1 1 ---1. 1 II , <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS. <br />1. Cut, fold up & temporarily secure weat <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING ­1 X <br />"" "' WEATHER <br />VE BARRIER & <br />tARILY SECURE <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHING <br />3/4"A" BEAD OF CONSTR. <br />SHEATHING <br />BY LAPPING DOWN <br />ADHESIVE TO BE APPLIED UNDER <br />OVER RIM JOIST AND UP <br />THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />Q <br />WEATHER <br />SELF -ADHERED FLASHING <br />RESISITIVE <br />BARRIER <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SUBFLOOR <br />ED FLASHING <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"A" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />° NAILING FLANGE SELF -ADHERED FLASHING <br />1 <br />DO NOT FLASH OVER 2 SEAL TOPS OF JOISTS <br />BOTTOM NAILING p UNDER DECKING <br />FLANGE O (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />8 2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in : 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />Al 11 <br />_V <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />NEEDED IN CORNERS RUBBERIZED ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />\ �o (BEFORE ELEASE PAPER <br />NG, SCORE <br />RRTO EXPOSE <br />ADHESIVE AS SHOWN) <br />0 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-7 Ground 7 <br />Water Resistant Barrier <br />SELF FLASHING <br />Lath <br />Ce <br />-ADHERED <br />PATCH <br />Sheathing <br />ee <br />tUCCO <br />r•K <br />S <br />� <br />° ° a <br />e <br />a <br />li <br />N <br />I, DOUBLE <br />1 ° a a ° <br />Ili JOIST <br />o n a <br />i <br />SINGLE WOOD BEAM <br />° <br />° <br />JOIST %% BELOW <br />t SELF -ADHERED FLASHING <br />Foundation Wall ° <br />< <br />SELF -ADHERED FLASHING 1 <br />a ° e 4 <br />a <br />2 <br />° <br />3" MIN <br />" <br />SELF -ADHERED SELF -ADHERED <br />4 <br />FLASHING FLASHING <br />a <br />Q <br />5 <br />SELF -ADHERED FLASHING <br />I <br />SELF -ADHERED FLASHING �' • <br />FOUNDATION WEEP SCREED • <br />DECK JOIST <br />OUTSIDE CORNER • <br />fl <br />I - <br />P <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8 <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1,1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as #Din each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to comer <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />With ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance With <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />With ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />`N� me WEEP SCREED DETAIL <br />NOT USED NOT USEDn ", NOT USED SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />-Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />c9 �' <br />zco <br />z� <br />a <br />C9 <br />Cl <br />v, <br />4--J ILLJ <br />� o <br />"O W <br />to <br />�Ln <br />fCT U <br />LU <br />p <br />t3 <br />o0 <br />m <br />M <br />C <br />������pypypy f7 <br />® <br />N <br />U <br />¢rn0 <br />rLL00 <br />al <br />�Rv <br />�o <br />BD� <br />j <br />I� <br />e <br />N N <br />i 0No <br />rn <br />Al Ez° <br />W Q 0 LL w <br />N <br />LY V4�'LLo a <br />LLmr8�U <br />Z <br />a <br />W N a <br />WWW.FDSENG.COM 0 <br />00 <br />N <br />0 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential ft Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />6vs! <br />' Q <br />a <br />�z 0 <br />g WZ/� <br />U) <br />J <br />Ov <br />N <br />/ <br />Q <br />LU <br />g® <br />U <br />tDC <br />n <br />0 <br />Z <br />Q <br />a <br />LL <br />O <br />3 <br />O <br />U <br />_ <br />`� <br />CL <br />LU <br />. <br />o <br />Ch <br />Q <br />Z <br />J <br />W <br />ILI o <br />Z 8 <br />�Ln-I <br />Z <br />�g <br />Z <br />y�j8 <br />I <br />r� <br />2 <br />Wu <br />.--� <br />a <br />0 <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO 4mO <br />SHEET NO. <br />W P <br />