Laserfiche WebLink
CROSS BRACING DETAIL (TYP.) <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CON1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY B FRAMED RIDGE <br />MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. DB <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP. TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />�3 <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />w CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE EXTEND <br />FOUNDATION PLAN SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />4" <br />#3 STIRRUPS AT 4'-0" <br />TWHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />- • CV z <br />1'-4" <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />T T <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"0.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT-j CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL a@ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />2", <br />----------*- - <br />w <br />4" Z <br />PORCH SLAB SEE a N <br />FOUNDATION PLAN Iw <br />U) 2 <br />z <br />W/ #3 STIRRUPS AT �, z <br />4'-0" WHEN DEPTH '- <br />EXCEEDS 30" LOWER OR <br />GARAGE SLAB <br />V-4" SEE PLAN <br />AL <br />LARGE STEP DOWN-1-7 <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />2X4 STUDS w/ SIMPSON <br />SP1 w/ (10) 10d NAILS <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A —A <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER PACK <br />USSES HIP <br />SIDE OR BOTH IF REQ'D) G.T <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />WOOD POST. SEE FLR__T <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />EXTEND <br />- -=-s-- =-= SLAB 1 1/2" <br />'k <br />(2) #5's CONT. T&B w/ <br />4„ <br />_ #3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE WHEN DEPTH <br />FOUNDATION PLAN EXCEEDS 30" <br />GRADE <br />•. N Z <br />1'-4" <br />2 ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY <br />INTEGRATE MASONRY ABOVE MASONRY <br />I KNEEWALL INTO CMU BASE OR PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF PLAN FOR COLUMN <br />REQUIRED INFO <br />1 MASONRY KNEE WALL MAX 3 1 1 <br />1 COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 I 1 <br />z <br />O <br />Q <br />w <br />w <br />w <br />U) <br />Sk <br />1 <br />1 <br />w/ (1) #5 CON <br />1 <br />1 <br />REQ'D @ MID <br />1 <br />1 <br />1 <br />I <br />1 <br />I <br />II 1 <br />1 <br />I I <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />T. FILLED CELL VERTICAL EACH <br />SPAN MAX 6'-8" CORNER FILLED I 1 <br />MAX 3 SOLID. SEE ELEV.Ak j <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY <br />1 1 <br />-�---- X_- Y-` ,-- 1 <br />.,. .. r a <br />SLAB PORCH SLAB SEE <br />50 <br />LEVEL FOUNDATION PLAN <br />(2) #5's CONT T&B w/ - z <br />CONTRACTOR TO INSTALL SEE CUT • �" <br />MIN 3" x 3" WEEP HOLE SECTION FOR #3 STIRRUPS AT 4'-0" '- <br />ALONG w/ PITCHING SLAB MORE INFO WHEN DEPTH <br />EXCEEDS 30" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TI E <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />-------� _______ <br />CONTRACTOR TO INSTALL SEE CUT • �" <br />MIN 3" x 3" WEEP HOLE SECTION FOR #3 STIRRUPS AT 4'-0" '- <br />ALONG w/ PITCHING SLAB MORE INFO WHEN DEPTH <br />EXCEEDS 30" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TI E <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />#5 REBAR CONT <br />@ SLAB LEVEL <br />EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />-------� _______ <br />-- L.SEE PLAN L. <br />I SIMPSON HUC410 w/ (14) <br />FOR CANT. <br />16d INTO HEADER & (6) <br />I 10d INTO BEAM - SEE <br />I <br />I ROOF PAN FOR MORE <br />I I <br />I INFO <br />I <br />I <br />I SEE FLOOR PLAN FOR <br />I l <br />I <br />COLUMN SIZE & BASE I <br />I I 7/16" OSB FLITCH PLATE <br />CONNECTION