Laserfiche WebLink
02 <br />a <br />2 <br />E <br />0 <br />ti: <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 #14 Copper to lights & outlets <br />1 <br />20000 AMP <br />A <br />10 #12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O2/0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />`'G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />fLeph <br />� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />& <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PI H <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />T© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_ I <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. <br />GFI H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn DCD cocrc <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />vCI'(Ir T IVIC I CR <br />LOCATION WITH <br />BUILDER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Z m <br />_ o <br />ZCD <br />Z <br />Q <br />d <br />U)Ga <br />w <br />ro <br />�V — <br />O LU <br />M <br />I— <br />� a— <br />U <br />oh <br />m LV <br />W <br />I_ <br />co <br />CD M <br />0MU <br />WIN <br />[2 -O <br />O,o0 <br />UwL <br />�0 <br />Y <br />L <br />ao0a <br />Y I� <br />oC=) <br />rn Q o <br />B D® <br />4c <br />N �O <br />ra <br />W <br />iiN z z <br />'� Z <br />H a <br />I% s�o o ,j u- <br />LUQ y�M ' w <br />W y rnLL o a <br />a <br />0 Boa o <br />.m C N O <br />42 CAh <br />- <br />¢ <br />Wa <br />N¢M Q <br />O v U o <br />WWW.FDSENG.COM <br />0 <br />N <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Flodda Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />OZ <br />3� <br />�o <br />Z9 <br />J <br />ZB�� <br />Z <br />�-- <br />�Eowz <br />J <br />�0�co <br />co <br />V W W N <br />L <br />< <br />L.L <br />LU <br />Z O <br />aZ <br />z <br />W <br />Z <br />\ / <br />J <br />W <br />Z <br />O <br />O <br />9 <br />U <br />1'� <br />0 <br />0 <br />4 <br />.95 <br />Uw <br />14< <br />O� <br />N <br />r� <br />Q <br />Z<Z< <br />W <br />0o*o <br />Z <br />Z <br />•—1 <br />oo� o <br />r 0 <br />W <br />J <br />Ln <br />r-I <br />LJ.j <br />2: <br />Q <br />Z <br /><�Wo <br />g~o <br />N <br />Q <br />Z <br /><<O <br />Ln 0 <br />R o <br />W <br />O <br />UJI <br />= <br />. Z <br />aE <br />T__4 <br />a <br />to <br />o <br />SCALE : AS NOTED <br />DATE : 10/2/2018 <br />TECH: MJAMES <br />VERSION NO. 4mO <br />SHEET NO. <br />4.0 <br />I 1 11 1 r --f- 11 <br />