My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36491 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36491 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:09:09 PM
Creation date
2/19/2025 10:03:22 AM
Metadata
Fields
Template:
Building Plans
Street #
36491
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6610
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES. - <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqT <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4. FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />14) EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />[B] PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />19 ELECTRIC METER <br />WWI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />L J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANELCENTER <br />10 #14 to lights & outlets <br />NEMA 1 <br />00 #12 to appliances and GPI <br />150 AMP/ <br />200 AMP <br />01 #10to WH <br />10 #S to Range <br />#6 to HVAC <br />!R <br />MAOIN <br />150=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND Discot <br />SERVICE BY POWER CO. <br />INTERSYSTEM Bare Cu Ground <br />BONDING OUNDING WIRE <br />TERMINATION PER %1 WITH CODE APPROVED <br />NEC 17, 250.94 _/_J// CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1.5" VTR III 3" VTR <br />`III �I� <br />I <br />I I <br />I I <br />I � I <br />DEDICATED ' <br />RECEPTACLE FOR <br />MICROWAVE RANC <br />HOOD PER SPECS <br />1113" VTR <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />I SWITCH FOR <br />/ DISPOSAL <br />;I <br />J I <br />X a UC <br />I GFI <br />N I <br />Loj, <br />LGFI <br />°WII <br />\ L--� <br />� I <br />ITCHEN / <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />A/C PAD <br />DISC. WID <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />GFI <br />TO LIGH <br />AND <br />SWITCH <br />ABOVE <br />NOOK <br />r---------------------- <br />1 i enini I <br />G � <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE' <br />GFI SWITCH OR <br />DISPOSAL <br />FAMILY <br />I <br />PENDANT ROUGH -IN FOR <br />o\ I UC AS PER OPT. CLG. FAN/ <br />(�GF-I I SPECS LIGHT PRE -WIRE <br />Q I <br />LT <br />DWI IN, J <br />G <br />ITCHEN\ / <br />/ <br />REF W <br />LAU <br />GFI <br />CH <br />DINING <br />I <br />PENDANT AS ' <br />PER SPECS <br />1 <br />C.M. I <br />PWDR <br />1'I'I'I'IT I'I'I'I'I'I'I'I'I'I'I'I <br />uJ/url �W'+L+ GFI @ 44 1 <br />rr A.F.F. A.F.F. <br />w w <br />� Z� <br />}0LL <br />m I <br />=C) <br />> _j I <br />---------- \--------------------- <br />— � GARAGE <br />z w � ,.. <br />a / <br />FOYER - <br />1 <br />DB <br />\ I <br />I \ <br />I <br />WP ENTRY � <br />U Q L / GFI DB & GFI TO <br />LIGHT AS - I VERTICALLD <br />>_ Y <br />0 w PER SPECS / 9� I <br />> to <br />/ / I <br />GARAGE I <br />---------------0.00P---------------, <br />GFI I / <br />I IRRIGATION I <br />GFI @ 44" <br />A.F.F. <br />I I / <br />I I / <br />I I <br />I I <br />I I � <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - / <br />------------------------------ / / <br />(fX /6-- <br />COACH LIGHTS ZCOACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / / PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I <br />I I <br />I I <br />I I I <br />I I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —I <br />SECOND FLOOR ELECTRICAL PLAN <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />ELEV-B <br />,L <br />a+rs <br />ti <br />� <br />C <br />O <br />G W <br />Q <br />�O c <br />{O Q L <br />Gt V w <br />%�,�� <br />N b <br />c <br />C6 <br />b <br />M <br />O <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />� 94 <br />W <br />t <br />kid <br />E c N <br />8 cD n �ci <br />O N N � <br />00 (D ik l.L0) J <br />N <br />N <br />�rr it w w <br />a 11 <br />` <br />;t. :Q <br />�Mv W <br />c J Cc LLLL t1 Y r j <br />0 <br />Z <br />— 0. <br />m C O� O <br />s <br />2co ono <br />m <br />'O N <br />_0 <br />c0 Q <br />r-z <br />IL <br />ao O X O w <br />N M Z U U F <br />5'yf•5p w <br />U ❑❑❑ <br />Z <br />11 _, "`e h W <br />m <br />N M <br />O <br />Z N <br />� o � <br />Q s. <br />V^)' <br />Z a <br />`o <br />W <br />LL <br />LIJ <br />O <br />U c <br />oIJ.3 <br />'gw <br />8 <br />Ott <br />s <br />U o N <br />U)�� <br />t <br />r <br />o <br />Z <br />w <br />J <br />� <br />Z <br />a <br />� <br />a <br />ze <br />p <br />E CJ <br />ag <br />o a <br />t2 r0 <br />n <br />U O <br />�E <br />o <br />0 <br />O <br />o <br />C.0 <br />q p <br />o <br />¢� <br />�a <br />W Z <br />�w <br />YO <br />mo <br />ll <br />Zm <br />v <br />� � <br />om <br />¢`a <br />Qw <br />gZ <br />go <br />a � <br />� <br />to W <br />Wo¢ <br />as <br />� <br />= F <br />o <br />w¢ <br />;o <br />M <br />d <br />5 <br />_F <br />a4 'a 3 <br />> C'7 <br />O <br />@ <br />V <br />0 <br />^' <br />i <br />(ID Lo <br />r <br />Lid <br />U <br />(n 0 <br />m <br />N <br />- <br />LO <br />CM <br />� <br />7 <br />N <br />N <br />Q <br />r <br />rU <br />m <br />C T <br />M M <br />LO <br />o <br />Z <br />Z <br />E T <br />vi <br />m` <br />C: <br />CU <br />tl <br />U _j <br />Q p <br />J <br />JOB <br />NO: <br />23-06118 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />I r - - - - - - - 7T i m i rr_ - i - - T T- - -rr i r <br />