1'-0" <br />1'-1" <br />1' 2" <br />1'-2" <br />2-0'" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6'-11" <br />7'-11" <br />8'-11" <br />24 <br />1 1'-0 <br />1'-1" <br />1'-2 <br />1'-3" <br />2-5" <br />3-7' <br />1 4'-9 <br />6-10" <br />1 7 2 <br />8'-4" <br />9-6" <br />1 10'-9 <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Yi' ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />5/8" 0 <br />THRU <br />BOLT <br />I.0 <br />SIMPSC <br />w/ (22) <br />NAILS ? <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />10 1 <br />Backer block (12" wide min.) \ �-10d nails.Nail with 10 I I II I I —I <br />Install tight to top flange.SLEEVE THRU STEM .•. . :•../ SEE PLAN FOJoist hanger aFOUNDATION INFO_ <br />a <br />STEM FOUNDATION <br />\ it Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />+ 1/4"-2" gap <br />f - <br />l - Backer Block I <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />�I requirements <br />f% jr 0.6 X Joist <br />" depth <br />z- <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE REINF. SEE PLAN <br />E--4 n <br />1-1 I I-1I1=1 <br />° llillll ICI—' <br />° — <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />l HTS INSTALLATION <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE <br />PENETRATION <br />a a <br />1-1I1-III-II\IN <br />IIIII• <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />op <br />I-111-Ill , = <br />d <br />v° <br />i 11 <br />• <br />IIIIIIIIII'III <br />, <br />SEE FND. PLN. <br />SIZE & REINF. <br />-12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' 0"—\ <br />CENTERED @PIPE <br />PENETRATION <br />O ° A <br />PVC OR SCH40 SLEEVE <br />r— PLUMBING LINE <br />d L <br />° <br />z •a • <br />io <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. _ _ a aw <br />as III11-1 I ElI I I- <br />1=1 I I— a <br />i <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />e� <br />C= <br />CV <br />160 <br />.s <br />o d , <br />9 W <br />O � <br />O <br />N <br />-�mX <br />=LLa. <br />N O � <br />Vi 9 N t <br />N O <br />> E s c <br />d C, w a <br />� <br />3 � <br />3 •- <br />V7 Q .C7 <br />E <br />a <br />� v <br />0 <br />,p <br />i e <br />r• <br />' <br />-r /!lfj,•ftt !: <br />! 6i <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W V Ep <br />a M8 <br />O N <br />N <br />N <br />V M O <br />0 <br />0) <br />N C14 c <br />Q <br />a a <br />a Y <br />J u_ U. <br />z <br />Zc� <br />0 <br />Y m o <br />doe <br />0 5 0 <br />�' 7 N (V <br />0 <br />m J Q <br />_� <br />Win�pjQ' <br />< r z <br />_' N M Z <br />LL_ <br />W <br />U 0 <br />0 <br />f=- <br />0� <br />Z <br />❑❑❑ <br />W <br />URI <br />z N <br />_ a o <br />� <br />N <br />(D � <br />QE3 <br />�r <br />V I <br />U) z aC3 <br />0 <br />4-1 cn <br />(u w <br />a <br />U <br />0 w o <br />N_0* N <br />N .) <br />=, <br />U <br />W J <br />w ro <br />v o <br />c M <br />• <br />�® <br />Q N 0 <br />seo <br />o <br />C <br />w <br />_ <br />J <br />o <br />z <br />z <br />U_ <br />Ep <br />z o <br />>m <br />aN <br />CL <br />N U <br />wo <br />sF <br />z® <br />H <br />70 <br />< <br />wa <br />�o <br />O L <br />a i <br />0 L <br />d z <br />Z <br />0 <br />L <br />w p <br />z <br />w J <br />mo <br />z_J <br />¢ <br />z <br />o Q <br />g o <br />W <br />cn <br />w <br />" z <br />m <br />ow <br />= 3 <br />F <br />v <br />ola <br />° 3 <br />C <br />o CD. <br />>M <br />O <br />N <br />d. <br />T <br />^ 'T <br />L , <br />Cr >, <br />T <br />Q' <br />= <br />co <br />IL.n <br />~ <br />0 N <br />o <br />O <br />Lin <br />0 <br />Q CD N <br />T <br />6 <br />T <br />Y c'M M <br />o <br />Z <br />f6 <br />N to <br />Z <br />E r <br />c <br />at�0 <br />cc� <br />Q <br />JOB <br />NO: 23-06111 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />