My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38100-38121 Fall Stone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38100-38121 Fall Stone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 3:07:53 PM
Creation date
2/19/2025 10:03:42 AM
Metadata
Fields
Template:
Building Plans
Street #
38100-38121
Location
Fall Stone Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G. F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />I� SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />—� FLUORESCENT LIGHT FIXTURE <br />O EXHAUSTFAN <br />;Q EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />DB PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />(-� USB TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�]M ELECTRIC METER <br />I ELECTRIC PANEL <br />J DISCONNECT SWITCH <br />Q, 19 <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L T J OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />3" VTR JIL <br />JIB I <br />I I <br />I I <br />I I <br />I I <br />I OPT. <br />i LAV LAV <br />I <br />HANSON <br />I <br />BOX 1 <br />I I 3., <br />I <br />LAV �\ W/C <br />1 3" SHOWER <br />TUB/ <br />W/C SHOWER <br />STUDOR F� <br />VENT DBL SINK <br />W/ DISP. <br />LAV I WIC <br />3" <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Riser Diagram <br />4 UNIT BUILDING <br />(2) 1532 UNITS & (2) 1624 UNITS <br />Q <br />800 AMP <br />O <br />TERMINAL BOX <br />O <br />TENANT PANEL w/ 150 <br />150 AMP <br />150 AMP <br />AMP INSIDE MAIN <br />O <br />O <br />150 AMP <br />150 AMP <br />O <br />O <br />150 AMP <br />150 AMP <br />GROUND <br />1/0 CU. TO BUILDING STEEL <br />C.O. <br />2" PVC CONDUIT WITH 2 #2/0 AL - 1 #1/-0 AL-1 #1 AL <br />TO POWER CO. 6 REQUIRED PER BUILDING <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17 LOCAL CODES AND THE LOCAL POWER CO. <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT j WP <br />GFI <br />iM <br />KITCHEN 1 <br />JFI O <br />-ttr----------- - ------ --- <br />- - - G F I - - - <br />- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />- <br />� I <br />I <br />- GREAT ROOM <br />�N,� /�>ROUGH-IN\ ❑ <br />FOR OPT. CH <br />_ <br />FAN/LIGHT 1 <br />- I <br />I <br />I <br />1 <br />/ <br />I <br />I <br />I DB <br />ENtRY I WPo- <br />LIGHT AS U GFI <br />PEAS1, PELCS <br />DB & GFI TO <br />----------- <br />BE ALIGNED <br />VERTICALLY i <br />O <br />C.M <br />1■[�Z►7�14� 1 <br />GFI <br />@ 44" <br />' \ <br />W.H. <br />A.F.F. <br />1 \ O <br />t <br />I <br />I GARAGE <br />I I <br />\ GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r- — — <br />I <br />— — — — — — — — — — — — — — <br />I <br />I _ <br />bz <br />I <br />a <br />I <br />a <br />I <br />� � <br />I <br />I <br />W <br />>W <br />I <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: Ya"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />� — —I <br />OWNER'S <br />BEDROOM <br /><�\ /_'>ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />J V <br />MMMMM <br />FI <br />0. BATH <br />a <br />BATH 2 <br />'_';�_17 <br />-----------I <br />I <br />� I <br />L JWIC <br />— — — — — — — — — — J <br />STAI <br />ULJ' <br />` <br />LOFT <br />C.M \ <br />S.D. � <br />I 1 <br />// TROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />\BEDROOM 2 <br />NOTE: <br />-INSTALL 2" CONDUIT TO METER CAN <br />-INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />2ND ELECTRICA <br />SCALE: Y4'=V-0" <br />O <br />L -UNIT-A 1532 <br />cc3 <br />�• <br />c <br />.Q <br />O <br />a w <br />'C <br />CC Lt N <br />-o x <br />N <br />61 C J <br />3 <br />a!` m d <br />E� <br />w <br />CJ <br />3 CU <br />d U <br />U CU <br />N O- <br />C E <br />� O <br />Q U <br />42 <br />N <br />N <br />0 <br />00 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers <br />signature and <br />seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N <br />W <br />a <br />E <br />O CD <br />M <br />V_ <br />cc"U <br />N <br />N CA <br />0 <br />N W <br />G <br />73 C9 <br />7 LL7 V) <br />(O <br />N <br />N <br />w�tia <br />04 v <br />a <br />C103�e <br />q <br />C J <br />J LL <br />_ <br />LL Lu <br />d <br />w <br />o <br />Z <br />warn <br />U) <br />rroo� <br />73 M <br />� <br />a <br />0 <br />W <br />I_ <br />�26_jO� <br />w <br />Z <br />L <br />u'4 N Cl) Z <br />m <br />N O <br />Z <br />U <br />< � <br />W <br />El El <br />Z N M <br />o o <br />Z � N <br />a <br />a <br />- <br />r` <br />N <br />M <br />z <br />0 <br />0 <br />4 <br />(U w <br />U <br />w o <br />{11t6 <br />v C <br />W J <br />U <br />V <br />Ca o N <br />c U) <br />00 0 <br />®0 <br />em <br />o <br />� <br />w <br />M <br />M <br />yr ¢ <br />o � <br />z <br />2 <br />J <br />m E <br />E o <br />w <br />f^ <br />X o <br />- OU <br />CD <br />ao <br />o< <br />aZ <br />o IT <br />ao <br />L <br />� <br />Y <br />mi <br />o <br />0, <br />N <br />ym <br />aw <br />z= <br />son <br />Q <br />NMEN <br />wLL <br />dz <br />�w <br />o <br />o <br />co <br />w <br />�O <br />a= <br />o T <br />rn <br />�' <br />ro <br />C'V <br />Cfl <br />L <br />co <br />CN <br />N <br />� <br />�- N <br />N <br />T <br />N <br />v, r A Y <br />00 <br />0 <br />N <br />L 0 <br />I=- <br />�' <br />C) <br />LO N <br />LO <br />r <br />T <br />ai <br />w T <br />00 <br />o <br />E <br />M <br />= <br />� O <br />N <br />z <br />z <br />E <br />a <br />c <br />cc <br />d <br />U _j <br />Q p <br />JOB <br />NO: 22-09475-09478 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />13 <br />III Illii �iid�l� III' �! I �� <br />F-- T--, r-T— i <br />
The URL can be used to link to this page
Your browser does not support the video tag.