ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />& Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />h SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />❑0 HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />E TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />�P PUSH BUTTON SWITCH (OPTIONAL) <br />De PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />M ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T J OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A <br />INDOOR <br />PANEL <br />CENTER <br />3 <br />\ <br />#14 to lights &outlets <br />NEMA 1 10 #12 to appliances and GPI <br />--- -i__ <br />150 AMP/ <br />200 AMP 10 #10 to WH <br />} <br />00 #8 to Range <br />10 #6 to H VAC <br />MAGI N <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />'150=2/0 <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />GFII <br />a--,, <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS — <br />■---- LANAI <br />---- <br />I <br />I I <br />I I AC PAD <br />CFI GFI DISC. <br />I ❑� <br />• • • • • • <br />I <br />DINING <br />5'-0" <br />LIGHT AS PER <br />SPECS <br />PENDANT <br />- LIGHT PER <br />- _ SPECS <br />GREAT RM <br />�-- -�. I GFIII 2 <br />U.C. OUTLET ROUGH -IN [r <br />3; . ao FOR OPT. <br />4 Y I (/T <br />J FAN/LIGHT <br />o <br />�z- 1IGF I <br />1� <br />I I SWITCH FOR OPT. CLG. FAN/ <br />DISPOSAL `LIGHT PRE -WIRE <br />II <br />XXM <br />N 1°-10 <br />/ 1 <br />a t 3 <br />- �H ItJJ <br />M <br />_ F-7 — -- — W <br />T L HS I I <br />7 <br />C.) 1 HIAB II <br />�� GFI @ 44" <br />�/ <br />� <br />- - <br />W.H. / I A.F.F. <br />w Z <br />I I <br />11 Qp <br />� <br />J <br />1 <br />OCU=� <br />Zw I <br />>0co <br />-- <br />Da I <br />-- <br />-- <br />U Q <br />/ <br />cr GARAGE <br />- <br />t U LIGHT AS <br />w PER SPECS <br />> w GARAG E <br />GARAGE � / <br />DOOR <br />GFI <br />- <br />— — — — — — — — — — — — — — — — — — — — — — <br />ir� <br />I I <br />I IRRIGATION GFI I I <br />a <br />� <br />@ 44" A.F.F. <br />I 1 I <br />I I <br />I I <br />I I <br />I � I <br />------------------------------ <br />COACH LIGHTS <br />\ OR PREWIRE AS <br />\ PER SPECS i <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4"=V-0" <br />------------------I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />_BATH <br />I 1 <br />OPT. CLG. FAN <br />LIGHT PRE -WIRE / <br />BEDROOM 3 <br />OWNER'S <br />SUITE <br />/ /% \ <br />/ OPT. CLG. FAN/ <br />/ LIGHT PRE -WIRE <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L-------------------------------------J <br />n <br />VTR 3" VTR ICI, <br />III, I <br />�I I <br />I I <br />I I <br />I I <br />I r� <br />3" VTR III_ <br />I � I <br />I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN <br />SCALE:'/4'=V-0" <br />CV <br />C= <br />ego <br />kl> <br />s <br />o <br />W <br />j a ca C7 <br />� <br />--a�x <br />�® <br />N O <br />tL _ <br />3 � d � <br />tCD <br />u =� <br />ci a� <br />w en <br />�E. <br />Q <br />2Ca- <br />p <br />M <br />N <br />0 <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />g <br />W <br />1 <br />F- <br />v E o <br />o po <br />0o N U N @ <br />N m # <br />v <br />a � <br />9 j <br />o <br />.2—co U J <br />) C In� It <br />N <br />7 .d <br />CnNow- LL LU <br />b/ <br />s <br />a <br />a <br />LL a Z <br />J z <br />13 <br />< <br />N m O <br />;I <br />W <br />7@ (O J Q <br />rn J z <br />' <br />Z <br />LL <br />(o <br />W d <br />L0 <br />Cl) U CO m: <br />N Q <br />01 OE3O <br />fJl <br />z N M <br />0 0 <br />Z N <br />Q o Q <br />a <br />N� <br />z <br />a--+ <br />W CD <br />CD `o <br />� LL <br />LLJ <br />� <br />U <br />0, <br />N <br />0 <br />�N <br />s <br />U) <br />(J <br />J £ <br />_ _ 8 <br />�.... <br />�® <br />U o m <br />c U) Y <br />< <br />o <br />cfl <br />M <br />O <br />w <br />z <br />Q <br />�o <br />>� <br />ZN <br />ze <br />® <br />E V <br />o� <br />z <br />oa <br />H <br />�o <br />Uo <br />o E <br />o <br />0 <br />r � <br />co <br />as <br />i <br />z <br />Qo <br />a z <br />cf� t6 <br />c <br />¢o <br />Z <br />Y�z <br />wg <br />.0 <br />�? C <br />o <br />Z <br />m J <br />m <br />a� <br />aw <br />1Z <br />o< <br />go <br />rn <br />w 2i <br />a <br />nw <br />W <br />co�� <br />gz <br />J <br />=� <br />�5 <br />J <br />o <br />My <br />wa <br />oa <br />Yo <br />° 3 <br />p <br />J <br />'� <br />O <br />6 <br />rn <br />@ <br />0 <br />L_ <br />Ln <br />CID <br />r <br />:3Ln <br />L0 <br />Cr <br />Q <br />U) <br />CO <br />N <br />— <br />u <br />L <br />4l <br />`i <br />(0 <br />N <br />0) <br />O <br />I.n <br />T <br />� N <br />r <br />T <br />4i <br />w <br />M M <br />o <br />ca <br />7 <br />(A LO <br />z <br />Z <br />E r <br />N <br />cu <br />U <br />-0p <br />a <br />� <br />JOB <br />NO: <br />23-06113 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />-- <br />6 ITTi 7 i h. I k 11 1 I <br />