My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39567 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39567 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:39:17 PM
Creation date
2/19/2025 10:04:38 AM
Metadata
Fields
Template:
Building Plans
Street #
39567
Location
Dawson Chase Dr
Contractor
Lennar Home LLC
Building Plans - Permit #
20520
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br />a <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL DETAILS <br />SN <br />STRUCTURAL NOTES <br />ABBREVIATIONS <br />SN1 <br />DETAILS <br />AB or A.B. Anchor Bolt <br />FIN FLR or FF or fin. flr. Finished Floor <br />PWDR or Pwd. Powder Room <br />S3 <br />DETAILS <br />ABV or Abv. Above <br />FIX or FXD Fixed <br />RA or R/A or R.A. <br />Return Air <br />S4 <br />DETAILS <br />AC or A/C Air -Conditioner <br />FLR or Fir. Floor <br />RAG or Rag. <br />Return Air Grill <br />ADJ or ADJ. Adjustable <br />FLR SYS or Fir Sys Floor System <br />RAD or Rad. <br />Radius <br />S5 <br />DETAILS <br />AFF or A,F.F, Above Finished Floor <br />FOM or F.O.M. Face Of Masonry <br />REC or Rec. <br />Recessed <br />SS <br />RETROFIT DETAILS <br />AHU or A.H.U. Air Handler Unit <br />FP or F.P. Fireplace <br />RECEPT <br />Receptacle <br />D1 <br />SECTIONS &DETAILS <br />ALT orALT. Alternate <br />FR DR French Door <br />REF or Ref. Refrigerator <br />BC Base Cabinet <br />FRT Front <br />REINF <br />Reinforcing <br />WP <br />WATERPROOFING DETAILS <br />BF B'rfold Door <br />FT or Ft. Foot/ Feet <br />READ or Req'd. <br />Required <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />BK SH or Bk Sh BookShelf <br />FTG or Ftg. Footing <br />RM or Rm. Room <br />BILK or BILK. Block <br />BLW or BLW. Below <br />GALV or Galy. Galvanized <br />GC or G.C. General Contractor <br />RND or Rnd. <br />RO or R.O. <br />Round <br />Rough Opening <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />PRODUCT APPROVAL NUMBERSS <br />BM or Bm. Beam <br />GFI or G.F.I. Ground Fault Interrupter <br />IRS or R/S or R&S Rod and Shelf <br />BOTorBot. Bottom <br />GTorG.T. Girder Truss <br />SO or SD. <br />Smoke Detector <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />BP or B.P. Bypass (door) <br />GYP BD or Gyp. Bd. Gypsum Board <br />SQ FT or SF or S.F. Square Foot (feet) <br />__- <br />BRG or BRG. Bearing <br />HB Hose Bibb <br />SGD <br />Sliding Glass Door <br />C Carpet <br />HDR or Hdr. Header <br />SH or Sh. <br />Shelves <br />CAB Cabinet <br />HGT or Hgt. Height <br />SHWR or Shwr. Shower <br />CIR or Cir. Circle <br />HH or H.H. Hand Held (plumbing faucet) <br />SHT <br />Sheet <br />�- <br />CJ or C/J Control Joint <br />HORIZ Horizontal <br />SL or S.L. <br />Side Lights <br />CLG or Clg. Ceiling <br />HS Hard Surface (flooring) <br />SPF or S.P.F. Spruce Pine Fir <br />J I—, <br />CMU Concrete Masonry Unit <br />ILO In Lieu Of <br />SPECS or SPECS. <br />Specifications <br />COFF or Coff. Coffered or Tray Ceiling <br />INSUL or Insul. Insulation <br />SQ or Sq. <br />Square <br />COL or Col. Column <br />INT or Int. Interior <br />STO <br />Storage <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />K/WALL or K/Wall Kneewall <br />KS or K.S. Knee Space <br />SW or S.W. <br />or S.Y.P. <br />Shear Wall <br />Southern Yellow Pine <br />ElmE] <br />OEI <br />❑ ❑ <br />CONN or CONN. Connection <br />LAUN or Lauri. Laundry <br />TB <br />TB <br />Towel Bar <br />CT or C.T.Cont. Continuous <br />CT or . Ceramic Tile <br />LF o L.F.L Lavatory <br />LF or L. Linear <br />TEMP or Temp. <br />or <br />TOB <br />Tempered <br />Thicken <br />❑ ❑ ❑ p <br />❑ IFElFE11 <br />D or D. Dryer <br />LL Lintel Length <br />a <br />.Thik'n. <br />TOB or T.O.B. <br />o <br />Top of Block <br />DB Door Bell <br />Laundry Tub <br />TOM or T.O.M. <br />Top of Masonry <br />DBL or Dbl. Double <br />M GT Management (room) <br />TOP or T.O.P. Top of Plate <br />F7 <br />DCF Decorative Cementitious Finish <br />MAS or Mas. Masonry <br />TP <br />Toilet Paper Holder <br />DEC or Dec. Decorative <br />MAX or Max Maximum <br />TR <br />Towel Ring <br />MDFEEFL7:1 <br />DED or Ded. Dedicated (outlet) <br />MC Medicine Cabinet <br />TRANS WDW or Trans. Transom Window <br />❑ E❑ <br />o, <br />DIA or Dia. Diameter <br />MFR or Mfr. Manufacturer <br />TYP or Typ. <br />Typical <br />-E! <br />DISP or Disp. Disposal <br />MW or MICRO or Micro. Microwave <br />UC or u.c. Under Counter <br />DIST or Dist. Distance <br />MIN or Min Minimum <br />UCL <br />Under Cabinet Lighting <br />DMF Decorative Masonry Finish <br />MIR or Mir. Mirror <br />UNO or U.N.O. <br />Unless Noted Otherwise <br />DS or D.S. Drawer Stack <br />MIL or M.L. Microlam <br />V or v. Valve (shower or tub/shower) <br />DTL Detail <br />MONO or Mono Monolithic <br />VB <br />Vanity Base <br />DV or D.V, Dryer Vent <br />NTS or N.T.S. Not to Scale <br />VERT or Vert. <br />Vertical <br />o <br />DVP or D.V.P. Diverter Valve (plumbing) <br />OE or O.E. Owner's Entry <br />VL or V.L. Versalam <br />DW or D.W. Dishwasher <br />OPNG or Opn'g. Opening <br />VTR <br />Vent through Roof <br />EA or Ea. Each <br />OPT or Opt. Optional <br />W or w <br />Washer <br />EW or E.W. Each Way <br />PC Pull Chain <br />W/ or w/ <br />With <br />ELEC or Elec. Electrical <br />PED or Ped. Pedestal <br />WC or W/C or W.C. <br />Water Closet (toilet) <br />ELEV or Elev. Elevation <br />PH Phone <br />WA or W.A. Wedge Anchor <br />°O <br />EQ Equal <br />PKT or Pkt. Pocket (Door) <br />WD or Wd <br />Wood <br />EXT or Ext. Exterior <br />PL or P.L. Parallam <br />WOW HDR or WDW. HDR, <br />Window Header <br />Q <br />EXP or Exp. Expansion <br />PLF Pounds per linear foot <br />WH or W.H. Water Heater <br />d- <br />FBC Florida Building Code <br />PLT HT or Pit. Ht. Plate Height <br />WIC or W.I.C. <br />Walk-in Closet <br />FDN or Fdn. Foundation <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />WM or W.M. <br />Wall Mounted (plumbing fixture) <br />FXD GL Fixed Glass <br />PSF Pounds per square foot <br />WP Water Proofing) <br />FG Fiberglass (Shower Pan) <br />PT or P.T. Pressure Treated <br />WS <br />Water Softener <br />FIN Finished <br />PW or P.W. Pre -wire <br />WWF <br />Welded Wire Fabric (Mesh) <br />x <br />N <br />a <br />REVISIONS <br />0 <br />0 <br />08-20-15 1.0 <br />NEW BASE PLAN <br />12-8-15 2.0 <br />ADDED VAULT. CLG. <br />12-28-17 3.0 <br />2017 FBC UPDATES <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />o <br />02-21-18 4.0 <br />ADDED GRADE BEAM 150 MPH ENG. <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />o <br />o <br />FOR 2 STORY HOMES <br />a <br />E <br />FT <br />THIS DRAWING AND DESIGN IS VALID <br />co <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />`g <br />CURRENT CODE IS VALID <br />i <br />EVp&ING <br />CODE REFERENCES ARE SUMMARIES <br />1L0 ISI <br />ISI��I <br />AqL <br />irl1E <br />CODE SECTIONS. <br />WORK gHP:I 4. COF <br />aka CO®E, <br />a_ <br />ALL 4 SUIL <br />ODE, <br />SEE FBCR (CURRENT VERSION) FOR <br />SE <br />V <br />CpDES <br />COMPLETE CODE INFORMATION. <br />OIL OF <br />Notice to Builder & All Subcontractors <br />THE <br />s <br />rn <br />0 <br />It is the intent of Designer/Engineer listed in the titlebiock of these <br />.CD o <br />-9 <br />documents that these documents be accurate, providing Licensed <br />a <br />`'1 <br />Qv <br />Professionals clear information. Every attempt has been made to <br />a� <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />��` ' �Ir � <br />,�� �'k''1. <br />�.�= <br />responsible for any errors, omissions,or misinterpretations <br />plan <br />o <br />undetected and not reported to the Designer /Engineer prior to <br />, <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />1941 <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />w <br />Payments will be made in accordance to the terms of the <br />agreement. <br />F <br />ULa <br />zC> <br />0 <br />o <br />z(.0 <br />N <br />z <br />Q <br />J <br />f � z <br />c) U' <br />a) u, <br />w <br />°V - <br />O'LJ <br />U <br />1- <br />m <br />w E <br />I.—M <br />p <br />a) <br />Eco <br />a M <br />_ U <br />O o 0 <br />U"-00 <br />C <br />o <br />o 0 <br />rn Q o <br />BD® <br />NC� <br />to <br />gMsN <br />N N <br />� <br />ZLU Ma�oZ <br />_ W <br />r N pQ C <br />� z <br />1Z0` <br />Ci �Q) < <br />a�• Cry <br />� <br />`� �N <br />e <br />�0..0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.