Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />WALL SHEATHING <br />rlAc.'. C: I I I 16GAx1-1/2" LONG 3/4" 1r, <br />STAPLES @ 6" O.C. VERT BETWEEN CROWN) STAPLES / 6" <br />STUDS (NOTED THUS:—) - OFFSET I I I I I I O.C. VERT INTO STUDS <br />STAPLES BETWEEN STUDS AS SHOWN <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0° <br />TANK -LESS W/H <br />CORNER OF L� <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" <br />STUB -OUT FOR r 1'-0" 0 0 0 <br />GAS METER O o <br />_ U <br />O � <br />N oz <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />T-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />1514" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />wood <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />FILL CELLS ,—STD. 90° HOOK BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />w � NAILS TYP. GIRDER TRUSS <br />STD. 90° CONT. #5 <br />CAR T. <br />HOOK BAR 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # FLOOR <br />above to bearing below. STUU 2ndDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" max. 4" X. <br />Clinch nails <br />when �J <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />g required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flangeuthcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />I lsa 3" /1Od1 nails at 6" n c <br />ja �'/ Provide adequate bearing <br />j for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series th End Intermediate <br />�De <br />1/2" <br />2-8d <br />2-8dBC15000s®7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />�BC16000s® <br />IBC16500s® <br />I <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16 <br />2-8d <br />6-8d <br />FBCI60s® <br />11-7/8" <br />1 2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />111-7/8" <br />1 3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer � Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over t7_12_1 <br />1 <br />blocking and wall or beam below.* — — <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. kJoist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />WA t W J �1� <br />6" A 1%" ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Yz" <br />8 <br />T-a' <br />1 _1"• <br />2. <br />1! 2' <br />14 -3" <br />1`-3 <br />1 -Z'° <br />1 -l1 <br />2-4' <br />2-9' S' 22' <br />3 7" <br />16. jolstYv�--- <br />12 <br />T-0'° <br />(-1" <br />1 2 <br />1'--2' <br />1'-3° <br />T-9 12-4'° <br />2-11" <br />37 <br />4, 2, 4- <br />51-41 <br />(l" <br />1 _1,. <br />1 <br />1' 2' <br />1 7 <br />2- <br />3'- <br />3-1t1" <br />1' <br />6 Z <br />7-2' <br />20 <br />1,4 <br />1'-1- <br />1,_2° <br />1 <br />24' <br />3-0"4'-a'4'-10" <br />9-11"' <br />6-11" 7'-11,. <br />0-1111 <br />_,. -- <br />24 <br />E'-0 R <br />11_1,. <br />1,.2 <br />1.-3,. <br />2-T <br />3, <br />4,-, 'R <br />5'-16" <br />7" 2'® <br />8,-4' 9'-G' <br />18,-'" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2, TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Jc <br />5/81 <br />THRU <br />BOLT <br />I.0 <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />e° a <br />- .—X <br />00 <br />FINI$H GRADE <br />Backer block (12" wide min.) <br />Nail with 10- 10d nails. <br />Install tight to top flange. SLEEVE THRU�=iSTEM J ° <br />° . <br />SEE PLAN FOR °. a <br />� FOUNDATION INFO d' I .I <br />STEM FOUNDATION <br />GRADE REINF SEE PLAN <br />Filler block. <br />\ Nail with <br />10-10d nails. <br />Backer block required where top „ n� <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. ° MITI I=„ I i I, <br />1/4"-2" gap <br />1 ! <br />_ it <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiff ner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />II <br />- requirements <br />0.6 X Joist <br />o T`depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />rvu unmor_ ,+ rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />SIMPSON H10A ° <br />w/ (18) 10d x 1 1/2" ° <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />(WHEN <br />REQUIRED) <br />PLUMBING LINE <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE PVC OR SCH40 SLEEVE <br />PENETRATION <br />° d <br />d ° ° <br />1=I 11=1 11=1 I d. 4, ' ° P 1=1 11=1 I fI I ICI I I <br />d 1—I 1,, ; I 1- <br />li <br />i— SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'4' <br />CENTERED @ PIPE <br />PENETRATION <br />° <br />PVC OR SCH40 SLEEVE <br />1r__ <br />MBIN LIN <br />U G E—PLUMBING <br />Z • ° • <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />7 _ ° 'C . .d <br />d d as c <br />d <br />. a <br />d <br />111111111I �Illllllil <br />° <br />SEE F0. ND. PLN. <br />SIZE &REINF. <br />N <br />C® <br />CU -o <br />> Lu <br />o,L <br />% <br />,N.cao <br />d O <br />zz N Y <br />Q <br />3 m <br />Q <br />v � <br />3 cc <br />m W <br />d = <br />= •— u ao <br />> c o <br />N 6 <br />= E <br />o <br />� v <br />4 <br />•®�yM1v. ..,. <br />`. 0; <br />.... ........ <br />�%Rr0��SS,O°� <br />,11611Qt�r <br />t <br />,Ctj <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural <br />engineering portions <br />of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N <br />W <br />a <br />�E <br />oS <br />V <br />0 <br />o <br />n0) 00 ( N r <br />o? <br />N <br />N <br />10 IN 8� LL <br />4 <br />M cr <br />N J <br />C —J LL LLI <br />J� LL LL <br />_ w <br />— o a Y <br />Z <br />E0 <br />:E 'Co N O co o <br />W <br />0 2O6jO' m III <br />ZLL <br />;n <br />Ua <br />< otJr <br />Z <br />❑❑ <br />Z N M <br />z o � <br />J <br />V) <br />z <br />C4 <br />0 <br />LL <br />4-1 <br />f'Q <br />Cn <br />w <br />U <br />O <br />L'�y <br />S(0 <br />w o <br />U <br />w <br />J <br />L 8 <br />U o <br />° <br />¢ 8 <br />m <br />O <br />cco <br />J <br />w <br />z <br />co <br />g <br />o <br />i <br />Q E <br />oo <br />ZE <br />aM <br />z® <br />Icu 6 <br />g� <br />g� <br />_° <br />0 <br />0 <br />O <br />O <br />H <br />w Q <br />z <br />a J <br />L <br />¢ z <br />U <br />m O <br />I <br />co J <br />� <br />0— <br />zo <br />�z <br />a <br />o� <br />a <br />�w <br />UJ <br />�j 3:ao <br />oW <br />w� <br />>° <br />CD <br />O <br />a <br />v <br />za <br />°3 <br />,o r <br />In <br />ui <br />rn <br />C'V <br />U <br />C0 <br />L <br />co <br />N <br />CD <br />N <br />N <br />TCr <br />N <br />U <br />V_ <br />in <br />LN <br />+-+� <br />M <br />O <br />LO <br />-0 <br />N <br />Q <br />_ <br />0 <br />N <br />O <br />T <br />r <br />E <br />r <br />C <br />00 <br />o <br />:3 O <br />N <br />z <br />`m <br />z <br />E <br />En <br />a <br />E <br />U � <br />Q p <br />_J <br />30B <br />NO : 22-09475-09478 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />T� lii I 1 F 7 f -F I -I <br />