INFO <br />REQ'D ONLY WHEN <br />— — ---� <br />INDICATED ON BM. <br />L__- <br />_ <br />---_- _ _--- — SCHEDULE/PLAN <br />7/16" OSB FLITCH PATE <br />SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION A SC EDULDE/P ANM OPTION B CONNECTION INFO OPTION C <br />EXTERIOR SHEATHING <br />ATTACHED PER SEE ROOF PLAN <br />NAILING SCHEDULE FOR BEAM SIZE & <br />CONNECTION INFO. <br />2X4 BASE PLATE W/ <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2" NAILS <br />TO FLOOR GIRDER <br />BELOW @ 16" O.C. <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION aC� FLOOR <br />CONNECTION r22%N)II, <br />SCALE: N.T.S. <br />COMMON BM. TO POST ATTACHMENT rA� <br />SIMPSON (2) HTS20 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A F_� A <br />SEE PAN FOR <br />TOP OF BEAM <br />I <br />I <br />I <br />-J <br />SEE PAN FOR <br />CANT. IF <br />INDICATED <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />-TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL r7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. r. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d • <br />NAILS OR IF 2 PLY TRUSS SEE FLOOR FRAMING PLAN <br />SIMPSON LUS26-2 w/ (8) 16d AND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = 1' -0" <br />Y2" CDX PLYWOOD OR %6" O.S.B. <br />SHEATHING REQ'D FROM BOTTOM <br />OF WALL TO ROOF SHEATHING <br />ABOVE W/ 8d NAILS @ 4" O.C. IN <br />FIELD, EDGES & BOUNDARIES — <br />COMMON TRUSS <br />W/ INTERIOR BRG. <br />SEE PLAN FOR <br />CONNECTIONS <br />INFO. <br />- - RUSS/ <br />OP WAL <br />`FSEE PLAN <br />MIN. (2) 2x8 #2 SYP <br />HEADER. SEE Q/S4 FOR <br />REQ'D CONNECTIONS <br />2x4 #2 SPF STUDS @ <br />12" O.C. W/ USP SPT22 <br />@ BASE & SPT24 @ <br />TOP <br />I <br />2X4 #2 SYP P.T. PLATE W/ <br />6/" EPDXY ANCHOR OR <br />2„ J-BOLT OR Y2 TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />SEE PLAN MAX. MIN. 6 EMB�CPI <br />24" STEPS <br />e <br />SEE PLAN FOR OPT. <br />STAIR INFO. IF <br />CONCRETE STAIRS a d. <br />FORMED & POURED MAIN HOUSE <br />SLAB <br />W/ (1) #5 EACH STEP a <br />d Q'. <br />(2) #5's CONT. T&B <br />W/ #3 STIRRUPS AT <br />d 4'-0" WHEN DEPTH <br />:a'd. 8 _da ° EXCEEDS 30" <br />GARAGE OR "' z <br />LOWER SLAB <br />SEE PLAN <br />1'-4" <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />M <br />N <br />C <br />N <br />Ln o <br />® d <br />9 W <br />� >z V_ 15 o <br />— m <br />a <br />N 14 ® d <br />.N y O f0 <br />d N Y <br />d -E <br />f <br />3 cc <br />i d d.0 <br />�. d <br />� T <br />E <br />2 o <br />a. <br />��F�aaaaall�lsa��i<�� � <br />C. d. <br />O Y ` <br />E Ci <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />f. o E <br />.! o co 8 <br />�y r;{2' V co C N t` <br />7x C E— o; Go <br />N Go <br />C a . <br />.zri ;• � N � # W <br />03 J LL W <br />k �a�� mLL� 5 a <br />I, (� W <br />Z — 'O IL <br />Y <br />fSo 8 <br />� co N c0 O O <br />W ) rnrn r <br />W cn m <br />+ }a Z � co Z <br />L� (� N Q O O <br />Z O U 0 Cn <br />❑ ❑ <br />V M <br />Z N C7 <br />00 <br />Z N <br />Z n <br />rZ woolm <br />— N <br />M <br />(Do <br />N—v 0 -+ <br />N <br />w <br />U <br />0 <br />-ro <br />� � in <br />QE 1 <br />Q N �® <br />o <br />w <br />M Q <br />U_ =o >m <br />e E oo Z" <br />O <br />E V w �a <br />of 10X< <br />co az wz <br /><o �J <br />om� <br />ai C F O <br />Q p <br />M O Y Z F <br />m Nm <w <br />og go <br />men V� a Z <br />NZ <br />K O H <br />�w x <br />o wQ ;o <br />M d F <br />v zl¢ 00 3 <br />2(-) <br />= <br />> Ln _J <br />0 °' <br />rn <br />c� <br />Ln <br />r <br />Ln Ln <br />Co <br />U) o N <br />� m - <br />-_ L0 <br />� 0 <br />M co O <br />r\ C) LAC) <br />T Q � T <br />w LO <br />M o <br />L Z <br />z E T- N M <br />E � <br />a U Q p <br />JOB NO: 23-06113 <br />SCALE: AS NOTED <br />SHEET NO. <br />D 1 <br />